High wall shear stress measured by magnetic resonance is a predictor of restenosis in the femoral-artery after balloon angioplasty.

AIM: Wall shear stress (WSS) has been implied in the pathogenesis of restenosis after percutaneous transluminal angioplasty (PTA). Aims of the present study were to calculate WSS in the superficial femoral artery (SFA) from magnetic resonance imaging (MRI) and from duplex sonography in healthy controls and in patients after PTA of the SFA to evaluate the predictive value of WSS for restenosis. METHODS: WSS was assessed by calculating the slope of velocity profiles at the vessel wall from data obtained with velocity encoded cine MR and with duplex using the formula: Shear stress=4xblood viscosityxpeak blood velocity/internal diameter. Seventeen patients were studied 1 day after successful PTA of the SFA. Restenosis was determined by duplex ultrasound at the 6-months follow-up visit. RESULTS: In healthy controls WSS values calculated from MRI and from duplex were similar (1.86+/-0.35 N/m2 vs 1.88+/-0.34 N/m2, n.s.). In patients the values obtained with duplex were higher than those obtained with MRI (4.1+/-2.3 N/m2 vs 2.4+/-1.2 N/m2, p=0.002). With both methods post-interventional WSS was higher in patients developing restenosis (duplex 5.4+/-2.2 N/m2, MRI 3.1+/-0.9 N/m2) than in those without restenosis (duplex 2.7+/-1.4 N/m2, MRI 1.5+/-0.7 N/m2) and was revealed to be an independent predictor of restenosis (p=0.03). CONCLUSIONS: This is the first study demonstrating that increased post-interventional WSS in the SFA is predictive for restenosis. WSS values obtained with MRI and duplex were different in patients, however with both methods higher WSS was associated with restenosis.

Adult↗

Coronary flow quantification by Fourier velocity encoded MRI.

Recently, the feasibility of measuring coronary blood flow using fast magnetic resonance (MR) techniques was reported. Thus, MR holds potential to non-invasively assess significance of coronary stenosis. However, the accurate determination of flow and vessel area still remains challenging. High spatial and temporal resolution is required to assess reliable flow profiles within the coronary arteries. For this purpose, Fourier velocity encoding (FVE) was implemented with a small number of encoding steps. Simulations and in-vitro experiments have been performed to demonstrate the benefit of FVE for flow quantification. Further, initial volunteer measurements have shown its potential for invivo application.

Blood Flow Velocity↗

Visualization of flow patterns distal to aortic valve prostheses in humans using a fast approach for cine 3D velocity mapping.

The fluid dynamic performance of mechanical heart valves differs from normal valves and thus is considered related to late clinical complications in patients. Since flow patterns evolving around heart valves are complex in space and time, flow visualization based on time-resolved 3D velocity data might add important information regarding the performance of specific valve designs in vivo. However, previous cine 3D techniques for three-directional phase-contrast velocity mapping suffer from long scan duration and therefore might hamper assessment in patients. A hybrid 3D phase-contrast sequence combining segmented k-space acquisition with short EPI readout trains is presented with its validation in vitro. The technique was applied to study flow patterns downstream from a bileaflet aortic prosthesis in six patients. Navigator echoes were incorporated for respiratory motion compensation. Before flow visualization, spurious phase errors due to concomitant gradient fields and eddy currents were corrected. Flow visualization was based on particle paths and animated velocity vector plots. Dedicated algorithms for particle path integration were implemented to account for the considerable motion of the ascending aorta during the cardiac cycle. A distinct flow pattern reflecting the valve design was observed closest to the valve during early flow acceleration. Reverse flow occurred adjacent to high velocity jets and above the hinge housings. Later in systole, flow became confined to the central vessel area and reverse flow along the inner aortic curvature developed. Further downstream from the valve, flow patterns varied considerably among patients, indicating the impact of varying aortic anatomy in vivo. It is concluded that MR velocity mapping is a potential tool for studying 3D flow patterns evolving around heart valve prostheses in humans. J. Magn. Reson. Imaging 2001;13:690-698.

Aged↗

Aortic and mitral regurgitation: quantification using moving slice velocity mapping.

Comprehensive assessment of the severity of valvular insufficiency includes quantification of regurgitant volumes. Previous methods lack reliable slice positioning with respect to the valve and are prone to velocity offsets due to through-plane motion of the valvular plane of the heart. Recently, the moving slice velocity mapping technique was proposed. In this study, the technique was applied for quantification of mitral and aortic regurgitation. Time-efficient navigator-based respiratory artifact suppression was achieved by implementing a prospective k-space reordering scheme in conjunction with slice position correction. Twelve patients with aortic insufficiency and three patients with mitral insufficiency were studied. Aortic regurgitant volumes were calculated from diastolic velocities mapped with a moving slice 5 mm distal to the aortic valve annulus. Mitral regurgitant flow was indirectly assessed by measuring mitral inflow at the level of the mitral annulus and net aortic outflow. Regurgitant fractions, derived from velocity data corrected for through-plane motion, were compared to data without correction for through-plane motion. In patients with mild and moderate aortic regurgitation, regurgitant fractions differed by 60% and 15%, on average, when comparing corrected and uncorrected data, respectively. Differences in severe aortic regurgitation were less (7%). Due to the large orifice area of the mitral valve, differences were still substantial in moderate-to-severe mitral regurgitation (19%). The moving slice velocity mapping technique was successfully applied in patients with aortic and mitral regurgitation. The importance of correction for valvular through-plane motion is demonstrated.

Adult↗

Heart motion-adapted MR velocity mapping of blood velocity distribution downstream of aortic valve prostheses: initial experience.

PURPOSE: To investigate blood flow velocities and shear rates at two distances downstream of an artificial aortic valve in patients. MATERIALS AND METHODS: Blood velocity was quantified downstream of the valve prosthesis (for replacement after aortic valve stenosis or combined stenosis and regurgitation) in 10 patients by using a magnetic resonance (MR) cine velocity mapping method in which the imaging section position is adapted according to the excursion of the valvular plane of the heart. Two acquisitions were performed to display the blood velocity distributions one-fourth valve diameter and one valve diameter downstream of the valve and to quantify blood volumes and shear rates. RESULTS: The velocity profiles measured during flow acceleration one-fourth valve diameter downstream were characterized by a distinct pattern of two lateral jets and one central jet of antegrade flow. High shear rates were found along the leaflet tips. The profiles obtained one valve diameter downstream were skewed, with varying velocity patterns among patients. Peak shear rates were found close to the vessel wall. With correction for through-plane motion of the valve, the mean apparent regurgitant fraction (+/- SD) was 14% +/- 6; the mean regurgitant fraction without correction was 9% +/- 5. CONCLUSION: The described noninvasive procedure for velocity mapping enables measurements close to the valve and thus evaluation of blood flow patterns with respect to valve design in humans.

Adult↗

Automatic vessel segmentation using active contours in cine phase contrast flow measurements.

The segmentation of images obtained by cine magnetic resonance (MR) phase contrast velocity mapping using manual or semi-automated methods is a time consuming and observer-dependent process that still hampers the use of flow quantification in a clinical setting. A fully automatic segmentation method based on active contour model algorithms for defining vessel boundaries has been developed. For segmentation, the phase image, in addition to the magnitude image, is used to address image distortions frequently seen in the magnitude image of disturbed flow fields. A modified definition for the active contour model is introduced to reduce the influence of missing or spurious edge information of the vessel wall. The method was evaluated on flow phantom data and on in vivo images acquired in the ascending aorta of humans. Phantom experiments resulted in an error of 0.8% in assessing the luminal area of a flow phantom equipped with an artificial heart valve. Blinded evaluation of the volume flow rates from automatic vs. manual segmentation of gradient echo (FFE) phase contrast images obtained in vivo resulted in a mean difference of -0.9 +/- 3%. The mean difference from automatic vs. manual segmentation of images acquired with a hybrid phase contrast sequence (TFEPI) within a single breath-hold was -0.9 +/- 6%.

Adult↗

Heart motion adapted cine phase-contrast flow measurements through the aortic valve.

A method for magnetic resonance cine velocity mapping through heart valves with adaptation of both slice offset and angulation according to the motion of the valvular plane of the heart is presented. By means of a subtractive labeling technique, basal myocardial markers are obtained and automatically extracted for quantification of heart motion at the valvular level. The captured excursion of the basal plane is used to calculate the slice offset and angulation of each required time frame for cine velocity mapping. Through-plane velocity offsets are corrected by subtracting velocities introduced by basal plane motion from the measured velocities. For evaluation of the method, flow measurements downstream from the aortic valve were performed both with and without slice adaptation in 11 healthy volunteers and in four patients with aortic regurgitation. Maximum through-plane motion at the aortic root level as calculated from the labeled markers averaged 8.9 mm in the volunteers and 6.5 mm in the patients. The left coronary root was visible in 2-4 (mean: 2.2) time frames during early diastole when imaging with a spatially fixed slice. Time frames obtained with slice adaptation did not contain the coronary roots. Motion correction increased the apparent regurgitant volume by 5.7 +/- 0.4 ml for patients with clinical aortic regurgitation, for an increase of approximately 50%. The proposed method provides flow measurements with correction for through-plane motion perpendicular to the aortic root between the valvular annulus and the coronary ostia throughout the cardiac cycle. Magn Reson Med 42:970-978, 1999.

Adult↗

Quantitative abdominal aortic flow measurements at controlled levels of ergometer exercise.

Measuring the exercise-induced flow changes in the arteries of the body is a major challenge. The use of quantitative MR flow measurements for this purpose is hampered by movement artifacts and ECG triggering problems. To quantify exercise-induced flow changes in the abdominal aorta, we applied a fast hybrid phase contrast sequence with K-space segmentation and echo planar imaging readouts during a 12 heart beat, single breathhold post exercise scanning window after ergometer exercise in nine volunteers. Central k-space was acquired first. The changes in heart rate throughout the scanning window were quantified. The mean decrease in heart rate after six heart beats post exercise was less than 4% and less than 14% after 11 heart beats indicating that the exercise state was very well represented during the acquisition of central k-space. Abdominal aortic flow increased from 1.4+/-0.3 l/min at rest to 7.9+/-1.1 l/min at 131 watt. Retrograde flow reached a maximum value of 1.2 l/min at rest, and lasted 140 ms on average. Only for one out of the nine volunteers was there any retrograde flow present during exercise (at 33 watt and 65 watt exercise). It was concluded that retrograde flow patterns in the abdominal aorta associated with oscillating wall shear stresses and development of atherosclerosis disappeared with increasing levels of exercise. The feasibility of using fast quantitative phase contrast measurements during a post exercise scanning window to represent controlled exercise levels was demonstrated.

Adult↗

Quantitation of circumferential subpixel vessel wall position and wall shear stress by multiple sectored three-dimensional paraboloid modeling of velocity encoded cine MR.

Methods are lacking for accurate, noninvasive circumferential edge detection and wall shear stress calculation. Using standard MR phase contrast sequences, parts of the velocity profiles were fitted to a multiple sectored three-dimensional paraboloid model enabling exact calculation of vessel wall position and wall shear stress in 24 locations evenly distributed around the luminal vessel wall. The model was evaluated by in vitro scans and computer simulations and applied to the common carotid artery of humans. In vitro, the luminal area of a glass tube was assessed with an error of 0.9%. Computer simulations of peak systolic data revealed errors of +/-0.9% (vessel area) and +/-3.25% (wall shear stress). The in vivo results showed substantial difference between anterior and posterior wall shear stress values due to skewed velocity profiles. A new noninvasive method for highly accurate measurement of circumferential subpixel vessel wall position and wall shear stress has been developed.

Adult↗

Accurate noninvasive quantitation of blood flow, cross-sectional lumen vessel area and wall shear stress by three-dimensional paraboloid modeling of magnetic resonance imaging velocity data.

OBJECTIVES: We present a new method in which a priori knowledge of the blood velocity fields within the boundary layer at the vessel wall, combined with acquisition of high resolution magnetic resonance imaging (MRI) blood velocity data, allow exact modeling at the subpixel level. BACKGROUND: Methods are lacking for accurate, noninvasive estimation of blood flow, dynamic cross-sectional lumen vessel area and wall shear stress. METHODS: Using standard acquisition of MRI blood flow velocity data, we fitted all data points (n = 69) within the boundary layer of the velocity profile to a three-dimensional paraboloid, which enabled calculation of absolute volume blood flow, circumferential vessel wall position, lumen vessel area and wall shear stress. The method was tested in a 8.00 +/ 0.01-mm diameter glass tube model and applied in vivo to the common carotid artery of seven volunteers. RESULTS: In vitro the lumen area was assessed with a mean error of 0.6%. The 95% confidence interval included the specified tube dimensions. Common carotid mean blood flow was 7.42 ml/s, and mean (standard error) diastolic/systolic vessel area was 33.25 (0.72 [2.2%])/43.46 (0.65 [1.5%]) mm2. Mean/peak wall shear stress was 0.95 (0.04 [4.2%])/2.56 (0.08 [3.1%]) N/m2. CONCLUSIONS: We describe a new noninvasive method for highly accurate estimation of blood flow, cross-sectional lumen vessel area and wall shear stress. In vitro results and statistical analysis demonstrate the feasibility of the method, and the first in vivo results are comparable to published data.

Adult↗

Automatic accurate non-invasive quantitation of blood flow, cross-sectional vessel area, and wall shear stress by modelling of magnetic resonance velocity data.

OBJECTIVES: To apply a new, automatic and non-invasive method for quantification of blood flow, dynamic cross-sectional vessel area, and wall shear stress (WSS) by in vivo magnetic resonance velocity mapping of normal subjects. DESIGN: Prospective, open study. MATERIALS: Six young volunteers. METHODS: A three-dimensional paraboloid model enabling automatic determination of blood flow, vessel distensibility and WSS was applied to blood velocity determinations in the common carotid artery. Blood flow was also determined by a manual edge detection method. RESULTS: Using the new method, the common carotid mean blood flow was 7.28 (5.61-9.63) (mean (range)) ml/s. By the manual-method blood flow was 7.21 (5.55-9.60) ml/s. Mean luminal vessel area was 26% larger in peak systole than in diastole. Mean/peak WSS was 0.82/2.28 N/m2. Manually and automatically determined flows correlated (r2 = 0.998, p < 0.0001). WSS and peak centre velocity were associated (r2 = 0.805, p < 0.0001). CONCLUSIONS: Blood flow, luminal vessel area dilatation, and WSS can be determined by the automatic three-dimensional paraboloid method. The hypothesis of association between peak centre velocity and WSS was not contradicted by the results of the present study.

Adult↗