PubMed Health⌕ Search

Biomedical subjects

S Leide-Svegborn

Publications and source records attributed to S Leide-Svegborn.

6 recordsLinked to original sources

Biokinetics of iodide in man: refinement of current ICRP dosimetry models.

A compartmental model describing the distribution and retention of radioactive iodide in thyroid and other organs is presented. The model is developed from published ICRP models. It is designed primarily for radiation dosimetry of iodine radionuclides used in nuclear medicine, but may also be useful for occupational radiation protection. In the proposed model, the distribution of iodide to the thyroid is assumed to be more rapid than in earlier models. Uptakes in stomach wall and salivary glands are considered, and the absorbed doses to these organs calculated. The partitioning of iodide between stomach wall and content is also discussed. Recirculation of organic iodine is also taken into account. Age-dependent half-times for iodide in the thyroid, as well as for organically-bound iodine are presented. The proposed model is applicable for dose estimations with different uptakes in the thyroid as well as for the situation when the thyroid is blocked, completely or incompletely.

Adolescent↗

A generic model for 11C labelled radiopharmaceuticals for imaging receptors in the human brain.

A large number of radiopharmaceuticals labelled with 11C (half-time 0.340 h) are being developed for positron emission tomographic studies of different types of receptor in the human brain. For most of these agents, the available biokinetic data are insufficient to construct realistic compound-specific biokinetic models for calculating the internal radiation dose delivered to persons undergoing investigation. A generic model for brain receptor substances that predicts the internal dose with sufficient accuracy for general radiation protection purposes has, therefore, been developed. Biokinetic data for 13 11C-radiopharmaceuticals used clinically for imaging different brain receptors indicate that, despite differences in chemical structure, their uptake and retention in the human brain and other tissues are broadly similar. The proposed model assumes instantaneous deposition of 5% of the injected radioactivity in the brain, with the remaining radioactivity being rapidly and uniformly distributed throughout all other tissues. Elimination from all tissues is assumed to occur with a half-time of 2 h. It is further assumed that 75% of the injected 11C is excreted in the urine, and 25% via the gall bladder, with a half-time of 2 h. This model yields an effective dose of 4.5 x 10(-3) mSv MBq(-1), with doses of 3.2 x 10(-2), 1.7 x 10(-2), 8.7 x 10(-3), 5.2 x 10(-3), and 3.8 x 10(-3) mGy MBq(-1) to the urinary bladder, gall bladder, kidneys, brain and ovaries, respectively. These doses are well within the range of those reported using compound-specific models for the radiopharmaceutals studied.

Brain↗

No radiation protection reasons for restrictions on 14C urea breath tests in children.

Traditional (14)C urea breath tests are normally not used for younger children because the radiation exposure is unknown. High sensitivity accelerator mass spectrometry and an ultra-low amount (440 Bq) of (14)C urea were therefore used both to diagnose Helicobacter pylori (HP) infection in seven children, aged 3-6 years, and to make radiation dose estimates. The activity used was 125 times lower than the amount normally used for older children and 250 times lower than that used for adults. Results were compared with previously reported biokinetic and dosimetric data for adults and older children aged 7-14 years. (14)C activity concentrations in urine and exhaled air per unit administered activity for younger children (3-6 years) correspond well with those for older children (7-14 years). For a child aged 3-6 years who is HP negative, the urinary bladder wall receives the highest absorbed dose, 0.3 mGy MBq(-1). The effective dose is 0.1 mSv MBq(-1) for the 3-year-old child and 0.07 mSv MBq(-1) for the 6-year-old child. For two children, the 10 min and 20 min post-(14)C administration samples of exhaled air showed a significantly higher amount of (14)C activity than for the rest of the children, that is 6% and 19% of administered activity exhaled per hour compared with 0.3-0.9% (mean 0.5%) of administered activity exhaled per hour indicating that these two children that is were HP positive. For a 3-year-old HP positive child, absorbed dose to the urinary bladder wall was 0.3 mGy MBq(-1) and effective dose per unit of administered activity was 0.4 mSv MBq(-1). Using 55 kBq, which is a normal amount for older children when liquid scintillation counters are used for measurement, the effective dose will be approximately 6 micro Sv to a 3-year-old HP negative child and 20 microSv to a HP positive child. Thus there is no reason for restrictions on performing a normal (14)C urea breath test, even on young children.

Adolescent↗

Biokinetics and radiation doses for carbon-14 urea in adults and children undergoing the Helicobacter pylori breath test.

The long-term biokinetics and dosimetry of carbon-14 were studied in nine adults and eight children undergoing carbon-14 urea breath test for Helicobacter pylori (HP) infection. The elimination of 14C via exhaled air and urine was measured with the liquid scintillation counting technique and with accelerator mass spectrometry. After the subjects had been given 110 kBq 14C-urea (children: 55 kBq) orally, samples of exhaled air were taken up to 180 days after administration and samples of urine were collected up to 40 days. Sixteen of the subjects were found to be HP-negative. In these subjects a total of 91.1%+/-3.9% (mean of adults and children +/- standard error of the mean) of the administered 14C activity was recovered. The majority of the administered activity, 88.3%+/-6.2% in adults and 87.7%+/-5.0% in children, was excreted via the urine within 72 h after administration. A smaller fraction was exhaled. In adults 4.6%+/-0.6% of the activity was exhaled within 20 days and in children 2.6%+/-0.3%. Uncertainties in the biokinetic results are mainly due to assumptions concerning endogenous CO2 production and urinary excretion rate and are estimated to be less than 30%. The absorbed dose to various organs and the effective dose were calculated using the ICRP model for urea and CO2. The urinary bladder received the highest absorbed dose: in adults, 0.15+/-0.01 mGy/MBq and in children of various ages (7-14 years), 0.14-0.36 mGy/MBq. The findings indicate that an investigation with 14C-urea gives an effective dose to adults of 2.1+/-0.1 microSv (for 110 kBq) and to children of 0.9-2.5 microSv (for 55 kBq). From a radiation protection point of view, there is thus no reason for restrictions on even repeated screening investigations with 14C-urea in whole families, including children.

Adolescent↗

Application of accelerator mass spectrometry (AMS) for high-sensitivity measurements of 14CO2 in long-term studies of fat metabolism.

Long-term measurements of 14C in CO2 expired after ingestion of 14C-labelled triolein were performed using accelerator mass spectrometry (AMS). About 30% of a given amount of 14C-labelled triolein was catabolized rapidly, while the remaining 70% had a very slow turnover. The study shows the potential of the AMS technique for the study of the long-term biokinetics of 14C-labelled pharmaceuticals. The AMS technique allows the administered activity to be reduced by several orders of magnitude without compromising the study. It may also allow studies of rare drug metabolites.

Adult↗

Effective dose from radiopharmaceuticals.

The effective dose, as defined by the International Commission on Radiological Protection (ICRP 1991), provides a possibility of expressing the radiation risk to patients undergoing different radiodiagnostic procedures by means of a single figure. This has been obtained by introducing organ or tissue weighting factors reflecting the radiation sensitivity of the organs. Such weighting factors were first published by the ICRP in publication 26 (1977), and have now been revised in publication 60 (1991). The effective dose for almost all radiopharmaceuticals in clinical use has been recalculated using the new weighting factors from ICRP 60 (1991) and compared with results from former calculations. A slight decrease in the numerical value for the effective dose has been observed, on average 11%. However, this does not correspond to a decrease in the estimated risk from the irradiation, since this has been re-evaluated and found to be higher than earlier believed (NAS 1990; ICRP 1991).

Humans↗