PubMed Health⌕ Search

Biomedical subjects

S L Woo

Publications and source records attributed to S L Woo.

At least 55 records · Page 3Linked to original sources

Cytokine-induced tendinitis: a preliminary study in rabbits.

This study was designed to determine the effects of a single injection of a species-specific preparation of cytokines into rabbit patellar tendons and to compare the results with a known model of tendinitis, the collagenase-injection model. New Zealand White rabbits were divided into two groups and two time periods (4 and 16 weeks) and injected in the midsubstance of the right patellar tendon with either cytokines or collagenase under ultrasound guidance to confirm intratendinous needle placement. The left patellar tendon was injected with 0.025 ml of saline solution and served as a control. The rabbits were returned to cage activity after injection. At death, two rabbits in each group underwent histological analysis; the remaining eight animals in each time frame were evaluated biomechanically and then biochemically with use of the patella/whole patellar tendon/tibia complex. Histologic results at 4 weeks in the tendons injected with cytokines demonstrated increased cellularity, which was resolving by 16 weeks. The matrix appeared unchanged. The tendons injected with collagenase demonstrated increased angiogenesis of the matrix, hypercellularity, and fibrosis around the tendon at 4 weeks. At 16 weeks, myxoid changes, focal fibrosis, and collagen-bundle disarray with persistent increase in cellularity were noted. Biomechanically, a significant decrease in ultimate load at 16 weeks was seen in the tendons injected with cytokines but no change was seen in cross-sectional area. The tendons injected with collagenase demonstrated a significant increase in cross-sectional area at 4 and 16 weeks compared with those injected with cytokines. Biochemically, there was no significant difference in collagen content between the two groups at 4 or 16 weeks but the tendons injected with collagenase demonstrated a significant increase in crosslinking at 16 weeks. Our conclusion is that the tendons injected with the cytokine preparation represent a model of mild, seemingly reversible tendon injury. The cytokine preparation produces no matrix damage or evidence of collagen degradation and is species specific.

Animals↗

In situ forces in the human posterior cruciate ligament in response to muscle loads: a cadaveric study.

The objectives of this study were to determine the effects of hamstrings and quadriceps muscle loads on knee kinematics and in situ forces in the posterior cruciate ligament of the knee and to evaluate how the effects of these muscle loads change with knee flexion. Nine human cadaveric knees were studied with a robotic manipulator/universal force-moment sensor testing system. The knees were subjected to an isolated hamstrings load (40 N to both the biceps and the semimembranosus), a combined hamstrings and quadriceps load (the hamstrings load and a 200-N quadriceps load), and an isolated quadriceps load of 200 N. Each load was applied with the knee at full extension and at 30, 60, 90, and 120 degrees of flexion. Without muscle loads, in situ forces in the posterior cruciate ligament were small, ranging from 6+/-5 N at 30 degrees of flexion to 15+/-3 N at 90 degrees. Under an isolated hamstrings load, the in situ force in the posterior cruciate ligament increased significantly throughout all angles of knee flexion, from 13+/-6 N at full extension to 86+/-19 N at 90 degrees. A posterior tibial translation ranging from 1.3+/-0.6 to 2.5+/-0.5 mm was also observed from full extension to 30 degrees of flexion under the hamstrings load. With a combined hamstrings and quadriceps load, tibial translation was 2.2+/-0.7 mm posteriorly at 120 degrees of flexion ut was as high as 4.6+/-1.7 mm anteriorly at 30 degrees. The in situ force in the posterior cruciate ligament decreased significantly under this loading condition compared with under an isolated hamstrings load, ranging from 6+/-7 to 58+/-13 N from 30 to 120 degrees of flexion. With an isolated quadriceps load of 200 N, the in situ forces in the posterior cruciate ligament ranged from 4+/-3 N at 60 degrees of flexion to 34+/-12 N at 120 degrees. Our findings support the notion that, compared with an isolated hamstrings load, combined hamstrings and quadriceps loads significantly reduce the in situ force in the posterior cruciate ligament. These data are in direct contrast to those for the anterior cruciate ligament. Furthermore, we have demonstrated that the effects of muscle loads depend significantly on the angle of knee flexion.

Aged↗

In situ force distribution in the glenohumeral joint capsule during anterior-posterior loading.

Our objective was to examine the function of the glenohumeral capsule and ligaments during application of an anterior-posterior load by directly measuring the in situ force distribution in these structures as well as the compliance of the joint. We hypothesized that interaction between different regions of the capsule due to its continuous nature results in a complex force distribution throughout the glenohumeral joint capsule. A robotic/universal force-moment sensor testing system was utilized to determine the force distribution in the glenohumeral capsule and ligaments of intact shoulder specimens and the joint kinematics resulting from the application of external loads at four abduction angles. Our results suggest that the glenohumeral capsule carries no force when the humeral head is centered in the glenoid with the humerus in anatomic rotation. However, once an anterior-posterior load is applied to the joint, the glenohumeral ligaments carry force (during anterior loading, the superior glenohumeral-coracohumeral ligaments carried 26+/-16 N at 0 degrees and the anterior band of the inferior glenohumeral ligament carried 30+/-21 N at 90 degrees). Therefore, the patient's ability to use the arm with the humerus in anatomic rotation should not be limited following repair procedures for shoulder instability because the repaired capsuloligamentous structures should not carry force during this motion. Separation of the capsule into its components revealed that forces are being transmitted between each region and that the glenohumeral ligaments do not act as traditional ligaments that carry a pure tensile force along their length. The interrelationship of the glenohumeral ligaments forms the biomechanical basis for the capsular shift procedure. The compliance of the joint under our loading conditions indicates that the passive properties of the capsule provide little resistance to motion of the humerus during 10 mm of anterior or posterior translation with anatomic humeral rotation. Finally, this knowledge also enhances the understanding of arm positioning relative to the portion of the glenohumeral capsule that limits translation during examination under anesthesia.

Aged↗

Chitinase gene expression during mycoparasitic interaction of Trichoderma harzianum with its host.

For monitoring chitinase expression during mycoparasitism of Trichoderma harzianum in situ, we constructed strains containing fusions of green fluorescent protein (GFP) to the 5'-regulatory sequences of the T. harzianum nag1 (N-acetyl-beta-d-glucosaminidase-encoding) and ech42 (42-kDa endochitinase-encoding) genes. Confronting these strains with Rhizoctonia solani led to induction of gene expression before (ech42) or after (nag1) physical contact. A 12-kDa cut-off membrane separating the two fungi abolished ech42 expression, indicating that macromolecules are involved in its precontact activation. No ech42 expression was triggered by culture filtrates of R. solani or by placing T. harzianum onto plates previously colonized by R. solani. Instead, high expression occurred upon incubation of T. harzianum with the supernatant of R. solani cell walls digested with culture filtrates or purified endochitinase 42 (CHIT42, encoded by ech42) from T. harzianum. The chitinase inhibitor allosamidin blocked ech42 expression and reduced inhibition of R. solani growth during confrontation. The results indicate that ech42 is expressed before contact of T. harzianum with R. solani and its induction is triggered by soluble chitooligosaccharides produced by constitutive activity of CHIT42 and/or other chitinolytic enzymes.

Acetylglucosaminidase↗

Relative contribution of the ACL, MCL, and bony contact to the anterior stability of the knee.

Ligaments and other soft tissues, as well as bony contact, all contribute to anterior stability of the knee joint. This study was designed to measure the in situ force in the medial collateral ligament (MCL), anterior cruciate ligament (ACL), posterolateral structures (PLS), and posterior cruciate ligament (PCL) in response to 110 N anterior tibial loading. The changes in knee kinematics associated with ACL deficiency and combined MCL+ACL deficiency were also evaluated. Utilizing a robotic/universal force-moment sensor system, ten human cadaveric knee joints were tested between 0 degrees and 90 degrees of knee flexion. This unique testing system is designed to determine the in situ forces in structures of interest without making mechanical contact with the tissue. More importantly, data for individual structures can be obtained from the same knee specimen since the robotic manipulator can reproduce the motion of the intact knee. The in situ forces in the ACL under anterior tibial loading to 110 N were highest at 15 degrees flexion, 103 +/- 14 N (mean +/- SD), decreasing to 59.2 +/- 30 N at 90 degrees flexion. For the MCL, these forces were 8.0 +/- 3.5 N and 38.1 +/- 25 N, respectively. Forces due to bony contact were as high as 34.1 +/- 23 N at 30 degrees flexion, while those in the PLS were relatively small at all flexion angles. Combined MCL+ACL deficiency was found to significantly increase anterior tibial translation relative to the ACL-deficient knee only above 60 degrees of knee flexion. These findings confirm the hypothesis that there is significant load sharing between various ligaments and bony contact during anterior tibial loading of the knee. For this reason, the MCL and osteochondral surfaces may also be at significant risk during ACL injury.

Aged↗

Hamstring graft motion in the femoral bone tunnel when using titanium button/polyester tape fixation.

The objective of this study was to determine the relative motion of a quadruple hamstring graft within the femoral bone tunnel (graft-tunnel motion) under tensile loading. Six graft constructs were prepared from the semitendinosus and gracilis tendons of human cadavers and were fixed with a titanium button and polyester tape within a bone tunnel in a cadaveric femur. Three different lengths of polyester tape (15, 25, and 35 mm loops) were evaluated. The femur was held stationary and uniaxial tensile loads were applied to the distal end of the graft using a materials testing machine. Each construct was subjected to loading for ten cycles with upper limits of 50 N, 100 N, 200 N and 300 N. Graft-tunnel motion was then determined using the distances between reflective tape markers placed on the hamstring graft and at the entrance to the femoral bone tunnel, which were tracked with a high-resolution video system. Graft-tunnel motion was found to range from 0.7 +/- 0.2 mm to 3.3 +/- 0.2 mm, and significant increases in graft-tunnel motion were observed with increasing tensile loads (P < 0.05). Shorter tape length (15 mm) resulted in significantly less motion when compared to longer tape length (35 mm) (P < 0.05). We conclude that graft-tunnel motion is significant and should be considered when using this fixation technique. Early stress on the graft, as seen in postoperative rehabilitation exercises and athletic activities, may cause large graft-tunnel motion before graft incorporation is complete. A shorter distance between the tendon tissue and the titanium button is recommended to minimize the amount of graft-tunnel motion. Alternative fixation materials to polyester tape, or different fixation techniques, need to be developed such that graft-tunnel motion can be reduced. Further studies are needed to evaluate the effect of graft-tunnel motion on graft incorporation in the bone tunnel.

Biomechanical Phenomena↗

The importance of quadriceps and hamstring muscle loading on knee kinematics and in-situ forces in the ACL.

This study investigated the effect of hamstring co-contraction with quadriceps on the kinematics of the human knee joint and the in-situ forces in the anterior cruciate ligament (ACL) during a simulated isometric extension motion of the knee. Cadaveric human knee specimens (n = 10) were tested using the robotic universal force moment sensor (UFS) system and measurements of knee kinematics and in-situ forces in the ACL were based on reference positions on the path of passive flexion/extension motion of the knee. With an isolated 200 N quadriceps load, the knee underwent anterior and lateral tibial translation as well as internal tibial rotation with respect to the femur. Both translation and rotation increased when the knee was flexed from full extension to 30 of flexion; with further flexion, these motion decreased. The addition of 80 N antagonistic hamstrings load significantly reduced both anterior and lateral tibial translation as well as internal tibial rotation at knee flexion angles tested except at full extension. At 30 of flexion, the anterior tibial translation, lateral tibial translation, and internal tibial rotation were significantly reduced by 18, 46, and 30%, respectively (p<0.05). The in-situ forces in the ACL under the quadriceps load were found to increase from 27.8+/-9.3 N at full extension to a maximum of 44.9+/-13.8 N at 15 of flexion and then decrease to 10 N beyond 60 of flexion. The in-situ force at 15 was significantly higher than that at other flexion angles (p<0.05). The addition of the hamstring load of 80 N significantly reduced the in-situ forces in the ACL at 15, 30 and 60 of flexion by 30, 43, and 44%, respectively (p<0.05). These data demonstrate that maximum knee motion may not necessarily correspond to the highest in-situ forces in the ACL. The data also suggest that hamstring co-contraction with quadriceps is effective in reducing excessive forces in the ACL particularly between 15 and 60 of knee flexion.

Adult↗

A new methodology to measure load transfer through the forearm using multiple universal force sensors.

Previous approaches to measuring forces in the forearm have made the assumption that forces acting in the radius and ulna are uniaxial near the wrist and elbow. To accurately describe forces in the forearm and the forces in the interosseous ligament, we have developed a new methodology to quantitatively determine the 3-D force vectors acting in forearm structures when a compressive load is applied to the hand. A materials testing machine equipped with a six degree-of-freedom universal force-moment sensor (UFS) was employed to apply a uniaxial compressive force to cadaveric forearms gripped at the hand and humerus. Miniature UFSs were implanted into the distal radius and proximal ulna to measure force vectors there. A 3-D digitizing device was used to measure transformations between UFS coordinate systems, utilized for calculating the force vectors in the distal ulna, proximal radius, and the interosseous ligament (IOL). This method was found to be repeatable to within 3 N, and accurate to within 2 N for force magnitudes. Computer models of the forearm, generated from CT scans, were used to visualize the force vectors in 3-D. Application of this methodology to eight forearm specimens showed that the radius carries most of the load at the wrist while force in the IOL relieves load acting in the radius at the mid-forearm. For a 136 N applied hand force, the force in the IOL was 36 + 21 N. Advantages of this methodology include the determination of 3-D force vectors, especially those in the IOL, as well as computer generated 3-D visualization of results.

Biomechanical Phenomena↗

Quantitative analysis of human cruciate ligament insertions.

The objective of this study was to provide quantitative data on the insertion sites of the cruciate ligaments. In the first part of the study, we determined the shapes and sizes of the insertions of the anterior and posterior cruciate ligaments (ACL and PCL), and further compared these data with the midsubstance cross-sectional areas of the ligaments. The cross-sectional area of the ACL and PCL midsubstance of 5 human knees was measured using a laser micrometer system. The insertion sites of each ligament were then digitized and the 2-dimensional insertion site areas were determined. Relative to the ligament midsubstance, the PCL tibial and femoral insertions were approximately 3 times larger, whereas those of the ACL were over 3.5 times larger. In the second part of the study, the ACLs and PCLs of 10 knees were each divided into their 2 components and the areas of each insertion were determined. Each component was approximately 50% of the total ligament insertion area and no significant difference between the 2 could be shown.

Aged↗

Use of robotic technology for diathrodial joint research.

Knowledge of diarthrodial joint mechanics and specific function of the ligaments are needed in order to understand injury mechanisms, improve surgical procedures and design better post-surgical rehabilitation protocols. To facilitate these needs, a robotic/universal force-moment sensor (UFS) testing system was developed to measure joint kinematics in multiple degree-of-freedom and the in situ forces in the ligaments. When operated in the position control mode, the testing system applies a known load to the intact joint while the motion and force data are recorded. After transection of a ligament, the recorded motion for the intact joint is repeated and new force and moment data is recorded by the UFS. Since the robot reproduces the identical initial position as well as path of joint motion before and after a ligament is transected, the in situ force in the ligament is the difference between the two sets of force and moment data. In force control mode, a known force is applied to the intact knee while the kinematics are recorded. After ligament transection, the same force is applied while the changes in kinematics are again recorded. Testing in this mode is similar to a clinical examination that diagnoses ligament injury. To date, this testing system has been used for experimental studies that examine the anterior cruciate ligament & posterior cruciate ligament of the knee and ligaments of the shoulder. A three-dimensional finite element model has also been constructed based on CT/MRI scans of a knee specimen and validated using data obtained with the testing system. Once in vivo kinematics (such as during gait analysis or throwing activities) are available, the robotic/UFS testing system can be programmed to reproduce these joint kinematics on young human cadaveric specimens in order to generate a database for in situ forces in the ligaments, or Ligament replacement grafts. With appropriate computational models, the stresses and strains in these tissues in vivo can also be determined. Potential applications of this combined approach include pre-operative surgical planning, improvement of surgical procedures as well as development of appropriate post-operative rehabilitation protocols.

Biomechanical Phenomena↗

Effects of tenorraphy on the gliding function and tensile properties of partially lacerated canine digital flexor tendons.

Management of a partially lacerated digital flexor tendon within zone II remains controversial. To address this issue, we undertook an evaluation of the impact of tenorrhaphy on the gliding function and tensile properties of canine flexor tendons with lacerations involving either 30% or 70% of their cross-sectional area. Assessment of tendon excursion and joint rotation after 6 weeks of postoperative controlled passive mobilization failed to reveal any statistically significant benefit from tenorrhaphy on the gliding function. In fact, we demonstrated a significant negative effect of repair on tendons with 30% lacerations. Moreover, no significant differences between the structural properties or integrity of the repaired and nonrepaired tendons could be demonstrated. Thus, in light of the inherent tensile properties in these partially lacerated tendons, our data suggest that digital function of partially lacerated tendons of up to 70% of the cross-sectional area may be preserved without primary repair. However, additional work is needed to more definitively address this issue in a clinical context.

Animals↗

Injury and reconstruction of the anterior cruciate ligament and knee osteoarthritis.

OBJECTIVE: The objective of this study was to study injury and reconstruction of the anterior cruciate ligament (ACL) and their effects on knee osteoarthritis. DESIGN: This manuscript discusses the function of knee ligaments, including the basic mechanical properties, the structural properties of their respective bone-ligament-bone complexes, as well as their time- and history-dependent viscoelastic characteristics. The in-situ forces in the ACL and its replacement grafts and knee kinematics before and after ACL reconstruction are also examined. RESULTS: A robotic/universal force-moment sensor (UFS) testing system has been developed which offers a unique method in determining the multiple-degree of freedom knee kinematics and in-situ forces in human cadaveric knees. Under a 110 N anterior tibial load we found at flexion angles of 15 degrees or lower, there was a significantly larger in-situ force in the PL bundle (approximately 75 N) of the ACL as compared to the AM bundle (approximately 35 N)(P < 0.05). We also found that a quadruple semitendinosus and gracilis tendon ACL graft may be better at fully restoring in-situ forces for the whole range of knee flexion when compared to a bone-patellar tendon-bone ACL graft. CONCLUSIONS: The robotic/UFS testing system allows us to determine knee kinematics and the in-situ forces in cadaveric knees in a non-invasive, non-contact manner. Additionally, the ability to reproduce kinematics during testing allows us to evaluate ACL and ACL graft function under external and simulated muscle loading conditions. Finally, we can also examine many of the variables of ACL reconstructions that affect knee kinematics and graft forces including graft tensioning, graft type, graft placement and tibial positioning during graft fixation.

Anterior Cruciate Ligament↗

Comparison of long-term survival of cytomegalovirus promotre versus Rous Sarcoma virus promoter-driven thymidine kinase gene therapy in nude mice bearing human ovarian cancer.

The cytomegalovirus (CMV) promoter is considered one of the strongest positive regulators leading to expression of higher levels of the thymidine kinase (TK) enzyme than the Rous Sarcoma virus (RSV) promoter in vitro and in vivo. Cell killing efficacy of adenovirus-mediated CMV promoter-driven herpes simplex virus (HSV) TK gene therapy has been found to be 2 to 10 times more effective than RSV driven HSV-TK gene therapy in vitro. In this study the impact of CMV- versus RSV-driven HSV-TK gene therapy on long-term survival of nude mice bearing human ovarian cancer has been evaluated using a prospective randomized experimental design. The experiment was designed to show significance of survival differences from a 50% increase of survived days at a p-value of 0.05 with a power of 80%. All treatment groups showed an increase in median survival compared with control groups. Treatment benefit was ADV/CMV-TK vector dose dependent. At a given viral dose, no significant prolongation of survival was observed comparing CMV- and RSV-driven ADV-TK indicating that simply increasing cell killing efficacy in vitro above a minimal threshold level using a stronger promoter may not lead to prolongation of survival in the HSV-TK/GCV system.

Adenoviridae↗

Tissue engineering of ligament and tendon healing.

Ligaments and tendons are bands of dense connective tissue that mediate normal joint movement and stability. Injury to these structures may result in significant joint dysfunction because they either heal by production of inferior matrix or do not heal at all. The process of ligament and tendon healing is complex and the roles of cellular and biochemical mediators continue to be elucidated. The expression of growth factors and growth factor receptors is modulated after injury, and cells from healing tissues are responsive to growth factors. Tissue engineering offers the potential to improve the quality of ligaments and tendons during the healing process. The concept is based on the manipulation of cellular and biochemical mediators to affect protein synthesis and improve tissue remodeling. Recently, novel techniques such as application of growth factors, gene transfer techniques, and cell therapy have shown promise and may become effective biologic therapies in the future. Many groups have been successful in introducing marker and therapeutic genes into ligaments and tendons. Cell therapy involves the introduction of mesenchymal progenitor cells as a pluripotent cell source into the healing environment. The combination of cell therapy with growth factor application via gene transfer offers new avenues to improve ligament and tendon healing.

Animals↗

Limitations of adenovirus-mediated interleukin-2 gene therapy for oral cancer.

OBJECTIVE/HYPOTHESIS: Adenoviral interleukin-2 (AdV-IL-2) gene therapy has previously not proven effective in treating established murine oral cancer. We hypothesize that the intratumoral level of IL-2 expression is a major limiting factor in treatment outcome. METHODS: A microscopic disease and established oral cancer murine model was used to test this hypothesis. IL-2 gene transfer was performed with a recombinant adenovirus vector. RESULTS: Tumor cells were transduced in vitro with AdV-IL-2 and subsequently implanted into the floor of the mouth in C3H/HeJ mice. IL-2 expression in vitro ranged from 990 to 1,050 pg/10(6) tumor cells. This microscopic disease treatment resulted in either complete tumor regression or a dramatic decrease in tumor progression. Cytolytic T-cell (CTL) assays demonstrated a predominance of CD8-specific, T-cell-mediated tumor killing. Reducing IL-2 expression by half with a mixture of 1:1 transduced to nontransduced tumor cells eliminated the antitumor effect and decreased the CTL response. These findings support the presence of a critical "threshold" of IL-2 expression. Adenovirus repurification and amplification allowed isolation of a twofold-higher-titer AdV-IL-2 vector. Treatment of established tumors with the higher-titer AdV-IL-2 at a new maximal dose of 1.4 x 10(9) plaque-forming units (pfu) increased in vivo IL-2 expression to 1,127 pg/10(6) cells and generated a significant antitumor response. Complete regression of established tumors, however, could not be achieved, and we noted a decrease in IL-2 expression well below the threshold at 1 week after treatment. Upon repeat maximal AdV-IL-2 injection in vivo, a greater antitumor effect and increased CTL response was seen, but also, 28% of the animals died of IL-2 toxicity. CONCLUSION: Although limited by expression and toxicity as a single-treatment strategy for established tumors, AdV-IL-2 gene therapy should be considered a potential component of combination therapy strategies.

Adenoviridae↗

An analytical approach to determine the in situ forces in the glenohumeral ligaments.

The purpose of this study was to use an analytical approach to determine the forces in the glenohumeral ligaments during joint motion. Predictions from the analytical approach were validated by comparing them to experimental data. Using a geometric model, the lengths of the four glenohumeral ligaments were determined during anterior-posterior loading simulations and forward flexion-extension. The corresponding force in each structure was subsequently calculated based on length data via load-elongation curves obtained experimentally. During the anterior loading simulation at 0 deg of abduction, the superior glenohumeral ligament carried up to 71 N at the maximally translated position. At 90 deg of abduction, the anterior band of the inferior glenohumeral ligament had the highest force of 45 N during anterior loading. These results correlated well with those found in previous experimental studies. We believe that this validated analytical approach can be used to predict the forces in the glenohumeral ligaments during more complex joint motion as well as assist surgeons during shoulder repair procedures.

Aged↗

A validated three-dimensional computational model of a human knee joint.

This paper presents a three-dimensional finite element tibio-femoral joint model of a human knee that was validated using experimental data. The geometry of the joint model was obtained from magnetic resonance (MR) images of a cadaveric knee specimen. The same specimen was biomechanically tested using a robotic/universal force-moment sensor (UFS) system and knee kinematic data under anterior-posterior tibial loads (up to 100 N) were obtained. In the finite element model (FEM), cartilage was modeled as an elastic material, ligaments were represented as nonlinear elastic springs, and menisci were simulated by equivalent-resistance springs. Reference lengths (zero-load lengths) of the ligaments and stiffness of the meniscus springs were estimated using an optimization procedure that involved the minimization of the differences between the kinematics predicted by the model and those obtained experimentally. The joint kinematics and in-situ forces in the ligaments in response to axial tibial moments of up to 10 Nm were calculated using the model and were compared with published experimental data on knee specimens. It was also demonstrated that the equivalent-resistance springs representing the menisci are important for accurate calculation of knee kinematics. Thus, the methodology developed in this study can be a valuable tool for further analysis of knee joint function and could serve as a step toward the development of more advanced computational knee models.

Aged↗