PubMed Health⌕ Search

Biomedical subjects

S K Yu

Publications and source records attributed to S K Yu.

At least 19 recordsLinked to original sources

Resistance to adefovir dipivoxil in lamivudine resistant chronic hepatitis B patients treated with adefovir dipivoxil.

BACKGROUND: Adefovir dipivoxil (ADV) is a potent nucleotide analogue against both the wild-type and lamivudine (LMV) resistant hepatitis B virus (HBV). The cumulative incidence of ADV resistant mutations in the nucleoside/-tide treatment naive chronic hepatitis B patient (CHB) at weeks 48, 96, and 144 was 0, 0.8-3%, and approximately 5.9%, respectively. AIMS: The aim of this study was to characterise the genotypic and phenotypic mutation profiles to ADV in 67 LMV resistant CHB patients who were treated with ADV. METHODS: Serum HBV DNA was quantified by real time polymerase chain reaction. The ADV mutant was detected using matrix assisted laser desorption/ionisation time of flight mass spectrometry based genotyping assays, termed restriction fragment mass polymorphism (RFMP). RESULTS: RFMP analysis revealed that a total of 11 amino acid substitutions developed in the rt domain of the HBV polymerase in nine patients. The cumulative incidence of genotypic ADV resistance at months 12 and 24 was 6.4% and 25.4%, respectively. The rtA181V, rtN236T, and rtA181T mutations were detected in five, four, and two of the 67 patients at treatment months 12-17, 3-19, and 7-20, respectively. Serial quantification of serum HBV DNA revealed that two patients with the rtA181V mutation, with or without the rtN236T mutation, and one patient with the rtA181T mutation displayed HBV DNA rebound. CONCLUSION: Emergence of the ADV mutation in LMV resistant patients who are treated with ADV appeared to present earlier and more frequently than was reported in previous studies on nucleoside/-tide treatment naive patients.

Adenine↗

Reduction of radiation dose to patients undergoing barium enema by dose audit.

Nowadays, new fluoroscopic machines are usually equipped with a dose-area product (DAP) meter for dose measurement. In our hospital, DAP meters have been used in the Diagnostic Radiology Department for dose audit since June 1997. Demographic patient data, name of radiologist, fluoroscopic duration and DAP readings of every case were recorded by radiographers. In early 1999, questionnaires were distributed to radiologists who had performed fluoroscopic examinations during the auditing period. 23 radiologists with varying years of experience completed the questionnaire and their practice was analysed. Since familiarization with the examination technique would affect radiologists' practice, these radiologists were divided into two groups for analysis. Radiologists with less than 3 years of experience were grouped together as junior radiologists, whilst others were grouped as senior radiologists. Results of the questionnaire indicated that radiologists generally found DAP meters useful for dose evaluation in the process of technique refinement. Radiologists aware of being under continuous surveillance of their practice showed significant reduction of doses (junior radiologists 25%, p<0.005; senior radiologists 36%, p<0.05) and fluoroscopic times (junior radiologists 36%, p<0.001; senior radiologists 18%, p<0.05) compared with radiologists who were unaware that they were under surveillance but with similar radiological experience. This effect is believed to be because of increased awareness of radiation dose through audit. In addition, this "audit effect" may also affect junior radiologists in decision-making regarding the number of radiographs (p<0.05), but no effect was found for senior radiologists (p>0.5).

Barium Sulfate↗

MAPD--an objective way to select mAs for paediatric brain CT.

CT is an advanced imaging modality, but the imaging parameters are normally selected subjectively. For standard head examinations, most of the parameters used are consistent amongst different centres, with the exception of large variations in the selection of the tube current-exposure time product (mAs). As a result, CT images may contain unacceptable levels of noise, or the patient may receive excessive radiation. In this study, the maximum anteroposterior diameter (MAPD) was shown to be a good criterion for mAs selection, and could be measured in a pilot view. 200 paediatric brain CT studies were randomly selected to determine the MAPD at the mid brain level. With knowledge of MAPD distribution, a phantom study was performed to determine the relationship between MAPD and the mAs required for consistent and acceptable image noise. It was found that the required mAs increased linearly with MAPD. Assuming the manufacturer's recommended value is "appropriate" for the average MAPD, the appropriate mAs value could be estimated. Using this method, appropriate mAs values were calculated retrospectively for a group of 240 randomly selected paediatric brain CT studies and compared with the actual mAs subjectively determined by the radiographer. Although their average values were similar, the difference between the calculated and actual values deviated markedly in some cases. When the actual mAs was smaller than the calculated value, higher image noise was observed. However, reduction of image noise was barely observed when the applied mAs was larger than the calculated value. Thus, this method is more objective and appropriate for determination of the mAs value for paediatric brain CT than the traditional subjective method.

Brain↗

Experimental lung transplantation using non-penetrating vascular clips for anastomosis of the pulmonary artery.

BACKGROUND: Reliable and rapid anastomosis is critical in lung transplantation. The purpose of this study is to show the appropriateness of sutureless anastomosis of the pulmonary artery using a nonpenetrating vascular clipping device. METHODS: The left lung was excised and the cranial lobe was transplanted autologously in 9 dogs. The anastomosis of the left main pulmonary artery (PA) (1 cm) was performed using a vascular clipping system. RESULTS: PA anastomosis was performed in 7 dogs in 8 to 13 minutes. The endovascular surface of the anastomotic site was smooth, and passage of silicone rubber through the anastomosis was good 14 or 28 days after surgery. Microscopic examination of the anastomotic sites showed excellent healing without evidence of intimal hyperplasia. CONCLUSIONS: The vascular clipping system facilitates anastomosis of the PA in lung transplant surgery.

Anastomosis, Surgical↗

Radiation dose reduction in paediatric cranial CT.

BACKGROUND: There is no consensus about the optimal milliamperage-second (mAs) settings for computed tomography (CT). Most operators follow the recommended settings of the manufacturers, but these may not be the most appropriate settings. OBJECTIVE: To determine whether a lower radiation dose technique could be used in CT of the paediatric brain without jeopardising the diagnostic accuracy of the images. MATERIALS AND METHODS: A randomised prospective trial. A group of 53 children underwent CT using manufacturer's default levels of 200 or 250 mAs; 47 underwent scanning at 125 or 150 mAs. Anatomical details and the confidence level in reaching a diagnosis were evaluated by two radiologists in a double-blinded manner using a 4-point scoring system. RESULTS: For both readers there was no statistically significant difference in the confidence level for reaching a diagnosis between the two groups. The 95 % confidence intervals and P values were -0.9-1.1 and 0.13 (reader 1) and -1.29-1.37 and 0.70 (reader 2), respectively. Reliability tests showed the results were consistent. CONCLUSIONS: The recommended level may not be the optimum setting. Dose reduction of 40 % is possible on our system in paediatric brain CT without affecting the diagnostic quality of the images.

Brain↗

Segmented attenuation correction using artificial neural networks in positron tomography.

The measured attenuation correction technique is widely used in cardiac positron tomographic studies. However, the success of this technique is limited because of insufficient counting statistics achievable in practical transmission scan times, and of the scattered radiation in transmission measurement which leads to an underestimation of the attenuation coefficients. In this work, a segmented attenuation correction technique has been developed that uses artificial neural networks. The technique has been validated in phantoms and verified in human studies. The results indicate that attenuation coefficients measured in the segmented transmission image are accurate and reproducible. Activity concentrations measured in the reconstructed emission image can also be recovered accurately using this new technique. The accuracy of the technique is subject independent and insensitive to scatter contamination in the transmission data. This technique has the potential of reducing the transmission scan time, and satisfactory results are obtained if the transmission data contain about 400,000 true counts per plane. It can predict accurately the value of any attenuation coefficient in the range from air to water in a transmission image with or without scatter correction.

Ammonia↗

Single-photon transmission measurements in positron tomography using 137Cs.

Transmission measurements are an essential step in the quantification of radioisotope distributions in vivo using positron tomographic techniques. The development of a new technique for measuring transmission data that relies on the detection of photons in 'singles' mode rather than 'coincidence' mode no longer restricts the choice of transmission sources to those that decay by positron emission. The motivation for using the 'singles' mode of operation is the substantial increase in count rate that can be achieved. This corresponds to a great increase in the statistical accuracy of the transmission data. We propose 137Cs as a suitable isotope for this purpose. 137Cs is more economical than 68Ge, the traditional source used for transmission measurements, in terms of longer half-life and lower financial cost. 137Cs can be used for transmission measurements without any recalibration of the tomograph, and the estimated spatial resolution is comparable to that obtained using annihilation photons. A simple extrapolation method is developed, which allows extrapolation of the attenuation coefficients measured at 662 keV to 511 keV. A dual-energy-window technique, whereby correction can be made on-the-fly during acquisition, is used for scatter correction. The measured linear attenuation coefficients agree with predicted values.

Cesium Radioisotopes↗

Shear stress-induced changes in platelet reactivity.

We have investigated the effects on platelet function of a physiologic shear stress. The aggregation to thrombin and collagen, the release reaction [(14C) serotonin] and the procoagulant activity of washed platelet suspensions were assayed on samples undergoing laminar oscillatory flow for 20 minutes at 37 degree C in polyethylene tubes, and on paired samples kept at rest. The pulse rate was established at 72 cycles per minute and the shear stress at the wall estimated at 26.2 dynes/cm2. The platelet suspensions were prepared at 37 degree C from blood samples of 15 healthy volunteers and 15 patients with the diagnosis of coronary artery disease proven by angiography. Our results show enhancement of platelet aggregation in samples undergoing oscillatory flow. Furthermore, platelets from coronary patients gained additional procoagulant activity. However, no change was encountered in the rate and speed of the release reaction. It is concluded that exposure to a high shear stress within an oscillatory flow system enhances platelet reactivity; this reaction may take part in the production of platelet and coagulation changes seen in the atherosclerotic patient and after strenuous physical exercise.

Adult↗

Potentiation by alpha and inhibition by beta-adrenergic stimulations of rat platelet aggregation. A comparative study with human and rabbit platelets.

Epinephrine, known to potentiate and elicit aggregation of human platelets, was shown to inhibit thrombin-induced aggregation of rat platelets, delaying the onset of aggregation from 2 to 12 times. Incubation of rat platelet suspensions with propranolol (1.25--30 micrometer), inactive by itself, totally prevented the inhibitory effect of epinephrine and also permitted a potentiation effect to show up. On the contrary, phentolamine (1.25--30 micrometer) potentiated the inhibitory effect of epinephrine on rat platelets and unmasked an inhibitory effect on human platelets. Finally, isoproterenol (0.25--9 micrometer) produced a marked inhibition of aggregation induced by thrombin, ADP and collagen in the three species studied, but most particularly in the rat. From these results, we conclude that stimulation of the platelet adrenergic receptors may either result in promotion (alpha-stimulation) or inhibition (beta-stimulation) of platelet aggregation. Furthermore, differences in the ratios or responses of alpha/beta receptors may account for species variations in the platelet aggregation response to catecholamine challenge.

Adenosine Diphosphate↗