PubMed Health⌕ Search

Biomedical subjects

S Lehner

Publications and source records attributed to S Lehner.

8 recordsLinked to original sources

Comparing biomechanical investigations about different wiring techniques of finger joint arthrodesis.

INTRODUCTION: Multiple operative techniques are currently used for finger arthrodesis in clinical practice. The present study was designed to compare the biomechanical characteristics of typical arthrodesis techniques used in daily practice. MATERIAL AND METHODS: Osteosynthesis techniques comprising wire cerclage, thread cerclage (PDS) or intraosseous wire suture were compared in a biomechanical experiment for resistance against bending loads. The mentioned techniques were applied to artificial specimens with resected articular surfaces or by using the cup-and-cone procedure. In this process, the specimens were tested using various Kirschner-wire insertion angles as well as different arthrodesis angles (20 degrees vs 40 degrees) in a 4-point bending test with each group consisting of 6 specimens of acrylic glass. The forces prevalent in the joint space were determined by prescale pressure measurement foils. RESULTS: Wire tension banding resisted significantly higher bending moments than arthrodeses with thread tension bands (p < 0.05). All set-ups with tension banding techniques tolerated significantly higher loads than the intraosseous wire sutures without additional K-wires (p < 0.05), which showed unfavorable dislocation of contact areas resulting in instability even under relatively minor bending loads. Using the cup-and-cone technique, a geometrically larger contact area could be achieved between two unloaded fragments, but this technique showed no advantages in the opposing bending moments compared with the conventional resection method. In both techniques, a dislocation of contact surfaces towards the palmar direction could be observed with increasing bending moment. While the use of thread tension band fixation reduces the risk of plastic deformation of both osteosynthetic material and bone stock, the problem of resorption rate has to be taken into account when choosing the material for the thread. CONCLUSIONS: Considering pressure distribution and stability with and without bending loads, it is not the most rigid osteosynthesis technique which should be viewed as the ideal treatment. In contrast, it is more important to consider the various and most likely conditions to be expected in daily life after arthrodesis and therefore to chose the type of technique distributing pressure as regularly as possible.

Arthrodesis↗

BISS: concept and biomechanical investigations of a new screw system for electromagnetically induced internal osteostimulation.

INTRODUCTION: The aim of an intraosseous application of electromagnetic alternating fields is to speed up both the regeneration of osteonecroses and bone regeneration. In clinical studies, the efficiency of the technique could be successfully proven by using a transducer coil. The advantage of the traditional technique was the variety of its applications in connection with various osteosynthesis systems; the disadvantage was a possible failure of the contacting leads and the resulting functional breakdown. MATERIALS AND METHODS: A newly developed BISS screw (bipolar induction screw system) with integrated coil and electrodes was compared to a standard cannulated screw used in the traditional technique. The strength of BISS screws ( n=6) and of cannulated screws ( n=6) was evaluated in comparative biomechanical tests. Examinations consisted of torsional and static and dynamic cantilever tests. All screws were made of the same material (TiAl(6)V(4)) and had identical outer dimensions. RESULTS: No significantly lower strengths could be observed when we compared BISS screws with cannulated screws. The BISS screws even showed significantly higher mechanical values due to a reinforcing effect by the attached electrode. CONCLUSION: In the modified concept of the new BISS screw, both coil and electrodes are housed in only one cannulated screw. No negative effects concerning mechanical strength and durability were associated with the new screw concept. This provides for a simpler implantation and makes removal easier, while the risk of a cable tear is avoided.

Alloys↗

[New compounds for improving wear behavior of a tumor knee endoprosthesis].

Wear of the central bushing made of ultra-high molecular weight polyethylene (PE-UHMW) of the hinged knee endoprosthesis of a tumour-resection system is the leading reason for revision. The aim of the study was to optimize the wear characteristics of the endoprosthesis on the basis of the tribological properties of new materials and an additional finite element (FE) calculation taking account of the given design. In screening tests the reference combination of PE-UHMW bushing and CoCr axis--used in the clinical setting--was first tested. The PE-UHMW bushing was then replaced by one made of each of the materials reinforced high-density polyethylene (PE-HD) and carbon fibre-reinforced epoxy resin (CFRP). In addition, a new material combination with an alumina ceramic bushing and a CFRP axis was investigated. In comparison with the reference combination PE-UHMW/metal, the combination of ceramic bushing and CFRP axis showed less wear. However, with the particular design of the prosthesis studied here, high mechanical loading applied experimentally resulted in mechanical failure. FE calculations confirmed these experimental results. Improvement of the wear characteristics of this specific implant caused therefore be achieved only by optimizing the bearing design.

Biomechanical Phenomena↗

[Enlarged spectrum of tick transmitted spirochaetoses].

After the successful identification of Borrelia burgdorferi as the cause of Lyme disease, a new tick-borne infection occurring in the United States, almost identical spirochaetes have been isolated from the tick Ixodes ricinus in Europe. As a result, the spirochaetal aetiology of skin diseases, which had long been recognized as tick-borne infections, namely erythema chronicum migrans with its neurological complications of the tick-borne meningopolyneuritis of Garin-Bujadoux-Bannwarth, acrodermatitis chronica atrophicans and lymphadenosis cutis benigna, could be confirmed by means of microbiological, histological and serological methods. On the basis of case histories it had already been assumed for some time that anetodermia maculosa and the localised sclerodermas might also be caused by a tick-borne agent. The results of serological investigations have now strengthened this assumption, although microbiological confirmation is still lacking.

Acrodermatitis↗