PubMed Health⌕ Search

Biomedical subjects

S M Crooks

Publications and source records attributed to S M Crooks.

5 recordsLinked to original sources

Aperture modulated arc therapy.

We show that it is possible to translate an intensity modulated radiation therapy (IMRT) treatment plan and deliver it as a single arc. This technique is referred to in this paper as aperture modulation arc therapy (AMAT). During this arc, the MLC leaves do not conform to the projection of the target PTV and the machine output of the accelerator has a constant value. Dose was calculated using the CORVUS 4.0 IMRT system, which uses a pencil beam dose algorithm, and treatments were delivered using a Varian 2100C/D Clinac. Results are presented for a head and neck and a prostate case, showing the equivalence of the IMRT and the translated AMAT delivery. For a prostate AMAT delivery, coronal plane film dose for the IMRT and AMAT deliveries agreed within 7.19 +/- 6.62%. For a meningioma the coronal plane dose distributions were similar to a value of 4.6 +/- 6.62%. Dose to the isocentre was measured as being within 2% of the planned value in both cases.

Algorithms↗

Application of constrained least-squares techniques to IMRT treatment planning.

PURPOSE: The purpose of this work was to apply the method of constrained least-squares to inverse treatment planning and to explore its potential for providing a fast interactive planning environment for intensity-modulated radiation therapy (IMRT). METHODS AND MATERIALS: The description of the dose inside a patient is a linear matrix transformation of beamlet weights. The constrained least-squares method adds additional matrix operators and produces beamlet weights by a direct linear transformation. These matrix operators contain a priori knowledge about the radiation distribution. The constrained least-squares technique was applied to obtain IMRT plans for prostate and paraspinal cancer patients and compared with the corresponding plans optimized using the CORVUS inverse planning system. RESULTS: It was demonstrated that a constrained least-squares technique is suitable for IMRT plan optimization with significantly increased computing speed. For the two cases we have tested, the constrained least-squares method was an order of magnitude faster than conventional iterative techniques because of the avoidance of the iterative calculations. We also found that the constrained least-squares method is capable of generating clinically acceptable treatment plans with less trial-and-error adjustments of system variables, and with improved target volume coverage as well as sensitive structure sparing in comparison with that obtained using CORVUS. CONCLUSIONS: The constrained least-squares method has the advantage that it does not require iterative calculation and thus significantly speeds up the therapeutic plan optimization process. Besides shedding important insight into the inverse planning problem, the technique has strong potential to provide a fast and interactive environment for IMRT treatment planning.

Algorithms↗

Minimizing delivery time and monitor units in static IMRT by leaf-sequencing.

Intensity-modulated radiation therapy (IMRT) requires the determination of the appropriate multileaf collimator settings to deliver an intensity map. The purpose of this work was to attempt to reduce the number of segments required for IMRT delivery and the number of monitor units required to deliver an intensity map. An intensity map may be written as a matrix. Leaf sequencing was formulated as a problem of decomposing the matrix into a series of sub-matrices. Sets of random intensity matrices were created and the segmentations produced by applying different algorithms were compared. The number of segments, important if verification and record (VR) overhead is significant, and beam on times were examined. It is shown that reducing the value of the matrix entries by the maximum amount at each stage results in the smallest number of steps. Reducing the 2-norm (sum of the squares) of the matrix entries by the maximum amount at each step results in the smallest beam on time. Three new algorithms are introduced, two of which produce results that are superior to those generated by the algorithms of other researchers. The resulting methods can be expanded upon to include tongue and groove effects and leaf inter-digitization. With square random matrices of the order 15, the reduction in beam time and segmentation is up to 30-40%. Compared to previous algorithms, those presented here have demonstrated a reduction in the beam on time required to deliver an intensity map by 30-40%. Similarly, the number of segments needed to deliver an intensity map is also reduced.

Algorithms↗

Linear algebraic methods applied to intensity modulated radiation therapy.

Methods of linear algebra are applied to the choice of beam weights for intensity modulated radiation therapy (IMRT). It is shown that the physical interpretation of the beam weights, target homogeneity and ratios of deposited energy can be given in terms of matrix equations and quadratic forms. The methodology of fitting using linear algebra as applied to IMRT is examined. Results are compared with IMRT plans that had been prepared using a commercially available IMRT treatment planning system and previously delivered to cancer patients.

Dose-Response Relationship, Radiation↗