Computer-guided laser probe for ablation of brain tumours with ultrashort laser pulses.

A computer-guided laser probe has been developed for the application of ultrashort-pulsed lasers in neurosurgery. It is part of a novel operation concept for the treatment of deep-seated brain tumours. The system combines the positioning accuracy of stereotactic or neuronavigated instruments with the precise and therefore gentle characteristics of surgical lasers. The probe has an outer diameter of 5.5 mm and is directly inserted into the target volume. By a synchronized movement of three coaxial tubes, which guide the embedded optics, the laser radiation is focused at any time onto the current tissue surface. Since every single laser pulse has only a small effective volume of about 8 x 10(5) microm3, the application of a large number of succeeding pulses can be adapted to required geometries. Tissue fragments are removed from the growing operation cavity by continuous irrigation and suction through the laser probe. Blood vessels are detected by a confocal laser-scanning microscope, which is integrated into the probe, and can be closed by an additional coagulating laser. In this paper, the design and technical properties of the laser probe as well as its use in ablation and coagulation experiments are presented. A description of the overall operation system is given.

Animals↗

A Monte Carlo simulation of range for an invasive impedance respiration monitor.

One method of rate responsive pacing utilizes an analog of minute ventilation as the input to the rate control algorithm. A measure of the intravenous impedance along the pacing catheter is a convenient means of determining minute ventilation. Design of the impedance converter requires a knowledge of the range of DC and AC impedance signals. During normal and deep breathing, 116 AC measurements were taken from 34 Electrophysiology (EP) patients and 31 DC measurements were taken from 13 EP patients. The patient data produced skewed distributions with a normal AC mean of 0.45 +/- 0.40 ohms p-p, a deep AC mean of 2.0 +/- 1.6 ohms and a DC mean of 44 +/- 13 ohms. An eight variable static model was derived from prior work. Five of the physiological variables were chosen from established clinical ranges, one geometrical variable was chosen from prior work and two were selected by matching the statistics of a Monte Carlo analysis of the model with the statistics of the patient data. The blood resistivity was obtained from prior work. A simulation of 1000 measurements produced a normal breathing range of 0 to 2.24 ohms, a deep breathing range of 0 to 9.6 ohms and a DC range of 19 to 100 ohms.

Algorithms↗