A classification of facial wrinkles.

An increasing number of injectable filler materials for facial wrinkles and folds points to the need for objective measurements of their effectiveness. Patient satisfaction is the goal, but proof of the value of a particular product requires objective measurement. A wrinkle assessment scale was developed as a simple tool for use by plastic surgeons, dermatologists, and aesthetic surgeons who want to assess the changes resulting from injecting filler materials in their patients. By correlating the grade of the wrinkle in the reference photographs with the wrinkle in a patient's face, a classification of 0 to 5 is assigned. Reliability of the scale was assessed by "live" judgment of 76 wrinkles by nine observers. The same rating was given to 92.7 percent of all wrinkles. In a second trial, photographs from 130 wrinkles were presented to eight observers who rated 89.4 percent of all wrinkles equally. A significant correlation of 87 percent was found between subjective ratings and objective wrinkle depth measured by profilometry on 40 silicone impressions. Manufacturers, monitors of clinical trials, health authorities, and most important, patients will benefit from objective data on current and new injectable materials.

Absorbable Implants↗

[Osteoplasty of extensive jaw defects by protected bone regeneration using large pore resorbable implant].

This study was performed to demonstrate a protected bone regeneration method using macroporous resorbable sheets for the treatment of extended lower and upper jaw defects. By applying mechanical protection of bony defects with, e.g. membranes or titanium mesh, soft tissue prolapse as well as pressure on bone transplants which contributes to partial resorption can be avoided. The use of a pressure-resistant, resorbable, macroporous sheet combines the advantage of protected bone regeneration and complete resorption of the implanted sheet. The macroporous structure facilitates capillary ingrowth from the surrounding soft tissue. The sheet is made of 70:30 Poly(L-co-DL)-lactate with thermoplastic character and can be used as a container for autologous spongiosa or other osteoinductive and -conductive bone graft substitutes. In a pilot study, seven patients with lower jaw defects resulting from large cysts or tumor resections, some affecting the continuity of the mandible, were treated with this method. Following a protocol, X-rays were obtained to document the bony regeneration. The positive experience with this pilot study encouraged a multicenter project involving five university hospitals and 50 patients. The application of resorbable sheets in combination with transplantation of mersilized autologous spongiosa is currently being investigated. In future studies, fillings of sheets with osteoconductive and -inductive materials are planned.

Aged↗

Bone response to implant surface morphology.

This study was designed to measure implant osseointegration using different surface treatments. Bilateral distal intramedullary implantation of titanium cylinders 25 mm x 5 mm was performed in 60 rabbits. The 3 surfaces tested were fiber mesh, mean pore size 400 microns; grit-blasted, mean surface roughness 6 microns; and acid-etched, mean surface roughness 18 microns. Scanning electron microscopy was used to measure the percentage of the surface of each implant in contact with bone at 2, 6, and 12 weeks postimplantation. Mechanical pull-out testing of the bone-implant interface was performed at 12 weeks. Overall, acid-etched surfaces demonstrated greater mean osseointegration than fiber mesh surfaces. All 3 surfaces demonstrated similar interface strengths. Acid etching has potential as a means of enhancing bony apposition in cementless fixation.

Animals↗

Bony healing of large cranial and mandibular defects protected from soft-tissue interposition: A comparative study of spontaneous bone regeneration, osteoconduction, and cancellous autografting in dogs.

The purpose of this study was to compare spontaneous bone regeneration, osteoconduction, and bone autografting in critical size calvarial and mandibular defects (defects which do not heal spontaneously during the lifetime of the animal) that were protected from soft-tissue interposition. Eighteen adult mongrel dogs underwent osteotomies to create a unilateral 30-mm segmental defect in the midbody of the edentulated right mandible and bilateral 15-mm x 20-mm full-thickness window defects in the parietal bones. The defects were either left empty, implanted with coralline hydroxyapatite (HA) blocks, or autografted with iliac cancellous bone. All defects were protected with a macroporous titanium mesh and the segmental mandibular defects were additionally stabilized by internal plate fixation. Specimens were retrieved after 2 and 4 months and three undecalcified longitudinal central sections including the osteotomy interfaces were prepared from each specimen for histometry and histology. Sections were analyzed for volume fractions of bone, soft tissue, and implant using scanning electron microscopy, backscatter electron imaging and histometric computer software. In the mandibular model, the empty defects exhibited the greatest amount of bone formation after 4 months (47.3 percent), which was greater than the amount of bone in the autografted group (34.8 percent) and significantly greater than the amount of bone within the hydroxyapatite implants (19.0 percent, p < 0.05). In the cranial defects, the autografted specimens demonstrated the greatest volume fraction of bone after 4 months (27.3 percent), which was significantly greater than within both the empty defects (18.2 percent, p < 0.05) and the hydroxyapatite implants (18.2 percent, p < 0.05). New bone formation in the mandibular defects united the cut ends at 4 months regardless of treatment and originated predominantly from the periosteum which remained present only along the alveolar border after surgical closure. In the calvarial defects, periosteum was not preserved and bone regenerated centripetally, originating from the diploë without any evidence of dural osteogenesis. Bone bridging was incomplete in the empty cranial defects at 4 months. In both the mandibular and cranial specimens, new bone at 2 months was a mixture of woven and parallel fibered bone. At 4 months, the new bone had remodeled almost entirely into mature Haversian bone. This study demonstrated a remarkable ability of defect protection with a macroporous protective sheet to facilitate bone regeneration in critical size mandibular and cranial bone defects. When active osteogenic periosteum was present, as in our mandibular model, we concluded that defect protection alone was sufficient to allow for healing even of critical size defects. When periosteum was absent as in our cranial defects, the limited spontaneous bone formation benefited from the added contributions of cancellous grafting and osteoconductive implants, both of which promoted bone bridging across the defects. We suggest that in the future a resorbable macroporous protective sheet would be advantageous in comparison to a titanium mesh to facilitate bone regeneration by preventing soft-tissue prolapse and allowing the migration of mesenchymal cells and the proliferation of blood vessels from the adjacent soft tissues into the bone defect. Finally, this study identified the need to differentiate critical size defects into those with and without defect protection and periosteum.

Animals↗

Coralline hydroxyapatite bone graft substitutes. Evaluation of bone density with dual energy x-ray absorptiometry.

RATIONALE AND OBJECTIVES: The authors evaluate whether dual-energy x-ray absorptiometry (DXA) is a reliable method to determine the density of natural coralline hydroxyapatite (HA) blocks used as bone graft substitutes. METHODS: To evaluate the basic density of HA blocks from the same coral heads with and without titanium meshes, densitometry of 12 HA-500 blocks (genus Goniopora) and 12 HA-200 blocks (genus Porites) was performed. In addition, density measurements of 30 HA blocks (HA-500, n = 15; HA-200, n = 15) from different coral heads were obtained to assess if the originating coral head influences the basic density of blocks within one coral genera. To assess standard deviation serial measurements on eight coralline HA blocks, four with titanium meshes and four without were performed. In the ex vivo study, densitometry of 12 HA blocks (HA-500, n = 4; HA-200, n = 8) used as bone graft substitutes in the mandibles and craniums of adult mongrel dogs was performed. Densities were measured after bone ingrowth for 2 and 4 months, respectively. All measurements were obtained with a Lunar DPX with scan mode "slow 750" in the spine program with the regions-of-interests selected manually. Bone ingrowth was assessed by computer-assisted histomorphometry, which was considered the gold standard. Statistical analysis was performed to correlate the densities of plain HA blocks with and without meshes to the specific weights of the blocks. RESULTS: Significant positive correlation was found between the density of each HA block (both coral species) with and without meshes and the calculated specific weights. Densitometry values showed no significant differences depending on the originating coral heads. Standard deviation ranged between +/- 3.8% and +/- 4.1% (HA-500) and between +/- 3.0% and +/- 3.8% (HA-200). Hydroxyapatite-500 blocks showed marked increased densities between 15% and 34% after 4 months in three specimens in which bone ingrowth between 16.9% and 21.1% was revealed by histomorphometry; no increase of density was observed in one specimen, which presented only minimal bone ingrowth and signs of infection. Despite bone invasion between 12% and 25.8%, no increased densities were observed for HA-200 implants. CONCLUSIONS: Dual-energy x-ray absorptiometry is an accurate and reproducible modality to assess the densities of plain coralline HA blocks and to monitor bone ingrowth into coralline HA-500 but not into HA-200 block implants.