Intrinsic uniformity and relative sensitivity quality control tests for single-head gamma cameras.

OBJECTIVE: We sought to determine the best parameters for rapid performance of daily quality control testing of intrinsic uniformity and relative sensitivity for the single-head gamma-camera system in our nuclear medicine department. METHODS: The effects of the following parameters on intrinsic uniformity were studied: gamma source activity, number of acquired counts for the flood image, source-to-camera distance, image matrix size, and source volume. The dead time of the system was determined experimentally using the two-source method for accurate calculation of relative sensitivity. RESULTS: A set of parameters for rapid performance of daily gamma-camera intrinsic uniformity and relative sensitivity was determined. The dead time of our gamma-camera system was found to be 4.5 +/- 0.2 micros. CONCLUSION: With our recommended parameters, the intrinsic uniformity and relative sensitivity quality control testing can be performed in 5-6 min. The dead time of each gamma-camera system must be determined experimentally in each nuclear medicine department.

Gamma Cameras↗

Supine bicycle versus post-treadmill exercise echocardiography in the detection of myocardial ischemia: a randomized single-blind crossover trial.

OBJECTIVES: We sought to determine the comparative accuracy of supine bicycle exercise echocardiography (SBE) and posttreadmill exercise echocardiography (TME) in detecting myocardial ischemia in patients with known or suspected coronary artery disease (CAD). BACKGROUND: Supine bicycle echocardiography and TME have been used for evaluation of CAD. However, the comparative accuracy of these modalities in the detection of ischemia in the same patients is not known. METHODS: Seventy-four patients (age 59 +/- 9 years [mean +/- SD]) referred for evaluation of coronary disease underwent SBE (starting at 25 to 50 W with 25-W increment every 3 min) and post-TME (Bruce protocol) in a random sequence. Digitized images at baseline and maximal exercise were interpreted in a random and blinded fashion. RESULTS: Maximal heart rate was higher during TME, whereas systolic blood pressure was higher during SBE, resulting in a similar double product. At quantitative angiography (n = 67), 57 patients had coronary stenosis (>50%). During SBE, ischemia was detected in 47 patients compared with 38 patients by TME (p < 0.001). Wall motion score index at maximal exercise was higher with SBE than with TME (1.48 +/- 0.51 vs. 1.38 +/- 0.43; p < 0.001). The extent of myocardial ischemia (number of ischemic segments) was higher during SBE compared with TME (3.3 +/- 3.4 vs. 2.3 +/- 2.9 segments; p = 0.004), whereas severity of abnormal wall motion was similar. The sensitivity of SBE and TME for CAD was 82% and 75% with a specificity of 80% and 90%, respectively. Image quality was similar with both techniques. Patients and sonographers favored SBE over TME. CONCLUSIONS: During SBE and TME exercise, patients achieve a similar double product. During SBE, however, the detection of ischemia is more frequent and more extensive which, along with patient and sonographer preference, makes supine bicycle exercise a valuable stress echocardiographic modality.

Adult↗

Three-dimensional electrophysiological imaging of the intact canine left ventricle using a noncontact multielectrode cavitary probe: study of sinus, paced, and spontaneous premature beats.

BACKGROUND: The feasibility of measuring cavitary electrograms using a noncontact probe and reconstructing endocardial surface electrograms and activation sequences during paced beats was previously demonstrated in the isolated canine left ventricle (LV). The objective of the present study was to develop and test a high-resolution, three-dimensional, endocardial electrophysiological imaging technique that simultaneously reconstructs endocardial surface electrograms and their corresponding activation sequences during normal and abnormal beats with the use of cavitary electrograms measured with a noncontact multielectrode probe in the intact canine LV. METHODS AND RESULTS: A 128-electrode probe was inserted into the intact canine LV. Probe unipolar electrograms were simultaneously acquired during sinus, artificially paced, and spontaneous premature beats. Representative endocardial electrograms were measured directly using eight needle electrodes (the "gold standard"). A probe-cavity realistic, three-dimensional geometric model was constructed using two-dimensional epicardial echocardiography. Boundary element methods and numeric regularization were used to compute electrograms at 194 sites on the endocardium. In eight pacing protocols, computed endocardial electrograms correlated well with directly measured electrograms (r=.88). Corresponding activation times were also in agreement with those determined from measured endocardial electrograms (activation error, 4.7 ms). The earliest region of activation was invariably in the vicinity of the pacing needle (spatial error, 9.2 mm). Subsequently, the site of origin of ischemia-induced spontaneous ventricular premature beats and the ensuing sequence of depolarization was identified. CONCLUSIONS: Noncontact mapping provides realistic, three-dimensional electrophysiological images of the endocardium, on a beat-by-beat basis, that localize the sites of origin of premature beats and reconstruct their activation sequences.

Animals↗

Atrial septal pacing: a method for pacing both atria simultaneously.

By pacing both atria simultaneously, one could reliably predict and optimize left-sided AV timing without concern for IACT. With synchronous depolarization of the atria, reentrant arrhythmias might be suppressed. We studied four male patients (73 +/- 3 years) with paroxysmal atrial fibrillation and symptomatic bradyarrhythmias using TEE and fluoroscopy as guides; a standard active fixation screw-in lead (Medtronic model #4058) was attached to the interatrial septum and a standard tined lead was placed in the ventricle. The generators were Medtronic model 7960. The baseline ECG was compared to the paced ECG and the conduction time were measured to the high right atrium, distal coronary sinus and atrial septum in normal sinus rhythm, atrial septal pacing, and AAT pacing. On the surface ECG, no acceleration or delay in AV conduction was noted during AAI pacing from the interatrial septum as compared with normal sinus rhythm. The mean interatrial conduction time for all 4 patients was 106 +/- 2 ms; the interatrial conduction time measured during AAT pacing utilizing the atrial septal pacing lead was 97 +/- 4 ms (P = NS). During atrial septal pacing, the mean conduction time to the high right atrium was 53 +/- 2 ms. The mean conduction time to the lateral left atrium during atrial septal pacing, was likewise 53 +/- 2 ms. We conclude that it is possible to pace both atria simultaneously from a single site using a standard active fixation lead guided by TEE and fluoroscopy. Such a pacing system allows accurate timing of the left-sided AV delay.

Aged↗