PubMed Health⌕ Search

Biomedical subjects

S K Jani

Publications and source records attributed to S K Jani.

At least 19 recordsLinked to original sources

Radioisotopes and dosimetry in vascular brachytherapy.

This chapter summarizes the current status of available isotopes for vascular brachytherapy. The physics and dosimetric aspects of current and new sources would have a great deal of influence in the outcome of clinical trials and eventual success of brachytherapy in treating vascular disease.

Brachytherapy↗

Radiation safety of personnel during catheter-based Ir-192 coronary brachytherapy.

Catheter-based brachytherapy using Ir-192 seed sources has shown significant reduction in the rate of restenosis among patients with coronary in-stent restenosis. High-energy gamma rays from Ir-192 raise some radiation safety issues of personnel. The aim of this study was to fully analyze the radiation safety issues associated with Ir-192 brachytherapy in the cardiac cath lab environment. Measurements were made to assess the penetrating ability of Ir-192 gamma rays through tissues, concrete and lead. Radiation exposure levels were measured around a large number of patients undergoing Ir-192 brachytherapy. Personnel were carefully monitored for any additional dose received from brachytherapy for the last five years covering > 500 cases. Our results showed that with a proper radiation safety program in place, the dose to cath lab staff was negligible. It was concluded that radiation safety of personnel was easy to maintain during catheter-based coronary brachytherapy using Ir-192 seed sources.

Air Pollution, Radioactive↗

Physics of vascular brachytherapy.

Basic physics plays an important role in understanding the clinical utility of radioisotopes in brachytherapy. Vascular brachytherapy is a very unique application of localized radiation in that dose levels very close to the source are employed to treat tissues within the arterial wall. This article covers basic physics of radioactivity and differentiates between beta and gamma radiations. Physical parameters such as activity, half-life, exposure and absorbed dose have been explained. Finally, the dose distribution around a point source and a linear source is described. The principles of basic physics are likely to play an important role in shaping the emerging technology and its application in vascular brachytherapy.

Arteries↗

Physics and safety aspects of a coronary irradiation pilot study to inhibit restenosis using manually loaded 192Ir ribbons.

Radiation therapy has been successfully used in controlling some forms of benign tissue growth. A pilot study has been launched to evaluate the usefulness of localized radiation therapy in reducing restenosis after coronary angioplasty. In this randomized, double-blind study, patients with known restenosis received balloon angioplasty or additional stent implantation and were then randomized to receive either radiation or placebo treatment. Active sources consisted of 192Ir in the form of cylindrical seeds (0.3 x 0.05 cm). The seeds are embedded in a nylon ribbon. The nylon ribbon is passed through an indwelling coronary catheter. For this pilot trial, radioactive sources were exposed to blood elements and, therefore, required sterilization. A method of sterilization is described. A working team was developed to perform coronary radiation procedures at our institution. A description of the procedure is provided.

Angioplasty, Balloon, Coronary↗

Extended field irradiation for carcinoma of the uterine cervix with positive periaortic nodes.

Forty-three patients were treated with extended field irradiation for periaortic metastasis from carcinoma of the uterine cervix (FIGO stages IB-IV). Twelve patients (28%) remained continuously free of disease to the time of analysis or death from intercurrent disease, 20 (46%) had persistent cancer within the pelvis, 11 (26%) had persistent periaortic disease, and 23 (53%) developed distant metastasis. The actuarial 5-year survival rate was 32%. The results correlated well with the periaortic tumor burden at the time of irradiation. None of 19 patients (0%) with microscopic or small (less than 2 cm) periaortic disease had periaortic failures, compared to 29% (4/14) of those with moderate-sized (2-5 cm) disease and 70% (7/10) of those with massive (greater than 5 cm) periaortic metastasis. Similarly, the 5-year survival rates were 50% (6/12) with microscopic disease, 33% (2/6) with small gross disease, 23% (3/13) with moderate-sized disease, and 0% (0/10) with massive periaortic metastases. Only 10% (1/10) of patients whose tumor extended to the L1-2 level survived 5 years, compared with 31% (9/29) of those whose disease extended no higher than the L3-4 level. The periaortic failure rates correlated to some extent with the dose delivered through extended fields, although the difference was not statistically significant. Only 8% (1/13) of those who had undergone extraperitoneal lymphadenectomies developed small bowel complications, compared with 25% (7/29) of those who had had transperitoneal lymphadenectomies. The incidence of small bowel obstruction was 8% (1/13) following periaortic doses of 4000-4500 cGy, 10% (1/10) after 5000 cGy, and 32% (6/19) after approximately 5500 cGy. From this, we concluded that the subset of patients who would benefit most from extended field irradiation are those in whom the residual disease in the periaortic area measures less than 2 cm in size at the time of treatment, whose disease extends no higher than L3, and whose cancer within the pelvis has a reasonable chance of control with standard radiation therapy techniques.

Adult↗

Three-dimensional viewing of and dosimetric calculations in Au-198 implants of the prostate.

A three-dimensional system for dosimetric calculation of radiation from interstitial brachytherapeutic implants was developed and was compared with conventional dosimetry performed with a commercial two-dimensional system. Software programs written for this study enabled the authors to place radioactive sources in the correct reconstructed anatomic locations, compute the isodose distribution around these sources, and display the isodose curves in their correct relationship to anatomic structures. Eight radiation oncologists evaluated the usefulness of both systems. Verification studies in phantoms and in 20 patients with gold-198 implants in the prostate gland showed that the experimental system was very accurate in volume reconstruction, seed localization, isodose distribution, point-dose calculation, and computation of dose-volume histograms. Although the dose depictions in the two systems matched almost exactly, statistically significant differences existed in interpretation of the dosimetric data generated by both systems. For example, the oncologists consistently believed that the dose to the prostate was lower when the three-dimensional system was used (P less than or equal to .0001).

Brachytherapy↗

A comparison of the roles of surgery and radiation therapy in the management of craniopharyngiomas.

Fifty-two patients with craniopharyngioma were seen between January 1961 and July 1986. Of these, 40 were treated with surgery alone, 8 with surgery and postoperative radiotherapy, and 3 with radiotherapy alone. One patient received no treatment. For the group treated with surgery alone, 33% (13/40) had local tumor control, 42.5% (17/40) developed major complications, and 71% (25/35) survived 5 years. With surgery and postoperative radiotherapy, 100% (8/8) had local tumor control, 25% (2/8) developed major complications, and 100% (7/7) survived 5 years. Two of the three patients treated with radiotherapy alone had local tumor control and the third was salvaged with surgery. The "complete resection" rate for 32 patients treated with radical surgery was 63% (20/32). Tumor control was achieved in 50% (10/20) of the patients treated with "complete resection" without radiotherapy, in 15% (3/20) of the patients treated with "incomplete resection" without radiotherapy, and in 100% (8/8) of the patients treated with "incomplete resection" and postoperative radiotherapy. In this series, doses of 5000-5500 cGy were as effective in achieving control as 5500-6000 or 6000-7000 cGy.

Adolescent↗

Alopecia associated with unexpected leakage from electron cone.

Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeV electron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.

Alopecia↗

A simple method for reducing ovarian dose during megavoltage irradiation of the breast.

Breast cancer in its early stages can be effectively treated with conservative surgery and irradiation. In young women who wish to subsequently bear children, reduction of ovarian dose during irradiation could be of great emotional significance. We describe a simple, convenient, cost-effective method by which ovarian dose was reduced from 18 cGy to 8 cGy during tangential irradiation of the intact breast with 6 MV photons.

Adenocarcinoma↗

Megavoltage radiation field matching on uneven surface.

Large radiation fields adjacent to each other require proper field matching to avoid overdosage at their junction. Various methods of determining optimum field separation have been discussed in the literature. However, these methods consider a perfectly flat surface of incidence throughout the irradiated area. In reality, it is more common for the patient thickness to vary within large fields, thus creating an uneven surface of incidence. In this paper, we have discussed the approach to gap calculation for an uneven surface of incidence. Dose measurements were made at the junction of two fields for 60Co, and 4, 6, and 24 MV X ray beams to verify this approach. Beam profiles measured under uneven surfaces indicated that the 50 percent dose decrement line did not shift towards the central axis for frequently encountered variations in patient thickness. Thus, careful geometric considerations could provide an optimum field separation. Ignoring the surface inhomogeneity may lead to field overlap and overdose at the junction.

Humans↗

Effect of collimator setting on the output of rectangular fields from linear accelerators.

The output (cGy/mu) of a rectangular field from a linear accelerator is not always the same as that of its equivalent square field. We have summarized output variations with upper and lower collimator setting for 4, 6, and 24 MV X-rays. It is concluded that an error in output on the order of a few percent is introduced for elongated fields if lower set of collimator jaws is used for setting the longer dimension of the field, and computing the output using equivalent square method. It is recommended that specific guidelines be developed regarding rectangular field setting on high energy linacs.

Humans↗

Interstitial radiation in recurrent malignant gliomas.

Twelve patients with recurrent supratentorial gliomas were treated with implanted 125I seeds. The interval from initial surgery to interstitial radiation ranged from 3 months to 9 years. The techniques for brachytherapy included volume implantation by craniotomy in one, stereotactic implantation with low-activity seeds in 7 and high-activity seeds in 4 patients. The total dose received ranged from 5,500 to 27,000 cGy. CT scans performed sequentially on all patients showed progressive attenuation in areas previously enhancing, suggestive of tumor necrosis produced by the interstitial sources. The mean and median survival of these patients was 23 and 22 weeks, with the 4 most recent patients still alive.

Adult↗

Choice of radioisotope in stereotactic interstitial radiotherapy of small brain tumors.

In stereotactic interstitial radiotherapy, small radioactive sources are placed within the brain tumor to deliver locally high radiation doses. The choice of the radioisotope depends upon the dose distribution around the isotope, energy of the emitted radiation, relative biological effectiveness, and finally, the cost and availability of the isotope. We have analyzed 198gold, 125iodine and 192iridium in terms of these four factors. Our results have shown that 125I is superior to the other two isotopes due to its soft X-rays and dosimetric as well as radiobiological properties. Unfortunately, it is the most expensive of these radioisotopes, and can be difficult to obtain in specific activities.

Brachytherapy↗

Normal brain irradiation during stereotactic brain implants using radioactive iodine-125.

Stereotactic interstitial brain implants deliver locally high radiation doses to treat malignant gliomas. Dose to the surrounding normal brain from an 125I implant has been compared with the dose from an external irradiation technique. Results show that an implant offers a higher dose gradient around the tumor and hence a lower dose to the normal brain. Moreover, some irregular-shaped tumors, while ideal for a stereotactic implant, may be very difficult to treat with external beams without delivering a significant radiation dose to the normal brain. An implant seems to be dosimetrically superior to external irradiation for delivering large tumor doses.

Brachytherapy↗

The American Brachytherapy Society perspective on intravascular brachytherapy.

BACKGROUND: Recent clinical studies indicate that intravascular brachytherapy (IVB) can reduce the rate of restenosis substantially after angioplasty procedures. However, no clinical guidelines exist for optimal therapy. METHODS: The members of the IVB Subcommittee of the American Brachytherapy Society (ABS) identified the areas of consensus and controversies in IVB to issue the ABS perspective on IVB, based on analysis of published reports and the clinical experience of the members in brachytherapy. RESULTS: IVB is still experimental. The long-term efficacy, toxicity, the target tissue, and dose required for IVB are not established. The ABS recommends that IVB procedures must be performed, with careful attention to radiation-related issues, in the context of controlled multidisciplinary clinical trials with the approval of the institutional review board, the Nuclear Regulatory Commission, the Food and Drug Administration, and under an Investigational Device Exemption. The therapeutic radiologist, with a qualified radiation physicist, is responsible for dose prescription and delivery and needs to be present during the IVB procedure as part of this multidisciplinary team. The long-term outcome from these studies should be reviewed critically and published in peer-reviewed journals. The ABS endorsed the dosimetric guidelines of the American Association of Physicists in Medicine Task Group 60 (AAPM TG-60) report. The ABS recommends that dose specification be defined clearly; to allow comparisons between studies, the dose should be prescribed at 2 mm from the source for intracoronary brachytherapy and at an average luminal radius of +2 mm for peripheral vascular brachytherapy. The prescription doses at the above point is generally in the 12-18 Gy range. Comprehensive procedures for quality assurance, radiation protection, and emergencies should be in place before initiating an IVB program. Higher energy beta sources, lower energy gamma sources, dose-volume histograms, and correlation of three-dimensional reconstructions of delivered dose with patterns of failure are areas for further research. CONCLUSION: The ABS perspective on IVB is presented to assist the interventional team in developing protocols for the use of IVB in the prevention of restenosis. Long-term outcome data with a standardized reporting system are needed to establish the role of brachytherapy in preventing vascular restenosis. Endovascular brachytherapy is a new and evolving modality, and these recommendations are subject to modifications as new data become available.

Brachytherapy↗