PubMed Health⌕ Search

Biomedical subjects

S Lévêque-Fort

Publications and source records attributed to S Lévêque-Fort.

5 recordsLinked to original sources

Enhanced fluorescence cell imaging with metal-coated slides.

Fluorescence labeling is the prevailing imaging technique in cell biology research. When they involve statistical investigations on a large number of cells, experimental studies require both low magnification to get a reliable statistical population and high contrast to achieve accurate diagnosis on the nature of the cells' perturbation. Because microscope objectives of low magnification generally yield low collection efficiency, such studies are limited by the fluorescence signal weakness. To overcome this technological bottleneck, we proposed a new method based on metal-coated substrates that enhance the fluorescence process and improve collection efficiency in epifluorescence observation and that can be directly used with a common microscope setup. We developed a model based on the dipole approximation with the aim of simulating the optical behavior of a fluorophore on such a substrate and revealing the different mechanisms responsible for fluorescence enhancement. The presence of a reflective surface modifies both excitation and emission processes and additionally reshapes fluorescence emission lobes. From both theoretical and experimental results, we found the fluorescence signal emitted by a molecular cyanine 3 dye layer to be amplified by a factor approximately 30 when fluorophores are separated by a proper distance from the substrate. We then adapted our model to the case of homogeneously stained micrometer-sized objects and demonstrated mean signal amplification by a factor approximately 4. Finally, we applied our method to fluorescence imaging of dog kidney cells and verified experimentally the simulated results.

Cell Culture Techniques↗

Diode-pumped passively mode-locked Nd:YVO4 laser at 914 nm.

We demonstrate, for the first time, to our knowledge, a diode-pumped passively mode-locked Nd:YVO4 laser, operating on the 4F(3/2)-4I(9/2) transition of the neodymium ion at 914 nm. We obtained 8.8 ps pulses at approximately 914 nm at a repetition rate of 94 MHz, and an averaged output power of 87 mW by using a semiconductor saturable absorber mirror.

Journal Article↗

Fluorescence lifetime imaging with a low-repetition-rate passively mode-locked diode-pumped Nd:YVO4 oscillator.

We report a wide-field fluorescence lifetime imaging microscope based on a low-repetition-rate (3.7-MHz) passively mode-locked diode-pumped laser source. This inexpensive and compact laser source operating in the visible and UV range can excite a wide range of fluorophores of biological interest. We demonstrate that the power of this laser source is highly sufficient for studying biological systems with low quantum yields (autofluorescence of tissues and stained living cells). The maximum measurable lifetime is also strongly increased with this laser source, as fluorescence intensity measurement can occur 250 ns after the excitation pulse.

Cells, Cultured↗

Fluorescence-lifetime imaging with a multifocal two-photon microscope.

Two-photon microscopy is a powerful tool for imaging of cells or tissues. However, it presents the drawback of being a laser-scanning technique that involves a long acquisition time for fluorescence-lifetime imaging. Thus it is commonly limited to intensity images that give only indications of the location of fluorophores but do not identify the physicochemical properties and interactions between cells' components. To protect biological samples from experiments that are too long and to provide a more comprehensive spectroscopic tool we have developed a time-resolved multifocal multiphoton microscope. This setup allows us to speed up the acquisition while retaining the possibility of measuring both intensity and lifetime images of the sample.

Equipment Design↗

Application of the stretched exponential function to fluorescence lifetime imaging.

Conventional analyses of fluorescence lifetime measurements resolve the fluorescence decay profile in terms of discrete exponential components with distinct lifetimes. In complex, heterogeneous biological samples such as tissue, multi-exponential decay functions can appear to provide a better fit to fluorescence decay data than the assumption of a mono-exponential decay, but the assumption of multiple discrete components is essentially arbitrary and is often erroneous. Moreover, interactions, both between fluorophores and with their environment, can result in complex fluorescence decay profiles that represent a continuous distribution of lifetimes. Such continuous distributions have been reported for tryptophan, which is one of the main fluorophores in tissue. This situation is better represented by the stretched-exponential function (StrEF). In this work, we have applied, for the first time to our knowledge, the StrEF to time-domain whole-field fluorescence lifetime imaging (FLIM), yielding both excellent tissue contrast and goodness of fit using data from rat tissue. We note that for many biological samples for which there is no a priori knowledge of multiple discrete exponential fluorescence decay profiles, the StrEF is likely to provide a truer representation of the underlying fluorescence dynamics. Furthermore, fitting to a StrEF significantly decreases the required processing time, compared with a multi-exponential component fit and typically provides improved contrast and signal/noise in the resulting FLIM images. In addition, the stretched-exponential decay model can provide a direct measure of the heterogeneity of the sample, and the resulting heterogeneity map can reveal subtle tissue differences that other models fail to show.

Animals↗