PubMed Health⌕ Search

Biomedical subjects

S Kolesnik

Publications and source records attributed to S Kolesnik.

8 recordsLinked to original sources

Temperature stabilization of alanine dosimeters used for food processing and sterilization

The International Atomic Energy Agency has established a dose quality audit service for radiation processing facilities. The objective of the service is to provide an independent check on the routine dosimetry system in use at the facility. The audit service is based on the use of alanine EPR dosimetry. Generally, alanine dosimeters are irradiated at the facility together with a product, and the response is then analyzed at the IAEA laboratory. Practice of the audit service has shown that the main uncertainty in alanine dosimetry is due to absence of temperature control at the irradiation facilities. Here, a method for stabilizing the temperature of the dosimeter during irradiation is proposed.

Journal Article↗

Anthropometry in body composition. An overview.

Anthropometry is a simple reliable method for quantifying body size and proportions by measuring body length, width, circumference (C), and skinfold thickness (SF). More than 19 sites for SF, 17 for C, 11 for width, and 9 for length have been included in equations to predict body fat percent with a standard error of estimate (SEE) range of +/- 3% to +/- 11% of the mean of the criterion measurement. Recent studies indicate that not only total body fat, but also regional fat and skeletal muscle, can be predicted from anthropometrics. Our Rosetta database supports the thesis that sex, age, ethnicity, and site influence anthropometric predictions; the prediction reliabilities are consistently higher for Whites than for other ethnic groups, and also by axial than by peripheral sites (biceps and calf). The reliability of anthropometrics depends on standardizing the caliper and site of measurement, and upon the measuring skill of the anthropometrist. A reproducibility of +/- 2% for C and +/- 10% for SF measurements usually is required to certify the anthropometrist.

Adipose Tissue↗

The first international intercomparison of EPR-dosimetry with teeth: first results.

Intercomparison of EPR-dosimetric techniques using tooth enamel had been performed in order to check whether the results produced by different laboratories are consistent and accurate. Participants were supposed to evaluate doses applied to pulverized enamel samples, using routine techniques from their laboratories. The intercomparison has demonstrated a great variety of methods used for dose reconstruction. Peculiarities of experimental approaches are discussed systematically in terms of procedure for recording the EPR-spectra, determination of the amplitude of the radiation induced signal, determination of the dose, and error propagation.

Dental Enamel↗