Fetoscopic and ultrasound-guided decompression of the fetal trachea in a human fetus with Fraser syndrome and congenital high airway obstruction syndrome (CHAOS) from laryngeal atresia.

Congenital high airway obstruction syndrome (CHAOS) from laryngeal atresia bears a poor prognosis for hydropic fetuses owing to cardiac failure. We attempted percutaneous fetoscopic and ultrasound-guided tracheal decompression in a hydropic human fetus with CHAOS associated with Fraser syndrome. Percutaneous fetoscopic and ultrasound-guided tracheal decompression was performed using three trocars under general materno-fetal anesthesia at 19 + 5 weeks of gestation. Abnormal fetoplacental blood flow normalized within hours as a result of the intervention. Furthermore, a normalization of lung : heart size and lung echogenicity was observed within days. Resolution of hydrops was complete within 3 weeks. Premature rupture of membranes and premature contractions prompted emergency delivery of the fetus by ex-utero intrapartum treatment (EXIT) at 28 + 2 weeks of gestation. Following delivery, the lungs could be ventilated at low pressures and ambient oxygen concentration. Weaning from ventilation was achieved at 18 days of postnatal life. Our experience indicated that percutaneous fetoscopic and ultrasound-guided decompression of the fetal trachea is feasible and may permit normalization of hemodynamics in hydropic human fetuses with CHAOS from laryngeal atresia. The procedure may also result in normalization of heart : lung size and provide the time needed to regain the function of the overstretched diaphragm in this grave fetal condition.

Airway Obstruction↗

[Pedicled and free flaps for reconstruction in the head-neck region].

For reconstruction in the head-neck region, either pedicled or free flaps can be used depending on the site of origin and the place of reconstruction. Pedicled flaps have definite limitations, therefore, free transplants are becoming continuously more popular. Today, microvascular reanastomosed transplants are those most commonly used in reconstructive head-neck surgery. In this contribution, we present and explain the most important types of flaps and their indications.

Cervicoplasty↗

[Reconstruction of hypopharynx after pharyngolaryngectomy with U-shaped radial forearm flap].

BACKGROUND: After pharyngolaryngectomy reconstructive procedures of the upper digestive tract are necessary. Since the introduction of microvascular tissue transplantation jejunal loops proved to be a versatile transplant. Nevertheless it has some disadvantages as i. e. the increased donor morbidity, a rather high sensitivity to hypoxia and the tendency of shrinkage and formation of stenosis. METHOD: We perform the reconstruction of the hypopharynx with the radial forearm flap. The fasciocutaneous flap is harvested on the radial artery in a size of 12 x 6 cm in average and is sutured U-shaped paramedian to the prevertebral fascia. In addition the posterior wall of the oesophagus and the oropharynx have to be adapted to the prevertebral fascia. RESULTS: Between 1997 and 2001 we performed these reconstructions in 20 patients. In one case we found a complete flap necrosis, which required secondary reconstruction with a pectoralis major flap. In 2 patients we saw a stenosis at the junction to the oesophagus, which was treated by revision surgery and bougienage. In 18 patients swallowing was regular. 6 patients were able to learn oesophageal speech. CONCLUSION: The radial forearm flap in its U-shaped transposition to the prevertebral fascia represents a functionally good reconstructive procedure for the hypopharynx.

Esophageal Neoplasms↗

Transnasal and transsphenoidal MRI-guided biopsies of petroclival tumors.

Magnetic resonance imaging (MRI) allows excellent tissue characterization in the area of the petroclival region and can depict lesions not visualized with ultrasound or computed tomography (CT). The aim of this study was to demonstrate the clinical feasibility and utility of an interactive MR-guidance system to target and biopsy tumors in the petroclival region. MRI-guided biopsies of 10 patients with tumors in the clivus and petrous apex were performed in an open 0.5-T MR system. Lesions were targeted through a transsphenoidal or transnasal approach. Imaging during biopsies was achieved by a combination of standard and interactive mode. T1-weighted spin-echo, T2-weighted fast spin-echo (FSE), and three-dimensional T1-weighted gradient-echo (GRE) scans (standard mode) were selected to provide optimal tissue characterization for both the lesion and surrounding structures and varied according to the anatomic site. For interactive imaging, T1-weighted GRE and T2-weighted FSE sequences were used. We performed MRI-guided transsphenoidal biopsies in 10 patients who had lesions identified by CT (n = 5) and/or MRI (n = 10). The indications for biopsies were to differentiate between suspected malignant processes (n = 4 ) and benign processes (n = 6). Lesions adjacent to structures like the internal carotid artery were accurately targeted in particular. All biopsies were performed successfully and were the basis for selection of further treatment. No complications occurred during the procedures. An open MR system allows interactive control of biopsies in the area of the petroclival region, providing maximum patient safety and diagnostic accuracy not possible in other systems. The advantages of MRI tissue characterization are combined with an interactive, one-step method of localization and targeting, as well as tissue sampling. J. Magn. Reson. Imaging 2001;13:3-11.

Biopsy, Needle↗

The use of open MRI in otorhinolaryngology: initial experience.

Intraoperative imaging in head and neck surgery is a useful tool in many situations. In addition to being helpful for intraoperative orientation, real-time imaging enables visualization of the progress of surgery and the completeness of tumor resection. Regions in the head and neck to which access is difficult, and which therefore have a high incidence of morbidity and risk for the patient, can be approached more easily and safely in an open MRI than in a conventional way. Interventions in the open MRI (Signa SP, 0.5 Tesla) were performed with nonmagnetic instruments and an MR-safe microscope. For intraoperative navigation, the integrated FlashPoint system is helpful, because it allows targeting of the tumor by a calculated virtual line. T1W spin-echo, T2W fast spin-echo, and 3D T1W gradient-echo sequences were used for high-resolution imaging. Real-time imaging is achieved by fast multiplanar spoiled gradient-echo sequences or T2 single-shot fast spin-echo sequences. From 1996 to the present, we biopsied 17 petroclival tumors, performed paranasal sinus surgery in five cases, biopsied two neck masses, and inserted tubes for brachytherapy in 12 cases. No complications were observed. In all surgical procedures, a good resolution was obtained with MRI, especially for soft-tissue structures. The tumor could be targeted exactly, and all specimens revealed the relevant histology. In paranasal sinus surgery, however, the success rate was lower because it was difficult to distinguish blood from pathologic tissue. The insertion of tubes for brachytherapy was successful in all cases. It was possible to apply the tubes parallel to each other, 1 cm apart. Relevant biopsies could be taken of both neck masses. The indications for the use of open MRI in otorhinolaryngology are biopsies of tumors in regions that are difficult to approach, such as the petrous apex and petroclival region, the parapharyngeal space, and the orbit. Furthermore, the open MRI can be useful in paranasal sinus surgery, in the evaluation of tissue resection, and in the detection of the anatomy of delicate structures such as the internal carotid artery, the skull base, and the orbit. In addition, active navigation in the open MRI is possible with the integrated FlashPoint system. The advantage over conventional navigation systems lies in the possibility of real-time imaging, which allows detection of tissue changes occurring during the procedure.

Biopsy↗

Case report. Mycotic arteritis due to Aspergillus fumigatus in a diabetic with retrobulbar aspergillosis and mycotic meningitis.

A 74-year-old man with diabetes mellitus type II, retinopathy and polyneuropathy suffered from exophthalmus, ptosis and diplopia. Magnetic resonance imaging and computer tomography showed a space-occupying process in the right orbital apex. An extranasal ethmoidectomy accompanied by an orbitotomia revealed the presence of septated hyphae. Aspergillus fumigatus was grown from the tissue. After surgical removal of the fungal masses, therapy with amphotericin B (1 mg kg(-1) body weight) plus itraconazole (Sempera, 200 mg per day) over 6 weeks was initiated. Five months later the patient's condition deteriorated again, with vomiting, nausea and pain behind the right eye plus increasing exophthalmus. Antifungal therapy was started again with amphotericin B and 5-fluorocytosine. Neutropenia did not occur. The patient became somnolent and deteriorated, a meningitis was suggested. Aspergillus antigen (titre 1:2, Pastorex) was detected in liquor. Anti-Aspergillus antibodies were not detectable. Both the right eye and retrobulbar fungal masses were eradicated by means of an exenteratio bulbi et orbitae. However, renal insufficiency and an apallic syndrome developed and the patient died. At autopsy, a mycotic aneurysm of the arteria carotis interna dextra was detected. The mycotic vasculitis of this aneurysm had caused a rupture of the blood vessel followed by a massive subarachnoidal haemorrhage. In addition, severe mycotic sphenoidal sinusitis and aspergillosis of the right orbit were seen, which had led to a bifrontal meningitis.

Aged↗

Magnetic resonance imaging--guided biopsies of the petrous apex and petroclival region.

OBJECTIVE: To analyze the advantages in safety and precision of biopsies of the petrous apex and petroclival region using open magnetic resonance imaging (MRI). SETTING: The University of Leipzig Medical Center. PATIENTS: Biopsies were taken in 13 patients with tumors of the petrous apex and petroclival region. INTERVENTION: With the patient in the 0.5-T intraoperative MRI system (Signa SP; General Electric Medical Systems, Boston, MA, U.S.A.), biopsies were taken from the petrous apex and the petroclival region under imaging control by transseptal, transsphenoidal access. The region of interest was approached with a virtual pointer (Flashpoint Position Encoder; Image Guided Technologies, U.S.A.) and marked with a gadolinium-filled pointer. RESULTS: In all patients, the authors obtained enough tissue for histologic study, which also proved to be the suspected tumor. One patient had a bone cyst, another had a malignant lymphoma, and another two a cholesterol granuloma originating from the petrous apex. Three other patients had metastases (carcinoma of the breast, bronchial carcinoma, and unknown origin). Three patients had a meningioma, and another three a chordoma. The authors did not see any postoperative complications. CONCLUSIONS: In the authors' experience, the transsphenoidal access is favorable for approaching and sampling lesions of the petrous apex and the petroclival region. This route, however, is disadvantageous because the course of the internal carotid artery and the brainstem narrow the surgical space to the petrous apex. Open MRI in these cases is very useful because it allows a safe approach to the tumor by navigation and by visualizing the anatomic structures in real-time imaging.

Adult↗

[Neuromuscular reinnervation of mimetic muscles. A histomorphologic study of the zygomatic muscle of the rabbit].

To evaluate occurrences of reinnervation and degeneration, the portio auricularis of the zygomatic muscle was reinnervated (either primary or secondary reinnervation) with an interval of 6 weeks, using a neuromuscular transplant of the sternohyoid muscle, which was left at the ansa hypoglossi. Histological examination was performed 6 and 12 weeks later. Enzymatic stains for myofibrillar ATPase were used for differentiation of muscle fibre types. Histomorphological features of denervation and reinnervation were analysed. Six weeks after denervation and primary neuromuscular transplantation, type grouping in regions close to the transplanted muscle were detectable as signs of reinnervation. After a period of 12 weeks, the progressing reinnervation was proved by type grouping in distal areas of the muscle far from the area of transplantation. At the same time, differentiation of fibre typing in the type grouping areas increased. All denervated and reinnervated muscles had pathological variations of fibre diameter. Primary reinnervated muscles showed tendency of normalization in variation of diameter. Compared with primary reinnervated muscles, secondary reinnervated muscles with an interval of 6 weeks showed pronounced polymorphology of fibres and a high pathological increase of the variation of fibre diameters. The interfascicular space was significantly spread. The tendency of reinnervation with incidence of fibre type grouping was comparable to primary reinnervated muscles and also occurred 6 weeks after transplantation.

Animals↗

In vivo experiments in the cat with an implantable piezoelectric hearing aid transducer.

We have recently developed an implantable piezoelectric hearing aid transducer that is suitable for implantation in patients with sensorineural hearing loss. The transducer does not transmit sound but conducts micromechanical vibrations to the cochlea. In ten cat ears we investigated the efficiency of the implantable transducer with respect to the direct transfer of vibrations within the audible frequency range via the ossicles to the cochlea or directly into the vestibule. The acoustically evoked brainstem potential (ABR) threshold was determined prior to implantation, and the middle ear was then opened and the piezoelectric transducer coupled to the ossicles or to the perilymph. Acoustically evoked brainstem potentials were recorded following stimulation at the umbo, long process of the incus, stapes head, stapes foot plate, and in the vestibulum. Comparisons of the acoustically and mechanically evoked thresholds revealed a good correlation of the two stimulation levels. An electrical transducer voltage of 1 V(RMS) produced equivalent sound pressure levels (SPL) of 100-128 dB at the tympanic membrane. To assess the hearing we compared stimulus-dependent latencies of the early potentials (peaks P1-P5) and thresholds. This evaluation was based on four ears with normal hearing in which the piezoelectric transducer was coupled to the long process of the incus. The mean values of the latencies and their scattering range correlated extremely well in the two stimulation modes. They were nearly identical when the equivalent SPL of 100 dB was assigned to the maximally applied electrical level of 0 dB. These in vitro and in vivo findings demonstrate that the characteristics of the transducer warrant its development further from the prototype stage to become a component of an implantable hearing device for patients with sensorineural hearing loss.

Acoustic Stimulation↗

Human studies of a piezoelectric transducer and a microphone for a totally implantable electronic hearing device.

OBJECTIVE: For the surgical treatment of patients with moderate and severe sensorineural hearing loss, the authors have developed a totally implantable hearing device, the totally integrated cochlea amplifier (TICA). To evaluate the effectiveness of transducer and microphone of this device, three separate human studies were conducted. STUDY DESIGN: The first study using transducer prototypes involved self experiments in investigators with normal hearing. The second study used the transducer prototypes in patients with hearing loss, and the third study involved the temporary implantation of the final transducer prototype and microphone in patients undergoing otologic surgery. PATIENTS: In routine middle ear surgery, transducer prototypes were coupled to the ossicular chain of 28 patients. In addition to the transducer, in 5 patients the microphone was placed beneath the skin of the auditory canal, allowing the skin to cover the microphone membrane completely. RESULTS: The piezoelectric transducer reached an equivalent sound pressure level of 145 dB SPL < or =10 kHz. The dynamics for music reached 32 dB, which was identical with the results of the preoperative investigations using high-fidelity headsets (33 dB). The low nonlinear distortions of <0.1% and the frequency range of 10 kHz are reflected in the positive evaluation of the sound quality by 84% of the patients involved. When phonetically balanced speech material and music were presented under free field conditions at a sound level of 65 dB SPL, understanding of the phonetically balanced speech material was 100%. Most patients judged the presentations of music as clear and undistorted with all broadband components. CONCLUSIONS: Data in humans on the performance of the two main components of the TICA implant, the transducer and the microphone, are reported.

Amplifiers, Electronic↗

[Use of open MRI in head-neck surgery].

The vertical open MRI (Signa SP, 0, 5 Tesla) is ideal for interventional diagnosis and therapy. From our point of view indications in Otorhinolaryngology are biopsies of tumours which are difficult to access such as the petrous apex and the petroclival region, the parapharyngeal space and neck and the orbit. Furthermore the open MRI is useful in the surgery of paranasal sinuses, in the evaluation of tissue-resection and helpful in detection of the anatomy of delicate structures as the internal carotid artery, the skull-base and the orbit. Also navigation in open MRI is possible for example with a flash-point-system. The advantage to conventional navigation systems is the possibility of real-time-imaging, which allows detection of tissue shift occurring during the procedure. We report about our experience with ten biopsies of the petrous apex and the petroclival junction and two biopsy of the parapharyngeal space and the neck. Further experience was gained with MR guided placement of afterloading tubes into large neck metastases in three cases and microscopic surgery of paranasal sinuses in five cases. In all operative procedures an excellent resolution was found especially for soft tissue structures as for example blood vessels. With the aid of special pointer systems or artefacts by surgical instruments all relevant anatomical structures could be detected intraoperatively, concerning normal and pathologic tissue. Thus open MRI proved to be a helpful instrument in these operative procedures.

Adult↗

[In vivo studies of a piezoelectric implantable hearing aid transducer in the cat].

Recently, we presented an implantable piezoelectrical hearing aid transducer. Its characteristics make it suitable for implantation in patients with sensorineural hearing loss. The transducer transmits micromechanical vibrations instead of sound into the hearing organ. Efficiency of the transducer implant was investigated in ten cat ears. After determining preoperative (acoustical) BERA threshold, the middle ear was opened and the piezoelectrical transducer coupled to various ossicles or the perilymph. BERA responses were recorded following stimulation of umbo, long incus process, stapes head, stapes foot plate, and vestibulum. By comparing the acoustical and mechanical threshold, a correlation was found between the stimulus level of acoustical and mechanical stimulation. An electrical transducer voltage of 1 Vrms was equivalent to sound-pressure levels between 100 and 128 dB SPL at the tympanic membrane. To judge hearing impression, stimulus-dependent latencies of the early acoustically and mechanically evoked potentials (waves P1 to P5) and their thresholds were analyzed. After coupling the piezoelectrical transducer to the long incus process, latencies corresponded well to stimulation. They were almost completely similar when the equivalent sound-pressure level of 100 dB SPL was achieved by the transducer voltage level.

Animals↗

[Intraoperative evaluation of signal transduction of prototypes of implantable hearing aid transducers in the human].

During routine middle ear surgery prototypes of implantable piezoelectric hearing aid transducers were coupled to the ossicular chain of 28 patients. Pure tone thresholds in a broad frequency range (250 Hz-8 kHz) and perception of music were the basis of psychoacoustic evaluation of the transfer properties of the prototypes in this human study. The piezoelectric transducer reached an equivalent transducer sound-pressure level of up to 145 dB SPL and frequencies of 10 kHz. The dynamics for music reached 32 dB, which was identical with the results of the preoperative investigations using hi-fi headsets (33 dB). The low nonlinear distortions of around 0.1% and the frequency range up to 10 kHz are reflected in the positive evaluation of sound quality by 84% of the patients involved. The study is the basis for realizing a piezoelectric transducer designed for routine clinical implantations. The transducer is thought to be part of a totally implantable future hearing aid for rehabilitation of moderate and severe sensory neural hearing loss predominantly in the middle and high frequency range.

Adult↗