Intramyocardial coronary flow characteristics in patients with hypertrophic cardiomyopathy: non-invasive assessment by transthoracic Doppler echocardiography.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to S Kaji.
Explore the source record for details and available documents.
A 59-year-old women was referred to our hospital due to severe dyspnea and shock status 12 days after intracranial hematoma evacuation for the hypertensive right putaminal hemorrhage. Transthoracic echocardiography revealed right ventricular dilatation and floating structures in the right atrium. Transesophageal echocardiography demonstrated a large, snake-like structure crossing her foramen ovale of the interatrial septum, and impending paradoxical embolism was diagnosed. She did not receive any anticoagulation and surgery due to recent cerebral hemorrhage. Follow-up TEE showed complete disappearance of the thrombus in the atrium two weeks after the onset. Phlebogram of deep vein demonstrated several thrombus in her leg. She underwent placement of inferior vena cava filter and was discharged from our hospital without any symptom of paradoxical embolism.
OBJECTIVES: The purpose of this study was to evaluate the value of transthoracic Doppler echocardiography (TTDE) for the noninvasive detection of total left anterior descending coronary artery (LAD) occlusion. BACKGROUND: Total coronary occlusion is associated with an adverse long-term prognosis, and mechanical revascularization may be required for the patient with total coronary occlusion. However, a noninvasive diagnosis of total coronary occlusion before coronary angiography (CAG) has been difficult, especially in patients without clinical signs. METHODS: We studied 103 consecutive patients who underwent CAG for the evaluation of coronary artery disease. The study group consisted of 16 patients with total LAD occlusion (group A) and 87 patients without total LAD occlusion (group B). Coronary flow velocity in the mid-portion of the LAD was recorded by TTDE. RESULTS: Adequate spectral Doppler recordings of diastolic flow in the LAD were obtained in 98 study patients (95%; 15 patients in group A and 83 patients in group B). In group A, retrograde LAD flow was obtained in 14 (93%) of 15 patients. The mean diastolic velocity of the retrograde flow was 21.0 +/- 6.1 cm/s. In group B, antegrade LAD flow was obtained in all 83 patients (100%). The mean diastolic velocity of the antegrade flow was 21.5 +/- 7.1 cm/s. Retrograde LAD flow by TTDE had a sensitivity of 93% and a specificity of 100% for the detection of total LAD occlusion. CONCLUSIONS: Retrograde flow in the LAD by TTDE is a highly sensitive and specific finding that can be used to noninvasively diagnose total LAD occlusion.
OBJECTIVES: The purpose of this study was to validate cardiac measurements derived from real-time cardiac magnetic resonance imaging (MRI) as compared with well-validated conventional cine MRI. BACKGROUND: Although cardiac MRI provides accurate assessment of left ventricular (LV) volume and mass, most techniques have been relatively slow and required electrocardiogram (ECG) gating over many heart beats. A newly developed real-time MRI system allows continuous real-time dynamic acquisition and display without cardiac gating or breath-holding. METHODS: Fourteen healthy volunteers and nine patients with heart failure underwent real-time and cine MRI in the standard short-axis orientation with a 1.5T MRI scanner. Nonbreath-holding cine MRI was performed with ECG gating and respiratory compensation. Left ventricular end-diastolic volume (LVEDV), left ventricular endsystolic volume (LVESV), ejection fraction (EF) and LV mass calculated from the images obtained by real-time MRI were compared to those obtained by cine MRI. RESULTS: The total study time including localization for real-time MRI was significantly shorter than cine MRI (8.6 +/- 2.3 vs. 24.7 +/- 3.5 min, p < 0.001). Both imaging techniques yielded good quality images allowing cardiac measurements. The measurements of LVEDV, LVESV, EF and LV mass obtained with real-time MRI showed close correlation with those obtained with cine MRI (LVEDV: r = 0.985, p < 0.001; LVESV: r = 0.994, p < 0.001; EF: r = 0.975, p < 0.001; LV mass: r = 0.977, p < 0.001). CONCLUSIONS: Real-time MRI provides accurate measurements of LV volume and mass in a time-efficient manner with respect to image acquisition.
We provide anatomic and functional evidence that nicotine induces angiogenesis. We also show that nicotine accelerates the growth of tumor and atheroma in association with increased neovascularization. Nicotine increased endothelial-cell growth and tube formation in vitro, and accelerated fibrovascular growth in vivo. In a mouse model of hind-limb ischemia, nicotine increased capillary and collateral growth, and enhanced tissue perfusion. In mouse models of lung cancer and atherosclerosis, we found that nicotine enhanced lesion growth in association with an increase in lesion vascularity. These effects of nicotine were mediated through nicotinic acetylcholine receptors at nicotine concentrations that are pathophysiologically relevant. The endothelial production of nitric oxide, prostacyclin and vascular endothelial growth factor might have a role in these effects.
Noninvasive imaging of the coronary arteries is one of the most important but challenging goals in medical imaging. Recent methods being developed for visualization of the coronary arteries include transthoracic and transesophageal echocardiography, electron-beam computed tomography, and magnetic resonance imaging. Transesophageal echocardiography is a feasible noninvasive technique for imaging the left main coronary artery and detecting hemodynamically significant luminal obstruction. Recent technological advances in transthoracic Doppler echocardiography provide measurement of coronary flow velocity in the distal portion of left anterior descending artery, which is useful for the assessment of coronary flow reserve, and therefore coronary stenosis and restenosis after coronary intervention in left anterior descending artery lesions. Electron-beam computed tomography is a cross-sectional imaging technique with high spatial and temporal resolution. It is possible for image acquisition to be triggered by the patient's electrocardiogram and this technique is well suited to cardiac imaging. Electron-beam computed tomography might be useful to detect or rule out high-grade coronary artery stenoses and occlusions, when image quality is adequate. Recent improvements and progress in coronary magnetic resonance angiography stem from the use of respiratory motion compensation and fast imaging methods. The most commonly used breath-hold method was developed with a fast segmented two-dimensional sequence on thin sections oriented to capture the coronary vessel inplane. Sensitivity and specificity of coronary magnetic resonance angiography in detecting significant coronary artery disease are 90% and 92% using this method.
Of 21,791 pregnant women screened in Tottori Prefecture, Japan, 127 (0.58%) were positive for anti-hepatitis C virus (HCV) antibody and 84 (0.39%) were positive for HCV RNA. Of 84 children followed up for at least 6 months, 7 (8%) were infected. All of them were born to 26 mothers with a high virus load (HVL; >/=2.5x106 RNA copies/mL [27%]), compared with 0 of 58 children born to non-HVL mothers (P<.001). Because all the infected children were vaginally delivered, the infection rate among 16 vaginally delivered children born to the HVL mothers was as high as 44%. The prevalence of anti-NS4 antibody in the mothers with an infectious HVL was significantly lower than that in the mothers with a noninfectious HVL (P=.048). Analysis of our results suggests that maternal HVL, vaginal delivery, and negative anti-NS4 antibody are significant risk factors for the mother-to-child transmission of HCV.
BACKGROUND: A residual stenosis and/or microvascular damage have been proposed as mechanisms of TIMI 2 flow for acute myocardial infarction. Coronary flow dynamics were assessed in patients with TIMI 2 flow to predict whether additional intervention would improve TIMI grade. METHODS AND RESULTS: In 35 patients who had a successfully recanalized anterior acute myocardial infarction using angioplasty or rescue stenting, coronary flow patterns were compared with corresponding TIMI grade and regional left ventricular wall motion (LVWM) 1 month after the intervention. After angioplasty, the time-averaged peak velocity (APV) was lower in patients with TIMI 2 flow (n=22) than in those with TIMI 3 flow (n=13; 7.9+/-3.9 versus 20.6+/-5.1 cm/s; P<0.001). Two different flow patterns were recorded in patients with TIMI 2 flow (versus TIMI 3, P<0.001); patients with type 1 TIMI 2 flow (n=15) had a reduced diastolic APV (8.3+/-4.8 versus 24.2+/-7.4 cm/s), prolonged diastolic deceleration time (1176+/-455 versus 728+/-205 ms), and a small diastolic/systolic APV ratio (1.3+/-0.6 versus 2.1+/-0.7); patients with type 2 TIMI 2 flow (n=7) had systolic flow reversal (systolic APV, -7.9+/-4.6 versus 11. 7+/-4.5 cm/s), a rapid diastolic deceleration time (221+/-84 versus 728+/-205 ms), and a negative diastolic/systolic APV ratio (-2.1+/-1. 4 versus 2.1+/-0.7). A significantly lower mean chord LVWM (-3.0+/-0. 2 versus -1.9+/-0.8; P<0.001) and a greater number of chords <-2SD (50+/-2 versus 28+/-18; P<0.001) were present in patients with type 2 versus type 1 TIMI 2 flow. Stenting increased TIMI 2 flow to TIMI 3 flow more in patients with type 1 than type 2 flow (67% versus 0%; P=0.003). Patients with TIMI 2 flow after stenting continued to demonstrate a type 2 pattern, and they had poor LVWM recovery. CONCLUSIONS: The differentiation between 2 types of TIMI 2 flow can predict the improvement of TIMI grade and LVWM recovery after additional stenting.
Compensatory enlargement occurred in 71% of lesions in patients with acute myocardial infarction and was more common in these patients than in patients with stable effort angina pectoris. These results suggest that compensatory enlargement may be associated with plaque rupture and subsequent acute myocardial infarction.
OBJECTIVES: The purpose of this study was to determine whether hyperinsulinemia during the oral glucose tolerance test is associated with increased neointimal tissue proliferation after coronary stent implantation in nondiabetic patients. BACKGROUND: Although hyperinsulinemia induces increased vascular smooth muscle cell proliferation in experimental models, it has not been determined whether hyperinsulinemia is associated with increased neointimal tissue proliferation after coronary stent implantation. METHODS: Serial (postintervention and six-month follow-up) intravascular ultrasound (IVUS) was used to study 67 lesions treated with Palmaz-Schatz stents in 55 nondiabetic patients. Cross-sectional images within stents were taken at every 1 mm, using an automatic pullback, and a neointimal index was calculated as the ratio between the averaged neointimal area and averaged stent area. All patients underwent a 75-g oral glucose tolerance test. Plasma glucose (PG) and immunoreactive insulin (IRI) levels were measured at baseline and 1 and 2 h after the glucose load. The sum of PGs (sigmaPG) and the sum of IRIs (sigmaIRI) were calculated. Body mass index (BMI), lipid levels, and glycosylated hemoglobin levels were measured. RESULTS: There were 27 patients with normal glucose tolerance, and 28 patients with impaired glucose tolerance (IGT). The neointimal index in patients with IGT was greater than that in patients with normal glucose tolerance (42.9 +/- 14% vs. 24.9 +/- 8.3%, respectively, p < 0.0001). Linear regression analysis showed that the neointimal index at follow-up correlated well with sigmaPG (p < 0.0001), fasting IRI (p < 0.0001), sigmaIRI (p < 0.0001), triglyceride level (p = 0.018), and BMI (p < 0.0001). Multiple regression analysis revealed that sigmaIRI (p = 0.0002) and sigmaPG (p = 0.0034) were the best predictors of the greater neointimal index at follow-up. CONCLUSIONS: Serial IVUS assessment shows that hyperinsulinemia during an oral glucose tolerance test is associated with increased neointimal tissue proliferation after coronary stent implantation in nondiabetic patients.
BACKGROUND: It has been reported that early surgery should be required for patients with type A aortic intramural hematoma (IMH) because it tends to develop classic aortic dissection or rupture. However, the anatomic features of type A IMH that develops dissection or rupture are unknown. The purpose of this study was to investigate the predictors of progression or regression of type A IMH by computed tomography (CT). METHODS AND RESULTS: Twenty-two consecutive patients with type A IMH were studied by serial CT images. Aortic diameter and aortic wall thickness of the ascending aorta were estimated in CT images at 3 levels on admission and at follow-up (mean 37 days). We defined patients who showed increased maximum aortic wall thickness in the follow-up CT (n=9) or died of rupture (n=1) as the progression group (n=10). The other 12 patients, who all showed decreased maximum wall thickness, were categorized as the regression group. In the progression group, the maximum aortic diameter in the initial CT was significantly greater than that in the regression group (55+/-6 vs 47+/-3 mm, P=0.001). A Cox regression analysis revealed that the maximum aortic diameter was the strongest predictor for progression of type A IMH. We considered the optimal cutoff value to be 50 mm for the maximum aortic diameter to predict progression (positive predictive value 83%, negative predictive value 100%). CONCLUSIONS: Maximum aortic diameter estimated by the initial CT images is predictive for progression of type A IMH.
BACKGROUND: In the era of primary percutaneous transluminal coronary angioplasty (PTCA), it is important to judge whether myocardium within acute ischemic injury is viable. This study sought to investigate parameters derived from the coronary blood flow velocity spectrum immediately after primary PTCA in patients with acute myocardial infarction and to elucidate the clinical value of coronary blood flow measurement in predicting myocardial viability. METHODS AND RESULTS: Using a Doppler guidewire, we measured coronary blood flow velocity after successful completion of primary PTCA in 23 consecutive patients with acute anterior myocardial infarction. Regional wall motion was analyzed to estimate anterior wall motion score index (A-WMSI) by echocardiography before PTCA and 1 month after the onset of symptoms. Average systolic peak velocity (ASV) and deceleration time of diastolic flow velocity (DDT) significantly correlated to 1-month A-WMSI (r=-0.54, P=0.007 and r=-0.62, P=0.002, respectively), and optimal cutoff values to predict viable myocardium (defined as 1-month A-WMSI </=2.0) were 6.5 cm/s for ASV and 600 ms for DDT (sensitivity=0.79, specificity=0.89 and sensitivity=0.86, specificity=0.89, respectively). ASV and DDT also correlated weakly to the change in A-WMSI (r=0.46, P=0.03 and r=0.49, P=0.02, respectively). CONCLUSIONS: Low ASV and rapid DDT of coronary blood flow spectrum immediately after primary PTCA reflects a greater degree of microvascular damage in the risk area. Analysis of coronary blood flow spectrum immediately after primary PTCA by use of a Doppler guidewire is useful in predicting recovery of regional left ventricular function.
Four major hemodynamic subsets from cardiac index (CI) and mean pulmonary artery (PA) wedge pressure with a PA catheter usually reflect clinical status and prognosis of patients with acute myocardial infarction (AMI). Recently, a new color Doppler technique has been developed for automated cardiac output measurements (ACOM). Color Doppler echocardiography also provides noninvasive estimation of PA wedge pressure from pulmonary venous (PV) flow analysis. This study evaluates the value of ACOM and PV flow analysis by color Doppler echocardiography for the assessment of hemodynamic subsets in patients with AMI. We performed ACOM and PV flow analysis by color Doppler echocardiography in 55 patients with AMI who underwent hemodynamic assessment with a PA catheter. From both noninvasive and invasive methods, we classified hemodynamic subsets as follows: subset I: normal hemodynamics (CI >2.2 L/min/m2, PA wedge pressure < or =18 mm Hg); subset II: pulmonary congestion (CI >2.2 L/min/m2, PA wedge pressure >18 mm Hg); subset III: peripheral hypoperfusion (CI < or =2.2 L/min/m2, PA wedge pressure < or =18 mm Hg); and subset IV: pulmonary congestion and peripheral hypoperfusion (CI < or =2.2 L/min/m2, PA wedge pressure >18 mm Hg). Doppler assessment of hemodynamic subsets was possible in 50 of 55 patients (91%). CI from ACOM correlated well with that from the thermodilution method (r = 0.94) with close agreement. There was a good correlation between the systolic fraction (systolic velocity-time integral expressed as a fraction of the sum of systolic and diastolic velocity-time integrals) of PV flow and PA wedge pressure measured from cardiac catheterization (r = -0.83). When we determined the value of 45% in the systolic fraction as the cut-off point in predicting >18 mm Hg in PA wedge pressure, there was 90% (45 of 50 patients) agreement between noninvasive and invasive hemodynamic subsets. Thus, ACOM and PV flow analysis by color Doppler echocardiography is useful in the noninvasive assessment of hemodynamic subsets in patients with AMI.
OBJECTIVES: This study investigates the correlation between deceleration time of diastolic pulmonary venous flow (PV-DT) and of early filling mitral flow (LV-DT), and pulmonary capillary wedge pressure (PCWP) in patients with acute myocardial infarction (AMI). BACKGROUND: An earlier study suggests that Doppler-derived LV-DT provides an accurate means of estimating PCWP in postinfarction patients with left ventricular systolic dysfunction. Furthermore, recent studies have suggested that PCWP correlates better with PV-DT than with LV-DT. However, the value of PV-DT and LV-DT for assessment of PCWP in patients with AMI has not been evaluated. METHODS: In 141 consecutive patients with AMI, we measured PV-DT and LV-DT by Doppler echocardiography, and compared these variables with PCWP measured using a Swan-Ganz catheter. RESULTS: There was a weak negative correlation between the LV-DT and PCWP (r = -0.54). Although the sensitivity of < or =130 ms in LV-DT in predicting > or =18 mm Hg in PCWP was high (86%), its specificity was low (59%). On the other hand, a very close negative correlation was found between PV-DT and PCWP (r = -0.89). The sensitivity and specificity of < or =160 ms in PV-DT in predicting > or =18 mm Hg in PCWP were 97% and 96%, respectively. CONCLUSIONS: In patients with AMI, Doppler-derived PV-DT showed a stronger correlation with PCWP than LV-DT.
Recognition of the involved lesions is extremely important in mitral valve repair for infective endocarditis. Transesophageal echocardiography (TEE) is more sensitive for the detection of lesions than transthoracic echocardiography, but localization of the lesions is sometimes difficult by TEE. Three-dimensional (3D) TEE provides images of the mitral valve similar to the view from the left atrium. This study evaluated the value of 3D echocardiography for the diagnosis of involved lesions in 12 patients who underwent surgery for mitral regurgitation due to infective endocarditis. The location of the lesion in the mitral valve was classified as the medial, central and lateral portions of the anterior leaflet, and the medial, middle and lateral scallops of the posterior leaflet, respectively. In all patients, the involved sites were confirmed at operation. The sensitivities of 3D TEE for detecting the lesions at the medial, central and lateral portions of the anterior leaflet, and the medial, middle and lateral scallops of the posterior leaflet were 100%, 78% and 67%, and 100%, 100% and 100%, respectively. The specificities were 90%, 100% and 78%, and 100%, 100% and 100%, respectively. The lesions diagnosed by 3D TEE coincided with lesions confirmed at operation in 23 (92%) of 25 lesions. 3D TEE is useful for the assessment of the involved lesion of the mitral valve in patients with infective endocarditis.
The color Doppler echocardiographic technique has been developed for automated cardiac flow measurement (ACM). This study evaluated the effect of imaging parameters on stroke volume measurement. Cardiac output derived from the ACM method was compared with that obtained from pulsed wave Doppler in 36 patients (26 men and 10 women, mean age 54 +/- 8 years) in whom clear two-dimensional and color Doppler images of the left ventricular outflow tract were obtained. The effects of frame rate, color gain and moving target indicator (MTI) filter on cardiac output were evaluated in 13 patients (8 men and 5 women, mean age 49 +/- 6 years). Using ACM at a frame rate of 30 Hz, optimal color gain setting and high-frequency MTI filter (cutoff frequency: 915 Hz), there was an excellent correlation in cardiac output between the ACM and pulsed wave Doppler methods (stroke volume: r = 0.91, SEE = 0.32 l/min). Using ACM at a frame rate of 30, 22 and 15 Hz, the differences in stroke volume were 4.4%, 5.2% and 8.6%, respectively. When color gain was reduced, left ventricular stroke volume reduction was 12.1% (-2 dB), 18.9% (-4 dB). In contrast, there was no significant change in stroke volume measurement when color gain was increased. There was a significant decrease in stroke volume using the low-frequency MTI filter [cutoff frequency: 467 Hz (-35.6%)] and medium-frequency MTI filter [cutoff frequency: 703 Hz (-13.4%)]. Color Doppler imaging parameters are extremely important for automated assessment of cardiac output.
OBJECTIVES: This study sought to assess the flow dynamics of internal mammary artery grafts (IMAGs) in no-flow situations by use of a Doppler guide wire. BACKGROUND: Functionally no-flow and anatomically patent IMAGs have been reported by angiography in patients with a patent recipient coronary artery. METHODS: The study included 12 patients with an IMAG to the left anterior descending coronary artery (LAD) in whom no-flow patency of the graft was suspected angiographically. Thirteen patients with a normally functioning IMAG whose LAD was occluded in the proximal portion and was supplied only from the graft served as control patients. Phasic flow velocities were recorded in the distal portion of the graft and the recipient LAD using a 0.014-in., 15-MHz Doppler guide wire at rest and during hyperemia (0.14-mg/kg body weight per min intravenous adenosine infusion). RESULTS: There were no significant differences in systolic (15+/-3 vs. 19+/-6 cm/s, p = NS), diastolic (35+/-11 vs. 37+/-7 cm/s, p = NS) and time-averaged peak velocities at rest (20+/-5 vs. 21+/-5 cm/s, p = NS), during hyperemia (51+/-12 vs. 54+/-8 cm/s, p = NS) and in coronary flow velocity reserve (2.8+/-0.9 vs. 2.7+/-0.3, NS) in the native LAD in patients with a no-flow patent graft versus control patients. Within the graft, to and fro signals with systolic reversal and diastolic anterograde flow were seen in the no-flow patent grafts, although anterograde flow signals were recorded in systole and diastole in control patients. Systolic (-28+/-19 vs. 22+/-9 cm/s, p < 0.01), diastolic (18+/-17 vs. 44+/-14 cm/s, p < 0.01) and time-averaged (-2+/-6 vs. 26+/-9 cm/s, p < 0.01) peak velocities at rest were significantly smaller in the no-flow patent grafts than in control grafts. During hyperemia, anterograde flow became predominant, with a reduction in retrograde systolic flow signal and an increase in diastolic flow velocity and time-averaged peak velocity in the no-flow patent grafts, and no-flow situations disappeared temporarily. CONCLUSIONS: Functionally no-flow situations of IMAGs manifesting to and fro signals with systolic flow reversal and diastolic antegrade low flow velocity are temporary conditions in certain hemodynamic circumstances, and these grafts function as conduits during hyperemic states.
OBJECTIVES: The purpose of this study was to evaluate whether transthoracic Doppler echocardiography (TTDE) can reliably measure coronary flow velocity (CFV) and coronary flow velocity reserve (CFVR) in the left anterior descending coronary artery (LAD) in the clinical setting. BACKGROUND: Coronary flow velocity measurement has provided useful clinical and physiologic information. Advancement in TTDE provides noninvasive measurement of CFV and CFVR in the distal LAD. METHODS: In 23 patients, CFV in the distal LAD was measured by TTDE (5 or 3.5 MHz) under the guidance of color Doppler flow mapping at the time of Doppler guide wire (DGW) examination. Coronary flow velocity in the distal LAD were measured at baseline and hyperemic conditions (intravenous administration of adenosine 0.14 mg/kg/min) by both TTDE and DGW techniques. Coronary flow velocity reserve was defined as the ratio of peak hyperemic to basal averaged peak velocity in the distal LAD. RESULTS: Clear envelopes of basal and hyperemic CFV in the distal LAD were obtained in 18 (78%) of 23 study patients by TTDE. There were excellent correlations between TTDE and DGW methods for the measurements of CFV (averaged peak velocity: r=0.97, y=0.94x + 0.40; averaged diastolic peak velocity: r=0.97, y=0.94x + 0.69; systolic peak velocities: r=0.97, y=0.91x + 0.87; diastolic peak velocity: r=0.98, y=0.95x + 1.10). Coronary flow velocity reserve from TTDE correlated highly with those from DGW examinations (r=0.94, y=0.95x + 0.21). CONCLUSIONS: Noninvasive measurement of CFV and CFVR in the distal LAD using TTDE accurately reflects invasive measurement of CFV and CFVR by DGW method.