PubMed Health⌕ Search

Biomedical subjects

S Maitrejean

Publications and source records attributed to S Maitrejean.

3 recordsLinked to original sources

A novel sensitive microarray approach for differential screening using probes labelled with two different radioelements.

We have developed a novel microarray approach for differential screening using probes labelled with two different radioelements. The complementary DNAs from the reverse transcription of mRNAs from two different biological samples were labelled with radioelements of significantly different energies (3H and 35S or 33P). Radioactive images corresponding to the expressed genes were acquired with a MicroImager, a real time, high resolution digital autoradiography system. An algorithm was used to process the data such that the initially acquired radioactive image was filtered into two subimages, each representative of the hybridisation result specific for one probe. The simultaneous screening of gene expression in two different biological samples requires <100 ng mRNA without any amplification. In such conditions, the technique is sensitive enough to directly quantify the amount of mRNA even when present in small amounts: 10(7) molecules in the probe as assessed with an added control sequence and 2 x 10(5) molecules with an endogenous tyrosine hydroxylase mRNA. This novel technique of double radioactive labelling on a microarray is thus suitable for the comparison of gene expression in two different biological samples available in only small quantities. Consequently, it has great potential for various biological fields, such as neuroscience.

Animals↗

Sensitive and quantitative co-detection of two mRNA species by double radioactive in situ hybridization.

A better understanding of biological phenomena involving modulations of gene expression requires quantitative analysis of the expression of several genes in the same structure. For this purpose, we have developed a novel in situ hybridization method to quantify two different mRNA species in the same tissue section simultaneously. Two probes labeled with radioelements of significantly different energies ((3)H and (33)P or (35)S) were used to detect the mRNA species. Radioactive images corresponding to the detected mRNA species were acquired with a Micro Imager, a real-time, high-resolution digital autoradiography system. An algorithm was used to process the data such that the initial radioactive image acquired was filtered into two subimages, each representative of the hybridization result specific to one probe. This novel method allows local discrimination and quantification of the respective contributions of each label to each pixel and can therefore be used for quantitative analysis of two mRNAs with a resolution of 15-20 microm.

Algorithms↗

A new high resolution radioimager for the quantitative analysis of radiolabelled molecules in tissue section.

We present a high-speed, high-resolution imager of beta particles. It is devoted to be used in autoradiography experiments such as receptor binding or in situ hybridization experiments, either instead of, or in complement with autoradiographic film and emulsions. It allows the user to locate and perform quantitative analyses of (3H, 14C, 35S, 33P, 32P, 125I) labelled molecules with a 15 microm spatial resolution on a 0.9 x 1.3 cm2 sensitive area. Combining recent techniques (specific scintillator thin sheets and intensified charge-coupled device (CCD)) this imager offers a wide dynamic range and real-time acquisition.

Animals↗