PubMed Health⌕ Search

Biomedical subjects

S Karacagil

Publications and source records attributed to S Karacagil.

At least 19 recordsLinked to original sources

Renal artery stenosis evaluated with 3D-Gd-magnetic resonance angiography using transstenotic pressure gradient as the standard of reference. A multireader study.

PURPOSE: To evaluate 3D-Gd-magnetic resonance angiography (MRA) in detecting hemodynamically significant renal artery stenosis (RAS). MATERIAL AND METHODS: Thirty patients evaluated for atherosclerotic RAS by MRA and digital subtraction angiography (DSA) were retrospectively included. Standard of reference for hemodynamically significant RAS was a transstenotic gradient of 15 mmHg. DSA visualized 60 main renal arteries and 9 accessory arteries. Pressure gradient measurement (PGM) was available from 61 arteries. Three radiologists evaluated all examinations independently in a blinded fashion. RESULTS: RAS was present in 26 arteries. On MRA, each reader identified 4 of 9 accessory renal arteries, a detection rate of 44%. The three readers correctly classified 22/25/22 of the 26 vessels with a significant gradient as > or =60% RAS and 31/25/32 of the 35 with no significant gradient as < 60% RAS on MRA. Interobserver agreement was substantial. MRA image quality was adequate for RAS evaluations in all patients. ROC curves indicated that MRA is an adequate method for evaluating RAS. When screening for RAS, a 50% diameter reduction cut-off is better than 60%. RAS with 40-80% diameter reductions accounted for 65% of discrepancies. CONCLUSION: MRA is an adequate method for evaluating RAS limited mainly by poor detection rate for accessory renal arteries.

Aged↗

The importance of adjusting for differences in proximal and distal contrast bolus arrival times in contrast-enhanced iliac artery magnetic resonance angiography.

We tested the hypothesis that differences in proximal and distal contrast bolus arrival times may result in insufficient vascular signal in the distal part of the aortoiliofemoral territory with routinely used timing techniques. The difference in arrival time of the contrast medium bolus between the aorta and the common femoral arteries was measured in 14 patients undergoing magnetic resonance angiography of the aortoiliac arteries. A dual-station test bolus technique adjusting for this difference was evaluated. The variation coefficient of the signal intensity in six defined locations and signal intensities (SI) normalised to fat were calculated. Comparisons were made with findings in 13 patients examined with a fluoroscopically triggered timing technique (BolusTrak, Philips Medical Systems, Best, The Netherlands). The difference in bolus arrival time between proximal and distal vessels was 0-7 s. In 3 of 14 patients it was 5.6-7 s. There was a tendency towards a lower mean variation coefficient in the dual-station group ( p=0.10). With both techniques, significantly lower SIs were measured in the femoral arteries compared with SIs in the superior part of the abdominal aorta. In two cases in the BolusTrak group, a distal vessel could not be delineated but was shown to be patent on a delayed scan. Differences in contrast medium arrival time along the vessel may be large enough to preclude visualisation of distal vessels unless there is compensation. A dual-station test bolus technique taking this into account was found to be feasible.

Adult↗

Duplex scanning as the sole preoperative imaging method for infrainguinal arterial surgery.

OBJECTIVE: to evaluate preoperative duplex as the sole investigation prior to lower limb reconstruction. Design retrospective analysis. MATERIALS AND METHODS: between January 1995 and December 1999, 157 of 329 surgical interventions for chronic infrainguinal arterial or aneurysmal disease were performed without preoperative angiography. RESULTS: in patients undergoing femoral artery endarterectomy, the extent of the stenosis and the status of the distal deep femoral artery were correctly diagnosed with duplex scanning in all but one patient. Duplex scan findings in patients undergoing infrainguinal bypass procedures were in agreement with the findings obtained from on-table angiography in regard to the selection of optimal outflow anastomotic sites in 123 (98%). Duplex scanning correctly evaluated the status of runoff in 113 (90%). There were no significant differences in 30-day occlusion rate and patency at 12 months between reconstructions performed with and without preoperative angiography. CONCLUSION: in patients with conclusive duplex scan findings there is no need to perform angiography prior to lower limb reconstruction.

Adolescent↗

Distal percutaneous transluminal angioplasty through infrainguinal bypass grafts.

AIM: to evaluate the results of transluminal angioplasty (PTA) performed through infrainguinal bypass grafts for stenotic or occlusive lesions at the distal anastomosis and/or in the runoff arteries. DESIGN: retrospective clinical study. MATERIAL AND METHODS: forty-one patients underwent 57 procedures at the distal anastomosis (n=13), in the runoff arteries (n=32) or at both locations (n=12) at a median of 9.6 months (range, 2-76 months) after infrainguinal bypass grafting. Nineteen procedures were on the popliteal artery, the rest on the crural arteries. Eleven procedures related to occlusions less than 5 cm in length. RESULTS: technical success was achieved in 91%. Primary and primary assisted graft patency rates at 3 years were 32% and 53%, respectively. There were no significant differences in patency rates with regard to the graft material, the type of lesion, the level of PTA, the status of runoff and the use of thrombolysis before PTA. No patients underwent amputation as a direct consequence of failed PTA or graft occlusion. One patient underwent acute surgical intervention due to graft occlusion at the time of attempted PTA. CONCLUSION: the results of PTA at the distal anastomosis and/or in the runoff arteries in limbs with infrainguinal bypass seemed to be inferior to the results of surgical revisions reported in literature. However, as failed PTA did not jeopardise vein-patch angioplasty or jump grafting, it is a reasonable alternative to surgical intervention in selected cases.

Aged↗

Duplex scan findings in patients with spontaneous cervical artery dissections.

AIM: to report duplex scan findings in patients with spontaneous internal carotid artery (ICA) or vertebral artery (VA) dissection. MATERIAL AND METHODS: the records of 24 patients (13 males and 11 females, median age 48 years [range 25-68 years]) with spontaneous extracranial ICA dissection (n=20) or VA dissection (n=4), identified between January 1995 and December 1999, were retrospectively analysed. RESULTS: four different abnormal flow patterns were observed in patients with ICA dissection: (a) absence of flow (15%), (b) staccato flow (50%), (c) reduced flow velocity (25%) and, (d) stenotic flow (10%). B-mode ultrasound showed a homogenous echolucent lesion in eight patients and a double lumen in two. Staccato flow along the entire ICA was observed in only four patients without verified dissection during the study period. In the four patients with VA dissection, duplex scanning demonstrated staccato flow in three and reversed low-amplitude pulsatile flow in one. CONCLUSION: duplex scanning is an important noninvasive diagnostic modality in patients with cervical artery dissection. Staccato flow along the extracranial ICA strongly indicates the presence of spontaneous ICA dissection.

Adult↗

Endovascular approach to treating secondary arterioureteral fistula.

Two patients with the rare entity of arterio-ureteral fistula are presented. Both highlight the predisposing factors of radiation, major surgery in the region, history of vascular surgery and presence of double-J-stent. Both patients presented with the clinical sign of intermittent gross hematuria. Both patients were successfully treated by endovascular intervention using graft covered stent.

Aged↗

High-resolution carotid artery MRA. Comparison with fast dynamic acquistion and duplex ultrasound scanning.

PURPOSE: To determine whether the diagnostic accuracy of contrast-enhanced MR angiography (CE-MRA) of the carotid arteries is improved by using a slow-injection, high-resolution technique. MATERIAL AND METHODS: In 22 patients suspected to have internal carotid artery (ICA) stenosis at duplex ultrasound scanning (DUS), CE-MRA was performed both with a fast, dynamic (8 s/phase) and with a slower, high-resolution technique (scan time 2:20 min). RESULTS: There was conformity between the CE-MRA techniques regarding the degree of stenosis in 34/40 extracranial ICAs. In 3/6 discrepant cases, short occlusions were seen with the fast dynamic technique, whereas both the high-resolution CE-MRA technique and DUS showed patent vessels. There was an overall tendency toward higher stenosis grading with the dynamic technique. Overlying veins could be removed on a workstation in all high-resolution examinations. CONCLUSION: The high-resolution carotid CE-MRA technique proposed herein seems to improve the diagnostic accuracy, at least for differentiation between high-grade stenoses and occlusions.

Carotid Artery, Internal↗

Selection of patients with infrainguinal arterial occlusive disease for percutaneous transluminal angioplasty with duplex scanning.

AIM: To evaluate the role of duplex scanning in the selection of patients with infrainguinal arterial occlusive disease for percutaneous transluminal angioplasty (PTA). MATERIAL AND METHODS: From January 1995 through May 2000, 702 patients (952 limbs), with chronic lower extremity ischemia due to infrainguinal atherosclerotic disease diagnosed by duplex scanning, were retrospectively studied. Diagnostic angiography (130 limbs) or infrainguinal PTA (108 limbs) was performed in 238 limbs. Two investigators retrospectively analyzed the duplex examinations and angiographies in a blinded manner and used similar criteria for the interpretation of lesions suitable or not suitable for PTA. RESULTS: The superficial femoral, popliteal and crural artery lesions were correctly selected for PTA in 85%, 66% and 32%, respectively. The accuracy, sensitivity, specificity, negative predictive value and positive predictive value of duplex scanning to appropriately categorize femoropopliteal lesions as suitable or unsuitable for PTA were 89%, 83%, 92%, 94% and 78%, respectively. The accuracy of duplex scanning for predicting the performance of infrainguinal PTA was 83%. CONCLUSION: Duplex scanning has an important impact on the selection of treatment modalities in limbs with infrainguinal arterial occlusive disease. Femoropopliteal lesions can be reliably selected to PTA according to duplex scan findings.

Aged↗

Biomarkers of free radical injury during spinal cord ischemia.

Plasma and urinary levels of 8-iso-PGF(2alpha) and 15-keto-dihydro-PGF(2alpha) were analysed at baseline and during the ischemia-reperfusion period in experimental spinal cord ischemia. A significant and immediate increase of 8-iso-PGF(2alpha) in plasma at the start and up to 60 min, and in the urine at 90-150 min following ischemia indicate an association of oxidative injury. The inflammatory response indicator 15-keto-dihydro-PGF(2alpha) in plasma increased significantly at the start and up to 60 min after ischemia. No such increase was seen in animals with no spinal cord ischemia. Thus, free radical mediated and cyclooxygenase catalysed products of arachidonic acid are increased during spinal cord ischemia as a consequence of oxidative injury and inflammation.

Animals↗

The importance of Doppler angle of insonation on differentiation between 50-69% and 70-99% carotid artery stenosis.

AIM: to investigate the importance of Doppler angle differentiating between 50-69% and >/=70% internal carotid artery (ICA) stenosis. MATERIAL AND METHODS: fifty-one patients with a previous diagnosis of 50-69% ICA stenosis (n =53) were re-evaluated by duplex scanning. Spectral Doppler velocity waveforms were obtained from common carotid (CCA), ICA and external (ECA) carotid arteries with the same Doppler angle of insonation as used at the initial duplex scanning, followed by repeated measurements with a fixed 60 degrees angle of insonation. RESULTS: the peak systolic velocity (PSV) in the ICA was 181+/-55 cm/s (mean+/-SD) at the second duplex scanning when the same angle of insonation (mean 46 degrees +/-9) was used as during the initial investigation. When the examination was done with a 60 degrees angle of insonation, PSV ICA was 261+/-96 cm/s (mean+/-SD). In fifteen arteries the estimated degree of ICA stenosis changed from 50-69% to 70-99% due to the application of a fixed Doppler angle of insonation at 60 degrees. CONCLUSION: the Doppler angle of insonation has a significant effect on spectral Doppler velocity measurements. It is crucial that duplex criteria are standardised with a fixed angle of insonation and that this angle is consistently used during velocity estimations.

Carotid Artery, Internal↗

Floating nonocclusive thrombus in the common femoral artery detected by duplex scanning after removal of the arterial catheter: a case report.

A 5-year-old girl is reported in whom duplex scanning showed a nonocclusive thrombus in the common femoral artery that was removed successfully by surgical intervention. Noninvasive examination with duplex scanning in patients with signs of acute arterial insufficiency during or after removal of femoral artery catheter is recommended.

Catheterization↗

Monitoring of intrathecal oxygen tension during experimental aortic occlusion predicts ultrastructural changes in the spinal cord.

OBJECTIVE: To study the correlation between intrathecal PO2 and ultrastructural changes in the spinal cord during thoracic aortic occlusion in pigs. MATERIAL AND METHODS: In 18 pigs, online intrathecal oxygenation was monitored by a multiparameter Paratrend catheter (Biomedical Sensors, High Wycombe, United Kingdom) during 60 minutes' clamping of the proximal and distal descending thoracic aorta. The animals were randomly divided into 2 groups (A and B) depending on the level of distal aortic clamping. Distal aortic perfusion was restored through an aorto-iliac shunt, which also maintained low thoracic segmental perfusion of the spinal cord in group B. Perfusion-fixation technique was used before harvesting the spinal cord specimens, which later were evaluated with light and electron microscopy by an independent observer. Intrathecal parameters were interpreted as normal if PO2 was more than 0.8 kPa and PCO2 was less than 12 kPa, as intermediate ischemia if PO2 was 0.8 or less or PCO (2) was more than 12 kPa, and as absolute ischemia if PO2 was 0.8 or less and PCO2 was more than 12 kPa. RESULTS: Among 6 animals with ultrastructural changes of absolute spinal cord ischemia-reperfusion injury, 5 also had absolute ischemia according to variables derived by the Paratrend catheter. The 2 methods were in agreement in 3 of 5 animals with intermediate ischemia-reperfusion changes and in 5 of 6 animals with normal findings. The accuracy of cerebrospinal fluid PO2 and PCO2 to predict electron microscopy-verified intermediate or absolute ischemia-reperfusion injury was 94%. CONCLUSIONS: Monitoring of intrathecal PO2 after clamping of the descending aorta correlated with ultrastructural changes in the spinal cord in this pig model.

Animals↗

Aspects of the spinal cord circulation as assessed by intrathecal oxygen tension monitoring during various arterial interruptions in the pig.

OBJECTIVE: We sought to study the effect of various modes of interruption of the spinal cord blood supply on intrathecal oxygenation. METHODS: In 24 pigs intrathecal PO (2), PCO (2), and pH were continuously monitored with a multiparameter catheter (Paratrend 7, Biomedical Sensors; Diametrics Medical, Inc, St Paul, Minn) during and after aortic crossclamping or selective interruption of segmental arteries and proximal collateral circulation. RESULTS: Proximal aortic clamping (n = 6) produced complete ischemia, whereas a second clamp close to the celiac trunk (n = 4) partly protected against spinal cord ischemia. This is explained by prevention of the steal phenomenon in the excluded part of the aorta. Adding clamps to the subclavian arteries (n = 6) created complete spinal ischemia as the collateral circulation was interrupted. In another group (n = 4) all segmental arteries below T5 were occluded with no reaction in the intrathecal variables. Additional selective clamping of supreme intercostal arteries (n = 4) showed the relative importance of the subclavian and vertebral collateral pathways. CONCLUSIONS: Continuous intrathecal PO (2) was monitored during various modes of interruption of the spinal cord blood supply. This provided insight into the ischemia mechanisms and relative importance of the segmental contribution and proximal collateral pathways of the spinal cord circulation in pigs. A short literature review is given, and aspects of comparative anatomy are discussed.

Animals↗

Percutaneous transluminal angioplasty of the femoropopliteal arteries in limbs with chronic critical lower limb ischemia.

PURPOSE: The aim of the study was to evaluate the results of percutaneous transluminal angioplasty (PTA) of femoropopliteal arteries in patients with subcritical or critical lower limb ischemia. MATERIALS AND METHODS: Ninety-two patients underwent 121 PTA procedures, 68 were of the superficial femoral artery (SFA), 13 of the popliteal and 40 of both arteries. Fifty-seven procedures were performed for treatment of occlusions. Eighty-four patients (94 procedures) were monitored with duplex scanning. RESULTS: Technical success rate was 88%. Primary success rates at 12 and 60 months in the whole series were 40% and 27%, respectively. The primary success rate in limbs with SFA occlusion of longer than 5 cm was only 12% after 5 years compared with 32% if the occlusion was </= 5 cm in length (P <.01). The primary success rate at 60 months was 53% in limbs with single SFA stenosis and 42% in those with multiple stenoses (P = NS). Limb salvage rate for combined endovascular and vascular interventions was 86% at 5 years. The overall survival rate was 51% at 5 years. CONCLUSION: The results of femoropopliteal PTA performed for treatment of subcritical or critical lower limb ischemia seemed to be inferior to the results of infrainguinal bypass grafting reported in literature. However, because the PTA procedure does not preclude the performance of bypass grafting, it might be an alternative to surgical intervention in limbs with stenotic femoropopliteal lesions. PTA might also be considered in patients with high surgical risk and limited life expectancy, having short occlusive lesions (< 5 cm).

Adult↗

Increased FiO2 improves intrathecal oxygenation during thoracic aortic cross-clamping in pigs.

OBJECTIVES: To investigate the effect of 100% oxygen ventilation on cerebrospinal fluid (CSF) oxygenation in 11 pigs during thoracic aortic cross-clamping. DESIGN: An aorto-aortic shunt was used for control of central hemodynamics and study of hypoperfusion by exsanguination. CSF PO2, PCO2 and pH were continuously monitored before and during clamping. The changes in hemodynamic parameters and intrathecal gas tensions in response to variations in proximal mean aortic pressure and fraction of inspired oxygen (FiO2) were recorded. RESULTS: Baseline CSF PO2 decreased from 4.8 +/- 1.9 to 2.6 +/- 2.2 kPa following aortic occlusion. Increasing FiO2 to 1.0 resulted in a significant increase in CSF PO2 to 4.1 +/- 3.0 with a return to 2.7 +/- 2.1 kPa after reducing FiO2 to 0.4 again. The same variations in FiO2 did not induce any significant changes in CSF PO2 during hypotension. CONCLUSION: Increased FiO2 during experimental thoracic aortic cross-clamping with stable proximal arterial pressure helps to maintain CSF PO2, whereas severe hypotension could not be compensated for by hyperoxemia.

Animals↗

Influence of low proximal aortic pressure on spinal cord oxygenation in experimental thoracic aortic occlusion.

BACKGROUND: To evaluate the effect of low proximal aortic pressure on cerebrospinal fluid (CSF) oxygenation in an experimental thoracic occlusion model. METHODS: In nine pigs, continuous intrathecal pO(2), pCO(2) and pH monitoring was used during double descending thoracic aortic clamping following insertion of an aorto-aortic shunt. In five pigs, the shunt was connected to a citrated bag adjusted at approximately 40-45 cm above the heart for partial exsanguination in order to decrease mean proximal aortic pressure (MPAP) to below 50 mmHg. In four animals, sodium nitroprusside infusion was used for this purpose. RESULTS: Intrathecal pO(2) demonstrated a significant decrease from 4.9+/-2.1 to 2.9+/-2.4 kPa after 10 minutes of aortic cross-clamping. Lowering proximal aortic pressure caused a further significant decrease to 1.2+/-1.7 kPa (p<0.05). In seven pigs (5 in the exsanguination and 2 in the vasodilator group), restoration of mean proximal aortic pressure to 94.0+/-27.7 caused a recovery of CSF pO(2) from 1.2+/-1.9 to 2.8+/-3.0 (p<0.05). CONCLUSIONS: The results of this study demonstrate that MPAP which provides spinal cord perfusion through subclavian-vertebral arteries are crucial for maintenance of spinal cord oxygenation during thoracic aortic occlusion in this pig model.

Animals↗

Surgical strategy for large or malignant endocrine pancreatic tumors.

Endocrine pancreatic tumors (EPTs) are rare but have a remarkably better prognosis than adenocarcinoma of the pancreas. Patients with EPTs benefit from surgical and medical therapy, which may alleviate symptoms due to hormonal excess and increase survival. Patients with large or malignant EPTs with infiltrative disease may suffer from local complications, including gastrointestinal bleeding and obstruction and involvement of the superior mesenteric (SMV) and portal (PV) veins. Among 31 patients with operable and large or malignant EPTs, 7 had hormone-producing syndromes (insulin, glucagon), and 24 had clinically nonfunctioning EPTs. Surgery in these patients included vascular reconstruction of the SMV/PV (n = 4), resection of infiltrated adjacent organs (n = 5; stomach, transverse colon), or resection of concomitant liver metastases (n = 3). Four patients with conspicuously large insulinomas, and three with glucagonoma were successfully operated on with alleviation of hormonal symptoms. Among the 24 nonfunctioning EPTs, 5 patients had been explored earlier and their tumors judged inoperable due to locally invasive disease or misdiagnosis as pancreatic adenocarcinoma. The operations were performed with no mortality and low morbidity. We conclude that large and malignant EPTs with limited spread of disease may benefit from a combination of medical and surgical therapy.