PubMed Health⌕ Search

Biomedical subjects

S Kawahito

Publications and source records attributed to S Kawahito.

At least 19 recordsLinked to original sources

Effects of acute normovolemic hemodilution on ventriculoarterial coupling in dogs.

BACKGROUND: Acute normovolemic hemodilution (ANH) causes a decrease in systemic vascular resistance. Similar to vasodilating drugs, ANH might modify ventriculoarterial coupling. Left ventricular elastance (Ees), effective arterial elastance (Ea), stroke work (SW), and pressure volume area (PVA) were used as indicators to examine the effects of ANH on this coupling. METHODS: After institutional approval eight dogs were anesthetized with isoflurane and subjected to measurements including aortic pressure, left ventricular (LV) pressure, and LV volume. Left ventricular volume was measured with a conductance catheter. Ees was determined as the slope of the end-systolic pressure-volume relationship. Ea was determined as the ratio of LV end-systolic pressure to stroke volume. Ventriculoarterial coupling was evaluated as the ratio of Ees to Ea. Mechanical efficiency, another criterion for ventriculoarterial coupling, was calculated as the ratio of SW to PVA. Data are expressed as mean+/-SD, and P<0.05 was considered significant. RESULTS: Normovolemic exchange of 50 ml kg-1 of blood for 6% hydroxyethyl starch (ANH50) reduced hemoglobin concentration from 12.8+/-3.0 g dl-1 to 6.4+/-1.3 g dl-1. Acute normovolemic hemodilution 50 did not change Ees significantly although it significantly decreased Ea. Left ventricular elastance/Ea did not change after ANH (1.0+/-0.4 at baseline and 1.2+/-0.5 at ANH50). Acute normovolemic hemodilution 50 significantly increased SW and PVA, preventing SW/PVA from changing significantly after ANH (0.57+/-0.10 at baseline and 0.62+/-0.14 at ANH50). CONCLUSION: Before ANH, ventriculoarterial coupling was so matched as to maximize SW at the expense of the work efficiency. This relation was preserved at ANH50.

Algorithms↗

Dynamic QRS-complex and ST-segment monitoring by continuous vectorcardiography during carotid endarterectomy.

BACKGROUND: Many authors report a high incidence of cardiac events during carotid endarterectomy. The aim of the present study was to evaluate the usefulness of dynamic continuous on-line vectorcardiography for monitoring the occurrence of myocardial ischaemia during carotid endarterectomy. METHODS: We studied 21 patients undergoing carotid endarterectomy. Patients underwent general anaesthesia with isoflurane or sevoflurane. The vectorcardiogram was monitored continuously during carotid endarterectomy. Electrodes were placed according to the previously described lead system and connected to a computerized system for on-line vectorcardiography. Two trend variables were recorded: the QRS vector difference, which reflects changes in the shape of the QRS complex; and the ST vector magnitude, which represents deflection of the ST segment from the isoelectric level. The ST segment deflection was measured 60 ms after termination of the QRS complex. RESULTS: Vectorcardiography was successfully recorded in all 21 patients. Three patients showed intraoperative vectorcardiogram abnormalities. In one of these three patients, both ST vector magnitude and QRS vector difference increased after induction of anaesthesia and ST vector magnitude returned to baseline after administration of nitroglycerin. In the other two patients, both ST vector magnitude and QRS vector difference gradually increased after cross-clamping of the internal carotid artery and ST vector magnitude returned to baseline after unclamping. QRS vector difference remained elevated for several hours in all three patients. CONCLUSIONS: Monitoring ST vector magnitude and QRS vector difference by vectorcardiography may be useful for identifying myocardial ischaemia during carotid endarterectomy.

Aged↗

Development of a new hollow fiber silicone membrane oxygenator: in vitro study.

An experimental silicone hollow fiber membrane oxygenator for long-term extracorporeal membrane oxygenation (ECMO) was developed in our laboratory using an ultrathin silicone hollow fiber. However, the marginal gas transfer performances and a high-pressure drop in some cases were demonstrated in the initial models. In order to improve performance the following features were incorporated in the most recent oxygenator model: increasing the fiber length and total surface area, decreasing the packing density, and modifying the flow distributor. The aim of this study was to evaluate the gas transfer performances and biocompatibility of this newly improved model with in vitro experiments. According to the established method in our laboratory, in vitro studies were performed using fresh bovine blood. Gas transfer performance tests were performed at a blood flow rate of 0.5 to 6 L/min and a V/Q ratio (V = gas flow rate, Q = blood flow rate) of 2 and 3. Hemolysis tests were performed at a blood flow rate of 1 and 5 L/min. Blood pressure drop was also measured. At a blood flow rate of 1 L/min and V/Q = 3, the O2 and CO2 gas transfer rates were 72.45 +/- 1.24 and 39.87 +/- 2.92 ml/min, respectively. At a blood flow rate of 2 L/min and V/Q = 3, the O2 and CO2 gas transfer rates were 128.83 +/- 1.09 and 47.49 +/- 5.11 ml/min. Clearly, these data were superior to those obtained with previous models. As for the pressure drop and hemolytic performance, remarkable improvements were also demonstrated. These data indicate that this newly improved oxygenator is superior to the previous model and may be clinically acceptable for long-term ECMO application.

Animals↗

Gas transfer performance of a hollow fiber silicone membrane oxygenator: ex vivo study.

Based on the results of in vitro studies of many experimental models, a silicone hollow fiber membrane oxygenator for pediatric cardiopulmonary bypass (CPB) and extracorporeal membrane oxygenation (ECMO) was developed using an ultrathin silicone hollow fiber with a 300 microm outer diameter and a wall thickness of 50 microm. In this study, we evaluated the gas transfer performance of this oxygenator simulating pediatric CPB and ECMO conditions. Two ex vivo studies in a pediatric CPB condition for 6 h and 5 ex vivo studies in an ECMO condition for 1 week were performed with venoarterial bypass using healthy calves. At a blood flow rate of 2 L/min and V/Q = 4 (V = gas flow rate, Q = blood flow rate) (pediatric CPB condition), the O2 and CO2 gas transfer rates were maintained at 97.44 +/- 8.88 (mean +/- SD) and 43.59 +/- 15.75 ml/min/m2, respectively. At a blood flow rate of 1 L/min and V/Q = 4 (ECMO condition), the O2 and CO2 gas transfer rates were maintained at 56.15 +/- 8.49 and 42.47 +/- 9.22 ml/min/m2, respectively. These data suggest that this preclinical silicone membrane hollow fiber oxygenator may be acceptable for both pediatric CPB and long-term ECMO use.

Animals↗

Hemodynamic exercise response in calves with an implantable biventricular centrifugal blood pump.

An implantable biventricular assist device (BVAD) has been developed at Baylor College of Medicine using 2 centrifugal blood pumps. The aim of this study was to investigate the exercise-reflex response during nonpulsatile biventricular assistance and to evaluate to which degree the autoregulation of the system would accommodate the changed hemodynamic situation during physical exercise. The Baylor Gyro PI 710 BVAD has been implanted into 2 calves (strain half-Dexter) in a biventricular bypass fashion with native heart remaining. Allowing a 10 day convalescence, 2 animals were subjected to incremental exercise tests. The speed of the treadmill was increased at zero slope from 0.7 mph to 1.5 mph with increments of 0.2 mph every 3 min. During the exercise the pump flows were maintained at a fixed rate (6.93 +/- 0.01 L/min for the left ventricular assist device and 5.36 +/- 1.44 L/min for the right ventricular assist device). Hemodynamic parameters and pump performance were recorded continuously. The cardiac output (CO) and heart rate (HR) increased significantly during the exercise. CO increased from 11.1 +/- 0.3 to 13.1 +/- 0.4 L/min, and HR increased from 99 +/- 7.1 to 114 +/- 2.8 bpm, respectively. Mean aortic pressure, central venous pressure, and left arterial pressure did not change significantly. Also, no change was observed for the left and right pump flows. This totally implantable BVAD showed excellent long-term performance without any mechanical problems. It is feasible to operate without impairment under physical activity. However, the natural heart dominated the hemodynamic response during exercise under BVAD support. The left and the right pump flows did not increase spontaneously with exercise. We therefore conclude that a servo CO control system is necessary to regulate pump flows even during moderate exercise.

Animals↗

Development of the Baylor Gyro permanently implantable centrifugal blood pump as a biventricular assist device.

The Baylor Gyro permanently implantable centrifugal blood pump (Gyro PI pump) has been under development since 1995 at Baylor College of Medicine. Excellent results were achieved as a left ventricular assist device (LVAD) with survival up to 284 days. Based on these results, we are now focusing on the development of a biventricular assist device (BVAD) system, which requires 2 pumps to be implanted simultaneously in the preperitoneal space. Our hypothesis was that the Gyro PI pump would be an appropriate device for an implantable BVAD system. The Gyro PI 700 pump is fabricated from titanium alloy and has a 25 ml priming volume, pump weight of 204 g, height of 45 mm, and pump diameter of 65 mm. This pump can provide 5 L/min against 100 mm Hg at 2,000 rpm. In this study, 6 half-Dexter healthy calves have been used as the experimental model. The right pump was applied between the infundibular of the right ventricle and the main pulmonary artery. The left pump was applied between the apex of the left ventricle and the thoracic descending aorta. As for anticoagulation, heparin was administered at the first postoperative week and then converted to warfarin sodium from the second week after surgery. Both pump flow rates were controlled maintaining a pulmonary arterial flow of less than 160 ml/kg/min for the sake of avoidance of pulmonary congestion. Blood sampling was done to assess visceral organ function, and the data regarding pump performance were collected. After encountering the endpoint, which the study could not keep for any reasons, necropsy and histopathological examinations were performed. The first 2 cases were terminated within 1 week. Deterioration of the pump flow due to suction phenomenon was recognized in both cases. To avoid the suction phenomenon, a flexible conduit attached on the inlet conduit was designed and implanted. After using the flexible inflow conduit, the required power and the rotational speed were reduced. Furthermore, the suction phenomenon was not observed except for 1 case. There was no deterioration regarding visceral organ function, and pulmonary function was maintained within normal range except for 1 case. Even though the experimental animal survived up to 45 days with the flexible inflow conduit, an increase in power consumption due to thrombus formation behind the impeller became a problem. Lower rotational speed, which was probably produced by the effectiveness of the flexible inflow conduit, was speculated to be one of the reasons. And the minimum range of rotational speed was 1,950 rpm in these 6 BVAD cases and the previous 3 cases of LVAD. In conclusion, 6 cases of BVAD implantation were performed as in vivo animal studies and were observed up to 45 days. The flexible inflow conduit was applied in 4 of 6 cases, and it was effective in avoiding a suction phenomenon. The proper rotational speed of the Gyro PI 700 pump was detected from the viewpoint of antithrombogenicity, which is more than 1,950 rpm.

Animals↗

Pulmonary arterial pressure can be estimated by transesophageal pulsed doppler echocardiography.

We examined whether pulmonary arterial pressure can be estimated on the basis of pulmonary arterial flow velocity determined via intraoperative pulsed Doppler transesophageal echocardiography (TEE) in 20 patients undergoing cardiac surgery. Standard pulmonary artery measurements were taken as well. Measurements were taken before sternotomy, after pericardiotomy, after cardiopulmonary bypass, and after sternum closure. The variables obtained by TEE included preejection period (PEP), acceleration time (AT), right ventricular ejection time (RVET), and R-R interval (RR). Five ratios were calculated as indices of pulmonary arterial pressure--PEP/AT, PEP/RVET, AT/RVET, PEP/ square root of RR, and AT/ square root of RR--and were compared with pulmonary artery catheterization findings, i.e., systolic pulmonary arterial pressure (sPAP), log sPAP, mean PAP (mPAP), and log mPAP. Before sternotomy, PEP/AT, PEP/ square root of RR, and AT/ square root of RR showed significant correlation with all pulmonary artery catheterization values. AT/RVET showed correlation with all pulmonary artery values except log mPAP. PEP/AT showed the closest correlation with sPAP (r = 0.771) and log sPAP (r = 0.789). PEP/AT also showed close correlation with mPAP (r = 0.764) and log mPAP (r = 0.777). Significant agreement between sPAP and mPAP values calculated from a regression equation and values measured via pulmonary artery catheter was observed by plotting the differences against the mean values of the two measurements. We therefore conclude that noninvasive estimation of pulmonary arterial pressure is feasible via intraoperative TEE when sternotomy is not involved.

Adult↗

Bronchospasm induced by cardiopulmonary bypass.

Severe bronchospasm during cardiopulmonary bypass (CPB) is an unusual event. A 16-year-old girl with pulmonary stenosis who underwent reconstruction of the right ventricle outflow tract experienced severe bronchospasm following CPB. Just after the initiation of the partial CPB, high inspiratory airway pressure was suddenly recognized. The lung had become too stiff for the anesthetic circuit bag to be squeezed by hand. Tracheobronchial obstruction was ruled out by investigation with a fiberoptic bronchoscope. A presumptive diagnosis of severe bronchospasm was made, and aggressive bronchodilator therapy was instituted. The attack was successfully treated with aggressive bronchodilator therapy. Although the exact causes for bronchospasm in our case are not clear, CPB factors, such as the release of complements and allergic reactions might have induced the attack under relatively light anesthetic state.

Adolescent↗

Transesophageal echocardiographic assessment of pulmonary arterial and venous flow during high-frequency jet ventilation.

STUDY OBJECTIVE: To evaluate high-frequency jet ventilation (HFJV) effects on pulmonary arterial and venous flow compared to those of intermittent positive-pressure ventilation (IPPV) by using pulsed Doppler transesophageal echocardiography. DESIGN: Prospective clinical study. SETTING: University-affiliated hospital operating room. PATIENTS: 13 ASA physical status I and II patients undergoing lower abdominal or lower extremity surgery. INTERVENTIONS: PATIENTS had total IV anesthesia with propofol and fentanyl. After anesthesia induction, a transesophageal echocardiography probe was inserted into the esophagus. IPPV (TV, 8-10 mL/kg; respiratory rate, 10-12 cycles/min; I/E ratio, 1:2; FIO(2), 1.0) and HFJV (driving pressure, 0.5-0.6 kgf/cm(2); frequency,3 Hz; I/E ratio, 1:1; FIO(2), 1.0) were performed under hemodynamically stable conditions. MEASUREMENTS: Pulmonary-arterial-flow velocity, pulmonary-venous-flow velocity, left ventricular short-axis view, and airway-pressure curve were recorded simultaneously. Parameters measured were: hemodynamic variables, arterial blood gases, inspiratory airway pressure; [from pulmonary-arterial-flow velocity] pre-ejection period (PEP), acceleration time (AT), right ventricular ejection time (RVET), and their ratios (PEP/AT, AT/RVET); [from pulmonary-venous-flow velocity] time-velocity integral of the first systolic wave (S1), second systolic wave (S2), and diastolic wave (D), and systolic fraction (integral S1 + S2/S1+ S2 + D); [from M-mode] left-ventricular-end systolic volume, left-ventricular-end diastolic volume (LVEDV), stroke volume, cardiac output, and ejection fraction, using Teichholz's method. MAIN RESULTS: Peak inspiratory airway pressure during HFJV was significantly lower than that during IPPV. HFJV significantly decreased PEP/AT, correlating positively with pulmonary arterial pressure, and significantly increased AT and AT/RVET, correlating negatively with pulmonary arterial pressure. Systolic fraction, correlating negatively with left atrial pressure, increased significantly during HFJV, as did LVEDV, stroke volume, cardiac output, and ejection fraction. CONCLUSIONS: Our results suggest that, in comparison to IPPV, HFJV significantly decreases pulmonary arterial pressure and left atrial pressure, resulting in significant increases in cardiac output and ejection fraction in healthy anesthetized adults.

Abdomen↗

Nitric oxide does not play a major role in the regulation of systemic hemodynamic responses to acute normovolemic hemodilution.

BACKGROUND: The mechanisms of cardiovascular changes following acute normovolemic hemodilution (ANH) have not been fully elucidated. We tested the hypothesis that inhibition of nitric oxide synthesis attenuates ANH-induced cardiovascular responses. METHODS: We observed the effects of N(omega)-nitro-L-arginine methyl ester (L-NAME) pretreatment on ANH-induced cardiovascular responses and compared these effects with those elicited by phenylephrine (PHE). Twenty dogs anesthetized with isoflurane were divided into two groups: one group was pretreated with L-NAME and the other with PHE. Both groups were normovolemically hemodiluted using 6% hydroxyethyl starch to reduce the hemoglobin concentration to approximately 50% of the pretreatment value. RESULTS: Pretreatment with either L-NAME or PHE caused a significant increase in mean aortic blood pressure (MAP) and systemic vascular resistance (SVR) with a significant decrease in cardiac output (CO) and stroke volume (SV). However, no remarkable differences in these variables were seen between groups. In both groups ANH produced increases in heart rate, CO, SV, and maximal left ventricular dP/dt with a significant decrease in SVR. No significant differences in these variables were apparent after ANH except that MAP was decreased in the PHE group but not in the L-NAME group. CONCLUSION: Our results suggest that nitric oxide does not play a major role in mediation or modulation of the systemic vascular responses to ANH.

Animals↗

Analysis of the arterial blood pressure waveform using Fast Fourier Transform technique during left ventricular nonpulsatile assistance: in vitro study.

The arterial blood pressure waveform is variable during left ventricular assistance. The aim of this study is to examine the correlation between the left ventricular assist device (LVAD) condition and the arterial blood pressure waveform in a fixed cardiac output condition using a mock circuit. This mock circulation loop was composed of an aortic compliance chamber, a left atrial compliance chamber, a pneumatic pulsatile pump as a native heart, and a rotary blood pump representing the LVAD with left atrial drainage. The Fast Fourier Transform technique was utilized to analyze the arterial blood pressure waveform and calculate the pulsatility index (PI) and the pulse power index (PPI). The PI and PPI decreased with the increase of the LVAD rotational speed, exponentially. There was a significant negative correlation between the PI, PPI, and the LVAD rotational speed, flow rate, and assist ratio. The best correlation was observed between the PPI and the assist ratio (r = 0.986). From this viewpoint, an ideal LVAD condition may be estimated from the pulsatility change of the arterial blood pressure waveform.

Blood Pressure↗

Right ventricular assist system feedback flow control parameter for a rotary blood pump.

At least 25-30% of patients with a permanent implantable left ventricular assist device (LVAD) experience right ventricular failure; therefore, an implantable biventricular assist system (BiVAS) with small centrifugal pumps is being developed. Many institutions are focusing and developing a control system for a left ventricular assist system (LVAS) with rotary blood pumps. These authors feel that the right ventricular assist system (RVAS) with rotary blood pumps should be developed simultaneously. A literature search indicated no recent reports on the effect of hemodynamics and exercise with this type of nonpulsatile implantable RVAS. In this study, a calf with an implantable right ventricular assist system (RVAS) was subjected to 30 min of exercise on a treadmill at 1.5 mph, resulting in excellent hemodynamics. The input voltage remained unchanged. Hemodynamic recordings were taken every 5 min throughout the testing period, and blood gas analysis was done every 10 min. Oxygen uptake (VO2), oxygen delivery (DO2), and oxygen extraction (O2ER) were calculated and analyzed. Two different pump flows were investigated: Group 1 low assist (<3.5 L/min) and Group 2 high assist (>3.5 L/min). In both groups, the RVAS flow rates were unchanged while the pulmonary artery (PA) flow increased during exercise; also, the heart rate and right atrial pressure (RAP) increased during exercise. There were no significant differences in the 2 groups. The PA flow correlates to the heart rate during exercise. In all of the tests, the VO2 and DO2 increased during exercise. Regarding VO2, no changes were observed during the different flow conditions; however, the DO2 of Group 2 was higher than that of Group 1. Because the implantable RVAS did not have pump flow changes during the test conditions, it was necessary to incorporate a flow control system for the implantable RVAS. During exercise with an implantable RVAS rotary blood pump, incorporating the heart rate and VO2 as feedback parameters is feasible for controlling the flow rate.

Animals↗

Development of the NEDO implantable ventricular assist device with Gyro centrifugal pump.

The Gyro centrifugal pump, PI (permanently implantable) series, is being developed as a totally implantable artificial heart. Our final goal is to establish a "functional TAH," a totally implantable biventricular assist system (BiVAS) with centrifugal pumps. A plastic prototype pump, Gyro PI 601, was evaluated through in vitro and in vivo studies as a single ventricular assist device (VAD). Based upon these results, the pump head material was converted to a titanium alloy, and the actuator was modified. These titanium Gyro pumps, PI 700 series, also were subjected to in vitro and in vivo studies. The Gyro PI 601 and PI 700 series have the same inner dimensions and characteristics, such as the eccentric inlet port, double pivot bearing system, secondary vane, and magnet coupling system; however, the material of the PI 700 is different from the PI 601. The Gyro PI series is driven by the Vienna DC brushless motor actuator. The inlet cannula of the right ventricular assist system (RVAS) specially made for this system consists of 2 parts: a hat-shaped silicone tip biolized with gelatin and an angled wire reinforced tube made of polyvinylchloride. The pump-actuator package was implanted into 8 calves in the preperitoneal space, bypassing from the left ventricle apex to the descending aorta for the left ventricular assist system (LVAS) and bypassing the right ventricle to the main pulmonary artery for the RVAS. According to the PI 601 feasibility protocol, 2 LVAS cases were terminated after 2 weeks, and 1 LVAS case and 1 RVAS were terminated after 1 month. The PI 700 series was implanted into 4 cases: 3 LVAS cases survived for a long term, 2 of them over 200 days (72-283 days), and 1 RVAS case survived for 1 month and was terminated according to the protocol for a short-term antithrombogenic screening and system feasibility study. Regarding power consumption, the plastic pump cases demonstrated from 6.2 to 12.1 W as LVAS and 7.3 W as RVAS, the titanium pump cases showed from 10.4 to 14.2 W as LVAS and 15.8 W as RVAS. All cases exhibited low hemolysis. The renal function and the liver function were maintained normally in all cases throughout these experimental periods. In the 2 RVAS cases, pulmonary function was normally maintained. No calves demonstrated thromboembolic signs or symptoms throughout the experiments except Case 1 with the plastic pump. However, in the plastic pump cases, bilateral renal infarction was suspected in 2 cases during necropsy whereas no abnormal findings were revealed in the titanium pump cases. There were also no blood clots inside the PI 700 series. As for the 601, the explanted pumps demonstrated slight thrombus formations at the top and bottom pivots except in 1 case. The Gyro PI series, especially the PI 700 series, demonstrated superior performance, biocompatibility, antithrombogenicity and low hemolysis. Also, the durability of the actuator was demonstrated. Based on these results, this titanium centrifugal pump is suitable as an implantable LVAS and RVAS. It is likely that the Gyro PI series is a feasible component of the BiVAS functional TAH.

Animals↗

Gyro pump wear and deformation analysis in vivo study: creep deformation.

The Gyro pump has a double pivot bearing system to support its impeller. In this study, the integrity of the bearing system was examined after ex vivo studies. The pumps were implanted into calves and evaluated for different periods as a paracorporeal left ventricular assist device (LVAD). One pump was subjected to a test of 30 days, 1 for 15 days, 4 for 14 days, 1 for 10 days, 1 for 7 days, 2 for 4 days, and 4 for 2 days. One additional pump was subjected to percutaneous cardiopulmonary support (PCPS) condition for 6 days (total pressure head 500 mm Hg with a pump flow rate of 3 L/min). The anticoagulation treatment consisted of a continuous administration of heparin to maintain an achieved clotting time (ACT) of 200-250 s during the LVAD study and 250-300 s during the PCPS study. After the experiment, the pumps were disassembled, and the wear and deformation of male and female bearings were analyzed. There were no dimensional changes on male bearings but there were on female bearings. Wear and deformation of the female bearings were calculated as follows: wear and deformation = (depth of female before pumping) - (depth after pumping). Thirteen assembled Gyro pumps were disassembled to measure the depth of the female bearings before pumping. There was no statistical relationship between the wear and deformation and the motor speed x driving period. From these results, the deformation was not due to wear but to the creep or elastic deformation. This study suggested that the double pivot bearing system of the Gyro pump is highly durable.

Animals↗

Antithrombogenicity evaluation of a centrifugal blood pump.

The Gyro C1E3 pump was developed not only for cardiopulmonary bypass but also as a short-term assist device. The main purpose of this study was to examine the correlation between the thrombus formation factor and the Gyro C1E3 pumps. Seven pumps were implanted into 3 calves and evaluated for different periods of duration as a paracorporeal left ventricular assist device (LVAD). One pump was subjected to percutaneous cardiopulmonary support condition (PCPS) (total pressure head 500 mm Hg with a pump flow rate of 3 L/min). The anticoagulation treatment consisted of a continuous administration of heparin to maintain an activated clotting time (ACT) of 200-250 during the LVAD study and 250-300 during the PCPS study. After the experiment, the pumps were disassembled and examined. In cases where there were any blood-derived deposits inside the pumps, the dry weight of these thrombi that adhered to the bearing area of the pump was measured. A multiple correlation was attempted to speculate possible thrombus formation. The estimated dry weight of thrombi was calculated from pump flow rate, pumping day, motor speed, and activated clotting time. This equation was estimated dry weight of thrombi = 1.140 x pump flow rate -0.001 motor speed + 1.652 pumping time -0.041 x ACT + 2.198 R2 = 0.944. This study suggested that there was a possibility to calculate the amount of adhered thrombus formation from pump flow rate, motor speed, pumping day, and ACT.

Animals↗

Particles released from the Gyro C1E3 during simulated extracorporeal circulation.

Evaluation of released particles from the blood pump during extracorporeal circulation is an important aspect because the particles may cause microembolism. The Gyro C1E3 is a centrifugal blood pump that has an impeller suspended by double pivot bearings inside the housing; therefore, it is important to evaluate the released particles. The C1E3 was driven for 14 days to simulate clinical left ventricular assist device (LVAD) and percutaneous cardiopulmonary support (PCPS). Also, a roller pump was driven for 2 days as a comparison. Released particles were weighed and examined by SEM. After 14 days of pumping, the particles from the C1E3 were 238.6 microg in an LVAD condition. The particles with the roller pump were 270.2 microg after only 2 days. Average particle sizes with the roller pump and C1E3 were 3.7 and 0.6 microm, respectively. These results suggest that the Gyro C1E3 substantially reduces the risk of microembolism from released particles.

Biocompatible Materials↗

Impeller design for a miniaturized centrifugal blood pump.

The impeller design for a miniature centrifugal blood pump is an important consideration since the small diameter impeller requires higher rotational speed, which may cause more blood trauma compared to the larger diameter impeller. Three different impeller vanes (straight vanes with a height of 4 mm and 8 mm, and 8 mm curved vanes) of which the diameter was 35 mm were subjected to hydraulic performance and hemolysis tests in the same pump housing. Both straight vane impellers attained left ventricular assist condition (5 L/min against 100 mm Hg) at 2,900 rpm while the curved vane required 3,280 rpm. There was no significant hemolysis difference between the tall and short vanes. The curved impeller vanes did not exhibit sufficient hydraulic performance when compared to the straight vanes. The straight vane impellers, even with different heights, were incorporated into the same pump housings, and the vane heights did not drastically change the hydraulic performance or hemolysis.

Equipment Design↗

Analysis of the arterial blood pressure waveform during left ventricular nonpulsatile assistance in animal models.

When the rotary blood pump is used as a left ventricular assist device (LVAD), the arterial blood pressure waveform changes with the LVAD condition. Based on evidence from an in vitro study, the change of the arterial blood pressure waveform during left ventricular assistance was evaluated using animal models. After the left pleural cavity was opened through the fifth intercostal space under general anesthesia, a rotary blood pump was implanted as an LVAD into 6 healthy calves. The direct left carotid arterial blood pressure waveform was measured and recorded by an oscilloscope. The Fast Fourier Transform technique was utilized to analyze the arterial blood pressure waveform and calculate the pulsatility index (PI) and the pulse power index (PPI). Similar to the in vitro study, the PI and PPI decreased exponentially with the increase of the LVAD assist ratio. By using this analysis methodology, a physiologically effective ventricular assistance might be achieved.

Animals↗