PubMed Health⌕ Search

Biomedical subjects

S Lowes

Publications and source records attributed to S Lowes.

7 recordsLinked to original sources

Genomic variation in Streptococcus mutans: deletions affecting the multiple pathways of beta-glucoside metabolism.

The genome of Streptococcus mutans UA159 contains two phospho-beta-glucosidase genes, bglA and celA, which occur in operon-like arrangements along with genes for components of phosphotransferase transport systems and a third phospho-beta-glucosidase encoded by the arb gene, which does not have its own associated transport system but relies on uptake by the bgl or cel systems. Targeted inactivation of each of the phospho-beta-glucosidase genes revealed that bglA is involved in aesculin hydrolysis, celA is essential for utilisation of cellobiose, amygdalin, gentobiose and salicin, and arb is required for utilisation of arbutin. Inactivation of genes for the phosphotransferase systems revealed an overlap of specificity for transport of beta-glucosides and also indicated that further, unidentified transport systems exist. The cel and arb genes are subject to catabolite repression by glucose, but the regM gene is not essential for catabolite repression. Screening a collection of isolates of S. mutans revealed strains with deletions affecting the msm, bgl and/or cel operons. The phenotypes of these strains could largely be explained on the basis of the results obtained from the knockout mutants of S. mutans UA159 but also indicated the existence of other pathways apparently absent from UA159. The extensive genetic and phenotypic variation found in beta-glucoside metabolism indicates that there may be extensive heterogeneity in the species.

Amygdalin↗

A four-column parallel chromatography system for isocratic or gradient LC/MS analyses.

A novel approach to parallel liquid chromatography/ tandem mass spectrometry (LC/MS/MS) analyses for pharmacokinetic assays and for similar quantitative applications is presented. Modest modifications render a conventional LC/MS system capable of analyzing samples in parallel. These modifications involve the simple incorporation of three valves and four LC columns into a conventional system composed of one binary LC pumping system, one autosampler, and one mass spectrometer. An increase in sample throughput is achieved by staggering injections onto the four columns, allowing the mass spectrometer to continuously analyze the chromatographic window of interest Using this approach, the optimized run time is slightly greater than the sum of the widths of the desired peaks. This parallel chromatography unit can operate under both gradient and isocratic LC conditions. To demonstrate the utility of the system, atorvastatin, five of its metabolites, and their deuterated internal standards (IS) were analyzed using gradient elution chromatography conditions. The results from a prestudy assay evaluation (PSAE) tray of standards and quality control (QC) samples from extracted spiked human plasma are presented. The relative standard deviation and the accuracy of the QC samples did not exceed 8.1% and 9.6%, respectively, which is well within the acceptance criteria of the pharmaceutical industry. For this particular analysis, the parallel chromatography system decreased the overall run time from 4.5 to 1.65 min and, therefore, increased the overall throughput by a factor of 2.7 in comparison to a conventional LC/MS/MS analytical method.

Journal Article↗

Human intestinal cell monolayers are preferentially sensitive to disruption of barrier function from basolateral exposure to cholic acid: correlation with membrane transport and transepithelial secretion.

Unconjugated bile acids such as cholic acid cause diarrhoea, mucosal irritation and toxicity. We sought to define the mechanism of cholate permeation across intestinal mucosal cells to understand how cellular exposure and accumulation are deleterious to mucosal function. Human intestinal Caco-2 and T84 cell monolayers were prepared by high-density seeding and cultured for >14 days on permeable culture supports. Cholate transport and cellular accumulation were determined using [3H]cholic acid. Epithelial barrier function was assessed by measuring transepithelial electrical resistance (Rt) and [14C]mannitol fluxes. Exposure of Caco-2 epithelia to serosal cholate caused a dose- and time-dependent disruption of barrier function. Apical exposure was without disruptive effect. Similar responses were observed for T84 epithelia. Cholate was preferentially accumulated across the basolateral surfaces in both Caco-2 and T84 cells, but was subject to active transepithelial secretion in Caco-2 monolayers only. Net secretion was substantially reduced by ATP depletion, showed saturation kinetics, and was subject to competitive inhibition by other bile acids. Cholate secretion was also sensitive to inhibition by the leukotriene antagonist MK-571 but not by digoxin, suggesting that MRP2, not MDR1, was responsible. RT-PCR and Western blotting confirmed MRP2 expression in Caco-2 epithelia but indicated its apparent absence from T84 cells.

Absorption↗

Quantitative liquid chromatographic-tandem mass spectrometric determination of reserpine in FVB/N mouse plasma using a "chelating" agent (disodium EDTA) for releasing protein-bound analytes during 96-well liquid-liquid extraction.

A sensitive, specific, accurate and reproducible analytical method employing a divalent cation chelating agent (disodium EDTA) for sample treatment was developed to quantitate reserpine in FVB/N mouse plasma. Samples pretreated with 40 microl of 2% disodium EDTA in water were extracted by a semi-automated 96-well liquid-liquid extraction (LLE) procedure to isolate reserpine and a structural analog internal standard (I.S.), rescinnamine, from mouse plasma. The extracts were analyzed by turbo ionspray liquid chromatography-tandem mass spectrometry (LC-MS-MS) in the positive ion mode. Sample preparation time for conventional LLE was dramatically reduced by the semi-automated 96-well LLE approach. The assay demonstrated a lower limit of quantitation of 0.02 ng/ml using 0.1-ml plasma sample aliquots. The calibration curves were linear from 0.02 to 10 ng/ml for reserpine. The intra- and inter-assay precision of quality control (QC) samples ranged from 1.75 to 10.9% for reserpine. The intra- and inter-assay accuracy of QC samples ranged from -8.17 to 8.61%. Reserpine and the I.S. were found to be highly bound to FVB/N mouse plasma protein. This is the first report of disodium EDTA employed as a special protein-bound release agent to recover protein-bound analytes from plasma. These matrix effects and the effects of pH in the HPLC mobile phase on the sensitivities of LC-MS-MS are discussed in this paper.

Animals↗

Analysis of clenbuterol in human plasma using liquid chromatography/atmospheric-pressure chemical-ionization mass spectrometry.

Clenbuterol is a beta-agonist drug used illegally as a growth stimulant in meat-producing animals and human athletes. The analysis of clenbuterol in spiked human plasma was performed using on-line liquid chromatography/atmospheric-pressure chemical-ionization mass spectrometry (LC/APCI-MS) using a conventional bore LC column (flow rate = 1.0 mL/min). At low sampling cone voltages, the mass spectrum was predominantly the [M+H]+ ion but diagnostic fragment ions were formed upon incremental increases in sampling cone voltage. The detection limit (signal-to-noise ratio of 3) using selected-ion monitoring of the [M+H]+ ion was 0.1 ng on-column (10 ppb). This is a 50-fold better sensitivity of detection than that previously reported for an on-line thermospray LC/MS method. The extraction procedures were not optimized for maximum sensitivity and the lack of interferences suggests that much lower detection limits for clenbuterol in plasma are attainable.

Clenbuterol↗

Identification of urinary acylcarnitines using gas chromatography-mass spectrometry: preliminary clinical applications.

Many disorders of organic acid metabolism are associated with abnormalities in the levels of acylcarnitines excreted in urine. Profiling of urinary acylcarnitines allows diagnosis and characterisation of many acidurias and acidemias, monitoring dietary treatment of such patients, and elucidation of the metabolism of some exogenous acidic compounds. Urine (ca. 0.5 ml) was subjected to a simple work-up by ion-exchange chromatography, and the isolated acylcarnitines were derivatized by cyclization in 35 min to give volatile lactones that are compatible with gas chromatography-mass spectrometry using electron or chemical ionization. The feasibility of this new and affordable procedure has been confirmed by identifying urinary acylcarnitines in cases of medium-chain acyl-coenzyme A dehydrogenase deficiency, propionic acidemia and isovaleric acidemia.

Acylation↗

Simple and unambiguous method for identifying urinary acylcarnitines using gas chromatography--mass spectrometry.

Several inherited metabolic disorders, particularly the organic acidurias and acidemias, are often characterised by excretion of acylcarnitines, especially octanoylcarnitine, in the urine. Clinical investigation of such serious disorders ideally requires a rapid, simple and selective method for determining acylcarnitines in urine. Initial results are given here of a method that may approach this ideal. The procedure involves chemical derivatisation, in which the zwitterionic acylcarnitines are cyclised to volatile lactones, and analysis by gas chromatography and gas chromatography--mass spectrometry. Preparation of urine samples by ion-exchange purification and an illustrative application of the proposed method to a clinical sample are also outlined.

Acetylcarnitine↗