PubMed Health⌕ Search

Biomedical subjects

S M Wright

Publications and source records attributed to S M Wright.

112 records · Page 7Linked to original sources

An automated measurement system for characterization of RF and gradient coil parameters.

A fully automated laboratory-based measurement system for characterization of coil system parameters is presented. This method uses an inexpensive personal computer (PC)-controlled stepper motor positioning system in conjunction with a network/spectrum analyzer and an analog-to-digital converter (A/D) board that allows high resolution data acquisition in an unattended manner. A graphical interface was created for complete control of stepper motor movement, measurement, and data acquisition. The system is capable of performing a wide range of measurements that can, either individually or combined, characterize radiofrequency (RF) and gradient coils used in MRI. Measurement methods, theory, and results for conductor and shield current distributions, mutual impedance, and magnetic fields are given. Comparisons with theoretical calculations are included to validate the accuracy and utility of the system.

Calibration↗

Recovery of erythrocyte Li+/Na+ countertransport and choline transport from lithium therapy.

Li+/Na+ countertransport, choline transport, and intracellular Li+ and choline were measured in the RBC of a manic-depressive subject as a function of time after termination of Li+ therapy. Countertransport recovered from its inhibition by Li+ in 10 days. This recovery involved a decrease in the Michaelis-Menten parameter Km, without change in Vmax. RBC choline decreased, and choline influx rose, much more slowly back towards pre-Li+ values over the course of two months. Thus, choline transport was still inhibited long after Li+ levels in RBC and plasma had become undetectable. Measurements on age-separated RBC fractions showed that recovery of choline transport was mainly in the young-cell fraction. Hence inhibition of choline transport by Li+ may be irreversible at the level of the individual RBC.

Bipolar Disorder↗

A multi-plane scout sequence using flash imaging.

A new pulse sequence is presented for multi-plane imaging which simultaneously acquires images in the axial, coronal, and sagittal planes. Combined with FLASH imaging or other similar techniques, T1- and T2-weighted images in all three planes can be acquired in approximately 12 and 30 seconds, respectively. The sequence is easily implemented by modifying a multi-slice sequence to provide a rotation of gradient assignments between slice excitations. This sequence has been used extensively as a rapid "scout" scan. Several clinical examples are included.

Arachnoid↗

The polished surface contour: a new approach.

Proper shaping of the polished surface of a denture is important to facilitate the intraoral manipulation and control of the prosthesis by the patient. A method for the assessment of the polished surface form and tooth position in processed dentures is described. Low-viscosity silicone impression material is placed on the dentures, and the patient's chewing movements are used to define those areas requiring modification.

Dental Impression Materials↗