PubMed Health⌕ Search

Biomedical subjects

S K Satija

Publications and source records attributed to S K Satija.

4 recordsLinked to original sources

Effect of density fluctuating supercritical carbon dioxide on polymer interfaces.

We investigated an effect of CO2 sorption on the compatibility of immiscible polystyrene (PS) and polybutadiene (PB) bilayers by using in situ neutron reflectivity. By labeling either polymer with deuterium, we found that the excess CO2 molecules were adsorbed to both top PS and bottom PB layers when the bilayers were exposed to CO2 at the narrow T and P regime near the critical point of pure CO2. Furthermore, we clarified that this excess sorption of CO2 molecules increased the interfacial width between the layers up to 100 angstroms even near room temperature, while the interfacial width without CO2 exposure has been reported to be at most 40 A even at the highest temperature (T congruent with 175 degrees C).

Journal Article↗

Early-stage compositional segregation in polymer-blend films.

The existence of a transient period during the surface enrichment of a binary polymer blend by one of its components has been suggested by previous theoretical and experimental studies as well as computer simulations. Taking advantage of the high depth resolution of neutron reflectivity and the slow dynamics of polymers near their glass transition, we investigate this early-stage surface compositional enrichment in a phase separating polymer blend for the first time. Two stages of surface enrichment layer growth are observed. A rapid local surface enrichment at the chain segmental level occurs first, followed by a slower growth of a diffuse layer having a scale on the order of the bulk correlation length and the radius of gyration of the surface enriching polymer chains.

Journal Article↗

Ligand accessibility as means to control cell response to bioactive bilayer membranes.

We report a new method to create a biofunctional surface in which the accessibility of a ligand is used as a means to influence the cell behavior. Supported bioactive bilayer membranes were created by Langmuir-Blodgett (LB) deposition of either a pure poly(ethylene glycol) (PEG) lipid, having PEG head groups of various lengths, or 50 mol % binary mixtures of a PEG lipid and a novel collagen-like peptide amphiphile on a hydrophobic surface. The peptide amphiphile contains a peptide synthetically lipidated by covalent linkage to hydrophobic dialkyl tails. The amphiphile head group lengths were determined using neutron reflectivity. Cell adhesion and spreading assays showed that the cell response to the membranes depends on the length difference between head groups of the membrane components. Cells adhere and spread on mixtures of the peptide amphiphile with the PEG lipids having PEG chains of 120 and 750 molecular weight (MW). In contrast, cells adhered but did not spread on the mixture containing the 2000 MW PEG. Cells did not adhere to any of the pure PEG lipid membranes or to the mixture containing the 5000 MW PEG. Selective masking of a ligand on a surface is one method of controlling the surface bioactivity.

Biocompatible Materials↗

Comparison of tethered star and linear poly(ethylene oxide) for control of biomaterials surface properties.

Four different poly(ethylene oxide) [PEO] molecules were compared as grafted polymer layers for biomaterials' substrates: two linear polymers and two star polymers. Conditions maximizing surface coverage for each molecule were employed with the aim of inhibiting protein adsorption and increasing the density of end groups. Neutron reflectivities of the grafted layers immersed in deuterium oxide (heavy water) were measured and used to calculate volume fraction profiles of the polymer as a function of distance from the surface. These density profiles were combined with protein adsorption data on the grafted layers to compare with recent theoretical and experimental studies of protein resistance by PEO at surfaces. We found that the grafting density is maximized by coupling the linear PEO from a K2SO4 salt buffer, which is a poor solvent for PEO. However, the grafting density of star PEO was maximized when no K2SO4 was used and the stars were dissolved near the overlap concentration. Concentration profiles obtained from the reflectivity data show that the hydrated polymers swell to approximately 10 times the dried layer thickness and exhibit a low density (maximum volume fractions < 0.4 PEO) throughout the layer. The PEO surfaces obtained with both the star and linear polymers resisted adsorption of cytochrome-c and albumin except for a small amount of cytochrome-c adsorption on the short, many-armed star polymer surface. A hypothesis of adsorption on the star polymer layer is presented and criteria for controlling receptor-mediated cell-substrate interactions by ligand-modified chain ends are discussed.

Adsorption↗