PubMed Health⌕ Search

Biomedical subjects

S M Berry

Publications and source records attributed to S M Berry.

At least 73 records · Page 4Linked to original sources

Ontogeny of pancreatic oncofetal antigen.

Serum concentration of pancreatic oncofetal antigen (POA) was determined in human fetuses, newborns and pregnant women. The mean fetal concentration of POA (mean = 5.27 micrograms/ml) changed very little with gestational age. Also, only a weak correlation was found between POA concentration of newborns (mean = 5.15 micrograms/ml) and their birth weight. It appears that between the 19th and 40th weeks of gestation POA exhibits no fetospecific features, i.e. POA concentration did not exceed significantly the concentration of nonpregnant adults (mean = 6.10 micrograms/ml). A number of pathophysiological variables was correlated with POA concentrations of newborns. The most striking statistical differences were found between American black and white newborns and adults; the mean concentration of POA in sera of black full-term newborns was 5.38 micrograms/ml as compared to white newborns, where the mean concentration was 3.58 micrograms/ml. Similarly, black mothers had a mean concentration (mean = 12.21 micrograms/ml) significantly greater than white mothers (mean = 5.62 micrograms/ml).

Adult↗

Infrapopliteal prosthetic graft patency by use of the distal adjunctive arteriovenous fistula.

From November 1979 through December 1989, 210 distal arteriovenous fistulas were constructed as adjuncts to tibial and peroneal vascular reconstructive procedures in 203 patients threatened with limb loss. Two-year cumulative patency rates were calculated by grouping patients on the basis of changing indications in sequential time periods: group 1 (n = 61): 1979 to 1983, 18%; group 2 (n = 80): 1983 to 1986, 33%; group 3 (n = 69): 1986 to 1989, 44%. Although the therapeutic results observed in these groups are not statistically comparable, they show a perceptible trend. Postoperative arteriography showed that flow is prograde in the distal vessels beyond the distal arteriovenous fistula. Graft surveillance by duplex ultrasonography also confirmed that flow in the distal arteries is prograde and that "steal" does not occur. Peak systolic velocity (174 +/- 38 cm/sec) and mean velocity (92 +/- 23) flow rates are increased in grafts with patent distal arteriovenous fistulas compared to those bypasses with closed distal arteriovenous fistulas (p less than 0.01). There were no differences in the flow measurements for the arteries beyond the distal anastomoses and distal arteriovenous fistulas, confirming the prograde nature of the distal flow. In 22 patients analysis of graft and fistula patency by duplex sonography showed that one fourth of all grafts were patent without fistulas at 1 and 2 years after operation. Alternatively, 68% of patent grafts at 1 year had patent fistulas and 58% had patent fistulas at 2 years. We conclude that the distal arteriovenous fistula will increase graft flow and simultaneously prevent distal arterial overload without causing "steal." This technique should be considered whenever a prosthetic graft is necessary for crural reconstruction and only in selected instances of revascularization with autologous veins.

Adult↗

Fetal holoprosencephaly: associated malformations and chromosomal defects.

In 38 fetuses with holoprosencephaly, cordocentesis and blood karyotyping was performed. The karyotype was normal in all 12 cases with isolated holoprosencephaly, and in all 5 with holoprosencephaly and facial defects only. In contrast, 11 of the 21 (52%) fetuses with extrafacial malformations were chromosomally abnormal [47xx+13, n = 6; 47xy+13, n = 2; 47xx+18, n = 1; 46xx-18+i(18q), n = 1; 46xy 21q-, n = 1]. In the chromosomally normal group, there was parental consanguinity in 2 cases and recurrence of holoprosencephaly in 3.

Adult↗

Optic nerve decompression via the lateral facial approach.

Two cases of visual loss after lateral orbital wall fracture are presented: one with retrobulbar hematoma and evidence of optic nerve compression who failed to respond to lateral canthotomy and high-dose corticosteroid administration, and the second with immediate, total blindness associated with fracture of the bony optic canal. In both, extradural decompression of the orbit and optic nerve was achieved through the lateral facial approach with partial return of visual acuity and without surgical complications. The role of orbital and optic nerve decompression in the management of patients with blindness following orbital trauma is controversial. Orbital decompression may be of value for cases of post-traumatic visual loss unresponsive to medical management. If optic nerve injury is suspected as the cause, the additional step of decompression of the optic nerve is a logical but unproven procedure. The indications for optic nerve decompression are not established and should be considered only within the context of the specific needs of the individual patient.

Adult↗

Degradation of bovine corneal collagen by alkali.

This study was undertaken to demonstrate the effect of alkali on the molecular size of collagen. Type I and V collagen from bovine cornea were incubated with different concentrations of NaOH at room temperature and 37 degrees C for various times. The samples were then neutralized and analyzed by high-pressure liquid chromatography and sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Degradation of collagen molecules to a heterogeneous mixture of peptides with molecular weights less than 20,000 daltons occurred at concentrations greater than 0.25N, and the effect of alkali was much faster at 37 degrees C than at room temperature. In contrast, the molecular size of collagen was not affected by similar concentrations of HCl under similar conditions of time and temperature.

Alkalies↗

A decade of experience with the glutaraldehyde-tanned human umbilical cord vein graft for revascularization of the lower limb.

Between October 1975 and November 1985, 907 lower limb bypasses were constructed in 715 patients (799 limbs) with glutaraldehyde-stabilized umbilical veins (UV-G) used as the predominant, or sole, graft material. Each reconstruction was classified in one of eight categories depending on the site of the distal anastomosis: above- and below-knee popliteal, anterior and posterior tibial, peroneal, trifurcation, sequential, and crural (tibial or peroneal) bypasses with adjunctive distal arteriovenous fistulas. Primary and secondary cumulative graft patency rates were determined for each category as well as cumulative actual palliation that combines end points of graft failure, amputation, and death. Half-life patencies for popliteal, tibial, and peroneal bypasses were 6.5, 2.3, and 1.7 years, respectively. Perioperative graft thrombosis occurred in 11% of popliteal reconstructions compared with 22% for the crural group. Nonocclusive graft failure caused by infection, aneurysm, or progressive foot gangrene occurred in 87 grafts (8%). The overall infection rate was 4.3%. Anastomotic aneurysms (1.4%) and strictures (2.1%) occurred infrequently as isolated phenomena. The incidence of graft dilatation and aneurysms assumed significant proportion after 5 years (36% aneurysms and 21% dilation); the diagnosis was particularly facilitated by B-mode imaging. Nevertheless, the overall clinical impact of graft degradation remained minimal (6% after 5 years). Twenty-two of 26 graft aneurysms were excised with successful graft replacement achieved in 10. During this 10-year period, our attitudes did change with regard to the indication for UV-Gs in relation to the maturation of infrapopliteal reconstructive surgery, appreciation of the superior results attainable with in situ saphenous vein, recognition of morphologic changes in long-term UV-G implants, and the growing documentation of poor results with polytetrafluorethylene in the crural position. We believe that UV-G is an acceptable alternative to the absent or deficient autologous vein, particularly in patients with limited life expectancy and where expediency may be a critical factor.

Adolescent↗

Evidence of contralateral ovulation in ectopic pregnancy.

Patients with an ectopic pregnancy were studied for documentation of the site of ovulation in order to determine the frequency with which controlateral ovulation and ovum transport occurs. Analysis of data on 135 patients in whom the site of ovulation was documented at the time of surgery and on 24 patients who were studied ultrasonically before surgery indicates that contralateral ovulation and ovum transport occurs in at least a third of ovulatory events.

Female↗

Ultrasonic imaging and oculoplethysmography in diagnosis of carotid occlusive disease.

Pulsed Doppler ultrasonic imaging (UI) of the cervical carotid artery provides flow-dependent anatomic detail of the carotid bifurcation, while oculoplethysmography (Kartchner) (OPG-K) and ocular pneumoplethysmography (Gee) (OPG-G) reflect changes in flow and pressure resulting from hemodynamically significant lesions. We examined 66 patients prospectively with UI, OPG-K, and OPG-G to compare the relative accuracy of these techniques with contrast arteriography. Both UI and OPG-G were significantly more accurate than OPG-K. While the accuracies of UI and OPG-G were not significantly different, their combined use resulted in a significant increase in sensitivity compared with that of Doppler imaging alone. In addition, UI correctly identified 22 (85%) of 26 occlusions of the internal carotid artery. The use of UI and OPG-G together provided accurate anatomic and hemodynamic information useful in the evaluation of carotid occlusive disease.

Arterial Occlusive Diseases↗

The role of real-time B-mode ultrasonography and ocular pneumoplethysmography following carotid endarterectomy.

Real-time B-mode ultrasonography and ocular pneumoplethysmography (OPG-G) were used to evaluate 41 patients (54 arteries) following carotid endarterectomy. Thirteen patients had bilateral procedures. Recurrent stenosis was observed in three (6%), and postoperative occlusion in three (6%). In one symptomatic patient, the origin of an occluded external carotid artery was the source of atheroemboli. Only two of the seven patients were symptomatic and three of the seven had hemodynamically insignificant stenoses. Of the three patients with recurrent stenosis, two had a normal OPG-G and demonstrated the value of combinate noninvasive evaluation. The noninvasive diagnosis in these two cases was based on B-mode ultrasonography. Of the three postoperative occlusions, one had a normal OPG-G. Since the OPG-G cannot distinguish stenosis from occlusion, B-mode ultrasonography was necessary to demonstrate the presence of an occluded internal carotid artery and the absence of internal carotid flow in each case. B-mode ultrasonography also permitted the identification of several characteristic postoperative findings. An intimal shelf was often observed, corresponding to the proximal limit of the endarterectomy. Seventy-four per cent demonstrated thickening of the arterial wall and 45 per cent were observed to have calcification in the area of the endarterectomy. The true incidence of recurrent disease following carotid endarterectomy is uncertain, but it probably exceeds those estimates based on symptomatic recurrence. Because of the incidence of asymptomatic and/or hemodynamically insignificant disease, we recommend the routine use of noninvasive studies following carotid endarterectomy.

Arterial Occlusive Diseases↗

Oculoplethysmography and pulsed Doppler ultrasonic imaging in diagnosis of carotid arterial disease.

The individual and combined diagnostic accuracy rates for fluid-filled oculoplethysmography and pulsed Doppler ultrasonic imaging in the detection of extracranial carotid artery insufficiency were calculated. Results of the two techniques were compared with those of contrast arteriograms which were available for 109 patients, 210 arteries, for computations of sensitivity and specificity. Sensitivities for oculoplethysmography and ultrasonic imaging were 84 and 87 per cent, while specificities were 87 and 81 per cent, respectively. These values were not significantly, p greater than 0.05, different. Results of oculoplethysmography and ultrasonic imaging agreed in four-fifths of the arteries, producing a sensitivity of 98 per cent and a specificity of 97 per cent. In the remaining arteries, the results of the two tests did not agree, resulting in a sensitivity of 71 per cent and a specificity of 79 per cent. Fluid-filled oculoplethysmography and pulsed Doppler ultrasonic imaging are diagnostic tests of comparable accuracy which, when used together, provide accurate hemodynamic and anatomic information in the diagnosis of extracranial carotid arterial disease.

Adult↗

Real-time B-mode ultrasonography of the femoral arteries: comparison to contrast arteriography.

Forty-five patients with symptomatic peripheral vascular disease were studied with a high-resolution, real-time B-mode echo imaging system for visualization of the femoral arteries. Common femoral and superficial femoral arteries were visualized in over 88 per cent of cases, whereas the profunda femoris artery was demonstrated in only about one-third of cases. Stenotic lesions (+ or - 20% of arteriographic assessment) were identified in two-thirds of cases. Prostheses and grafts in the proximal and medial cases. Prostheses and grafts in the proximal and medial thigh were well visualized. Anatomic information provided by B-mode imaging will complement functional assessments of lower extremity vascular insufficiency.

Aged↗

Capabilities and limitations of pulsed Doppler sonography in carotid imaging.

Pulsed Doppler ultrasonic imaging of the extracranial carotid arteries was performed in 118 patients (226 arteries) in whom selective contrast arteriograms were available for comparison to ultrasonic images. Specificity for the detection of normal and stenosis less than 50% was 84%, whereas sensitivity for detecting stenosis greater than 50% and occlusion of the internal carotid arteries was 89%. Overall accuracy was 85%. Capabilities and limitations in the use of the technique are presented in selected case reports.

Adult↗

Comparison of pulsed Doppler and real-time B-mode echo arteriography for noninvasive imaging of the extracranial carotid arteries.

Accuracy and clinical applications of noninvasive imaging of the extracranial carotid arteries were compared using pulsed Doppler and real-time B-mode ultrasonography. During the period December, 1977, to February, 1979, 530 ultrasonograms (265 patients) were performed. Angiographic correlations were available in 90 patients (172 arteries) using the pulsed Doppler technique, and both techniques were employed in 43 patients (84 arteries). Greatest accuracy with pulsed Doppler ultrasonography occurred in confirmation of normal vasculature (73%) and diagnosis of occluded internal carotid arteries (96%). Estimation of the percentage of stenosis was less accurate; however, this determination could be made somewhat more accurately by B-mode ultrasonography. Incidence of false positive and negative results for the pulsed Doppler technique was 11% and 14%, respectively, whereas for the corresponding incidence for B-mode imaging it was 11% and 59%. The higher incidence of false negative results with the B-mode technique related to its inaccuracy in diagnosis of occlusion (18%). Current clinical applications of carotid ultrasonography include confirmation of normalcy and diagnosis of occlusion, visualization of atheroslerotic plaques with characterization of their size and ultrasonic morphology, and an anticipated reduction in the requirements for contrast arteriography in selected patients.

Aged↗

Hosiery.

Explore the source record for details and available documents.

Clothing↗

Preliminary experience with triamcinolone acetonide during pregnancy.

Although inhaled corticosteroids have been recommended, there are no published reports of triamcinolone acetonide therapy for asthma during pregnancy. The objective of this study was to report our experience with triamcinolone acetonide during pregnancy. This was a retrospective cohort study in a tertiary care urban hospital. We compared birth weights and the proportion of subjects hospitalized for asthma exacerbations among pregnant women receiving inhaled triamcinolone acetonide, inhaled beclomethasone dipropionate, and oral theophylline. The mean triamcinolone acetonide group (n = 15) birth weight was 502 g more than the beclomethasone group (n = 14) and 316 g more than the theophylline group (n = 25); however, these differences were not statistically significantly. Fewer patients treated with triamcinolone acetonide (n = 5, 33%) required hospital admissions for asthma exacerbations compared to those treated with beclomethasone (n = 11, 79%; P < 0.05) but not theophylline (n = 7, 28%; P = NS). Our preliminary data suggest that triamcinolone acetonide appears to be at least as efficacious for the treatment of asthma during pregnancy as is beclomethasone. These results should be confirmed by a clinical trial to further evaluate the safety and efficacy of inhaled triamcinolone acetonide during pregnancy.

Administration, Inhalation↗

Influence of maternal-fetal medicine subspecialization on the frequency of trial of labor in term pregnancies with breech presentation.

OBJECTIVE: To investigate the role of subspecialization in maternal-fetal medicine (MFM) on the frequency of a trial of labor in term pregnancies with breech presentation. METHODS: We conducted a retrospective study of 332 singleton pregnancies > or =37 weeks with nonfootling breech presentation that delivered over a 6-year period (1994-1998) at a university-based, tertiary care hospital. Patients were divided into two groups based on whether the delivery was attended by an MFM or non-MFM obstetrician-gynecologist. Demographic and clinical data were compared between groups and outcome variables included whether the patient had an attempt at vaginal delivery, cesarean delivery after a labor attempt, or vaginal breech delivery. RESULTS: The frequency of labor attempt (OR 1.4, 95% CI 0.9-2.3), vaginal breech success rate (OR 0.6, 95% CI 0.3-1.5), and overall cesarean rates (OR 0.9, 95% CI 0.5-1.7) were similar between groups. Using discriminant function analysis, only nulliparity (R2 = 1.6%, F = 6.0, P = 0.005) and birthweight (R2 = 2.0% F = 6.4, P = 0.01) were associated with trial of vaginal delivery. CONCLUSIONS: Subspecialization in MFM had no impact on the frequency of trial of labor in the term pregnancy with a breech presentation.

Adult↗