PubMed Health⌕ Search

Biomedical subjects

S K Poole

Publications and source records attributed to S K Poole.

8 recordsLinked to original sources

An integrated process for measuring the physicochemical properties of drug candidates in a preclinical discovery environment.

Automated log P, pK(a), solubility, and chemical stability systems comprise an integrated process that provides early stage physicochemical property data to the discovery research organization. Capillary electrophoresis (CE) techniques are used to experimentally determine pK(a) and log P. Solubility is determined using a quasi-equilibrium approach employing sample quantitation by flow injection analysis with ultraviolet (UV) detection at 256 nm. Chemical stability is assessed by challenging compounds with pH 2, pH 7, pH 12, and 3% hydrogen peroxide solutions overnight, and comparing the chromatographic profiles of the stability challenged solutions to that of a freshly prepared control. Validation of the log P method using a set of drug-like compounds demonstrates that the method yields log P values within +/-0.5 units of literature values. The log P method is valid over the range -0.5-5.0, and the technique is compatible with acidic, neutral, and basic compounds. The pK(a) technique yields results within +/-0.2 units of corresponding values obtained by potentiometric titration over a pK(a) range of 2 to 12. Solubility is reported in a 3-60 microg/mL range, and the results are generally within 20% of values measured by equilibrium solubility techniques. The current level of automation supports the measurement of the physicochemical properties of 100 compounds per week. Physicochemical property data for approximately 2000 compounds have been generated to date.

Automation↗

Rapid method for estimating the octanol--water partition coefficient (log P ow) by microemulsion electrokinetic chromatography.

Several surfactant systems were evaluated based on their system constants determined by the solvation parameter model for the design of a surrogate chromatographic model for the rapid estimation of octanol-water partition coefficient (log Pow) by microemulsion electrokinetic chromatography. The system constant ratios responsible for the log Pow partition system are (nearly) the same as those for the microemulsion system containing sodium dodecyl sulfate (1.4% w/v), butan-1-ol (8% v/v) and heptane (1.2% v/v). Neutral and basic compounds are analyzed using a fused-silica capillary column with a 50 mM sodium phosphate-sodium borate (3:2) buffer at pH 10. Weakly acid compounds require the use of sulfonated silica capillary column and a 50 mM sodium phosphate buffer at pH 3. For 29 varied neutral and weakly basic compounds the average error between log Pow estimated using MEEKC and literature values was +/-0.12 over a log Pow range from 0.3 to 5.8.

Chromatography, Micellar Electrokinetic Capillary↗

Chromatographic models for the sorption of neutral organic compounds by soil from water and air.

The solvation parameter model is used to construct models for the estimation of the soil-water and soil-air distribution constants and to characterize the contribution of fundamental intermolecular interactions to the underlying sorption processes. Wet soil is shown to be quite cohesive and polar but relatively non-selective for dipole-type, lone-pair electron and hydrogen-bond interactions. Using a comparison of system constant ratios chromatographic systems employing reversed-phase liquid chromatography on polar bonded phases are shown to provide suitable models for estimating soil-water distribution constants. No suitable gas chromatographic models were found for the soil-air distribution constant but the requirements for such a system are indicated. Models are also provided for adsorption at the air-water interface. Estimation methods based on either the solvation parameter model or chromatographic model reproduce experimental distribution constants for a wide variety of compounds with a similar error (0.2-0.3 log units) to that expected in the experimental data.

Adsorption↗

Determination of kinetic and retention properties of cartridge and disk devices for solid-phase extraction.

The kinetic properties of cartridge and disk solid-phase extraction devices are determined by forced-flow liquid chromatography. Typical cartridges provide about 5-15 theoretical plates per cm of bed height and particle-loaded membranes provide about 4-9 theoretical plates for a 0.5-mm-thick membrane. It is shown that cartridge devices fail to provide their maximum trapping performance because of inadequate packing density and that the required packing density could be easily achieved in practice with particles of a standard size. The retention properties of common sorbents for extraction from water and air are characterized with the solvation parameter model. For predominantly aqueous solutions a favorable cavity term results in increased retention while polar interactions tend to reduce retention. Retention on porous polymer sorbents is more complicated because of their capacity to absorb significant amounts of the sample processing solvent resulting in solvent-dependent changes in retention properties. For trapping organic volatiles from air cavity formation and dispersion interactions are important, and in the case of Tenax its capacity for induction interactions is also significant.

Adsorption↗

Separation of pharmaceutically important estrogens by micellar electrokinetic chromatography.

Baseline separation of ten estrogens of the type found in conjugated estrogens tablets from pregnant mares' urine were separated by micellar electrokinetic chromatography with a 20 mM sodium borate-sodium phosphate buffer (pH 8) containing either 75 mM sodium cholate and 15 mM beta-cyclodextrin or 50 mM sodium dodecyl sulfate and 20 mM gamma-cyclodextrin. The system containing sodium cholate was used to identify estrogens in a pharmaceutical tablet formulation of conjugated estrogens and to determine the amounts and ratio of sodium equilin sulfate to sodium estrone sulfate to confirm tablet conformity with regulatory requirements. Baseline separation of the seven ethynyl steroids registered as oral contraceptives in the USA was obtained with the system 20 mM sodium borate-sodium phosphate buffer (pH 8) containing 50 mM sodium cholate and 10% (v/v) methanol. Factors that affect selectivity and reproducibility of the above separation systems are discussed.

Animals↗

Progress in densitometry for quantitation in planar chromatography.

The principal methods for obtaining quantitative information from separations performed by planar chromatographic techniques are reviewed. Recent advances in obtaining structural information for sample identification of separated components are also discussed. Reasonable expectations concerning future developments in densitometry are made.

Chemistry, Clinical↗

Preparation of environmental samples for the determination of polycyclic aromatic hydrocarbons by thin-layer chromatography.

An evaluation of extraction procedures, liquid-liquid distribution systems, Sep-Pak cartridges, liquid-solid chromatography using silica, alumina and chemically modified silica packings (acid-base treated ethylammonium nitrate and picric acid impregnated), macroreticular resins and gel permeation columns for the analysis of polycyclic aromatic hydrocarbons (CPAHs) in environmental samples by thin-layer chromatography is discussed. For particulate samples solvent extraction using a Soxhlet apparatus or ultrasonication was found to be preferable to sublimation and liquid-liquid distribution between hexane and dimethyl sulfoxide followed by silica gel column chromatography was the preferred method for sample clean-up. Using this procedure enabled six PAHs (anthracene, fluoranthene, benz[a]anthracene, perylene, pyrene, and coronene) to be determined quantitatively in urban air particulate, diesel engine exhaust particulate, laboratory ventilator dust, household dust, river water, and tea samples. The PAHs were identified by coincidence of retention between the sample and standards in the same chromatographic system and by adequate agreement with standards for their normalized emission response ratios. The two-point calibration method was used for quantitation. Good agreement for the concentration of PAHs in the air particulate and diesel particulate extracts with published data using gas chromatography-mass spectrometry and high-performance liquid chromatography was found.

Chromatography, Gel↗