PubMed Health⌕ Search

Biomedical subjects

S L Pohl

Publications and source records attributed to S L Pohl.

49 records · Page 3Linked to original sources

The reaction of glucagon with its receptor: evidence for discrete regions of activity and binding in the glucagon molecule.

Des-histidine-glucagon (DH-glucagon, glucagon(2-29)) does not activate the glucagon-sensitive adenylate cyclase system present in either liver plasma membranes or in fat-cell "ghosts", but inhibits the response of these systems to submaximal concentrations of glucagon. DH-glucagon also inhibits, competitively, the binding of [(125)I]glucagon to its receptor in liver plasma membranes. Amino-terminal fragments of glucagon (glucagon(1-21), glucagon(1-23)) and carboxy-terminal fragments (glucagon(20-29), glucagon(22-29)) failed to activate adenylate cyclase, to inhibit the response of the enzyme to glucagon, or to compete with labeled glucagon at its receptor. It is concluded that the amino-terminal histidine residue of glucagon is essential for biological activity and that a hydrophobic near-carboxy-terminal region (residues 22-27) is essential for binding of glucagon to its receptor. Amino-terminal histidine may also contribute to the binding of glucagon, since the apparent affinity of DH-glucagon for the receptor is only about one-sixth that of glucagon. Thus, essentially the entire molecule of glucagon must be considered to be the biologically active species.Because, as shown elsewhere, the binding of glucagon to its receptor shows characteristics of hydrophobic bonding, and because certain detergents induce conformational changes in the carboxy-terminal binding region of glucagon, the binding is probably of a lipophilic type.

Adenylyl Cyclases↗

Glucagon-sensitive adenyl cylase in plasma membrane of hepatic parenchymal cells.

The plasma membrane of hepatic parenchymal cells contains an adenyl cyclase system that is stimulated by glucagon. Adrenocorticotropin and epinephrine do not stimulate this adenyl cyclase, and very little cyclic phospho-diesterase activity is present in the membrane. These findings support the concept that glucagon exerts its regulatory action in the liver by stimulating adenyl cyclase activity in the plasma membrane.

Adenine Nucleotides↗

Evaluating clinical accuracy of systems for self-monitoring of blood glucose.

Although the scientific literature contains numerous reports of the statistical accuracy of systems for self-monitoring of blood glucose (SMBG), most of these studies determine accuracy in ways that may not be clinically useful. We have developed an error grid analysis (EGA), which describes the clinical accuracy of SMBG systems over the entire range of blood glucose values, taking into account 1) the absolute value of the system-generated glucose value, 2) the absolute value of the reference blood glucose value, 3) the relative difference between these two values, and 4) the clinical significance of this difference. The EGA of accuracy of five different reflectance meters (Eyetone, Dextrometer, Glucometer I, Glucometer II, Memory Glucometer II), a visually interpretable glucose reagent strip (Glucostix), and filter-paper spot glucose determinations is presented. In addition, reanalyses of a laboratory comparison of three reflectance meters (Accucheck II, Glucometer II, Glucoscan 9000) and of two previously published studies comparing the accuracy of five different reflectance meters with EGA is described. EGA provides the practitioner and the researcher with a clinically meaningful method for evaluating the accuracy of blood glucose values generated with various monitoring systems and for analyzing the clinical implications of previously published data.

Blood Glucose↗

Measurement of glycosylated hemoglobins using boronate affinity chromatography.

A boronate affinity column method for the measurement of glycosylated hemoglobins was evaluated. In the procedure the glycosylated hemoglobins were bound by immobilized boronic acid to separate them from nonglycosylated hemoglobins. Elution of bound glycosylated hemoglobins was carried out with sorbitol buffer, and the absorbance was read at 414 nm. The method was linear to a glycosylated hemoglobin concentration of at least 20 percent. The precision of the method ranged from 1.2 to 2.8 percent (C.V.) within-run, and 3.4 to 5.3 percent day-to-day. The reference interval was 4.8 to 6.4 percent. The method correlated with a cation exchange resin mini-column method (r = 0.94) and a colorimetric method (r = 0.93) but results from the boronate affinity method were higher in diabetic patients. The measured glycosylated hemoglobin was significantly correlated with estimated one-day-mean plasma glucose in diabetic patients (r = 0.54, n = 52, p less than 0.002). The affinity method provides an attractive alternative to earlier methods for measuring glycosylated hemoglobins.

Adolescent↗