Publications and source records attributed to S Mandolfo.

At least 19 recordsLinked to original sources

Evaluation of hygiene and safety controls for on-line paired hemodiafiltration (PHF).

BACKGROUND: On-line hemodiafiltration is gaining popularity due to increasing evidence of clinical benefits however it also requires strict attention to hygiene and safety as notable quantities of liquid are reinfused into the patient. Although most centers are improving their attention to water quality, a frequent concern is the inadvertent or accidental contamination of water and whether the redundant safety controls are sufficient to protect the patient. In the present study, in order to simulate a worst-case safety condition, we tested in vitro the reliability of paired hemodiafiltration - (PHF), under low, moderate and high bacterial contamination of the water supply. Tests were performed using various bacterial concentrations (range 85-2000 cfu/mL) of Pseudomonas Aeruginosa. Samples were analyzed from different sites throughout the entire on-line hemodiafiltration circuit for bacteria endotoxin, fungus and ability to stimulate whole blood production of TNFalfa. RESULTS: In the in vitro contamination study, with the three bacterial concentrations tested at various points of the circuit, bacteria were below the level of detection and endotoxins were < 0.01 UE/mL. Addition of dialysate samples taken after the first stage of microfiltration, as well as after the first and second stage of ultrafiltration and incubated with whole blood were not associated with stimulated production of TNFalfa . CONCLUSIONS: PHF appeared to be a safe and feasible method for on-line hemodiafiltration even in the unforeseen presence of bacterial contamination of the feed water or water distribution system.

Endotoxins↗

Leptin and beta2-microglobulin kinetics with three different dialysis modalities.

BACKGROUND: Leptin is a protein produced by fat cells and involved in body weight regulation. In patients with normal kidney function, leptin has been considered an independent predictor of cardiovascular events. In uremic patients, leptin in plasma serum was assumed to be associated with malnutrition, inflammation and atherosclerosis. Because of its molecular weight and characteristics, leptin can be considered as a protein-bound uremic retention solute. Some authors have reported the possibility of decreasing the serum leptin concentration with high flux membranes, but limited data are available on the elimination with medium-flux membranes or alternative dialysis strategies such as hemodiafiltration. METHODS: We evaluated the kinetics of leptin and beta2m in a study of 18 chronic hemodialysis patients using low-flux, medium-flux and high-flux biocompatible membranes, the last one used in hemodiafiltration (HDF). Blood samples for leptin and beta2m were collected pre- and post-treatment and 30 minutes after the end of treatment, over a 1-week period that included 3 dialysis sessions. Clearances of leptin and beta2m across the dialyzer were also determined directly from the arterial and venous blood concentrations 60 and 210 minutes after starting dialysis. RESULTS: At baseline, all groups showed similar leptin (18.8+/-4.4 ng/mL) and beta2m concentrations (29.2+/-7.1 ng/mL). After a single dialysis session, a reduction of both solutes was observed with HDF (39.8+/-1.9%, 78.1+/-4.9) and medium flux membranes (18.2+/-0.9%, 52.2+/-1.7%), whereas the concentrations remained unchanged with the low-flux membranes. After one-week period, a trend of reduction of plasma pre dialysis leptin and beta2m were observed with HDF and medium flux membranes. At 60 minutes, HDF showed the best instantaneous clearance across the filter for leptin (56.2+/-10.1 ml/min) and beta2m (75.3+/-4.4 ml/min). The magnitude of post dialysis rebound of leptin at 30 min was variable and strongly correlated with the instantaneous clearance of the solute (r2= 0.88). CONCLUSIONS: Leptin serum concentration can be influenced by dialysis modalities and membrane permeability; data on rebound suggest a multicompartimental kinetic of leptin similar to beta2m. Leptin removal, as measured by the reduction rate, can be considered as an index of dialysis efficiency for protein-bound uremic retention solutes.

Aged↗

Von Willebrand factor and autoantibodies against oxidized LDL in hemodialysis patients treated with vitamin E-modified dialyzers.

Oxidant stress is a well known cause of damage in the atherosclerotic process. Vitamin E is one of the most promising natural antioxidants. In this study we investigated if a vitamin E-coated dialyzer was able to reduce the plasma levels of auto-antibodies against oxidized-LDL, von Willebrand factor (vWf) and thrombomodulin (TM) as markers of endothelial damage. In this controlled 6-month prospective study, we investigated these markers in two matched groups (n=16 each) of patients on regular hemodialysis not yet diagnosed for atherosclerosis cardiovascular disease (ACVD) (mean age=58.3+/-7.0 yrs, mean dialysis age=30.1+/-10.0 months), in which cellulosic (CLS) and vitamin E-modified dialyzers (CLE) were compared. At inclusion all the patients were treated with CLS. Then, the study group was shifted to CLE for 6 months. At baseline the patients showed normal levels of vitamin E and high levels of oxLDL-Ab, vWf and TM compared to healthy subjects. In the CLE group oxLDL-Ab and vWf, but not TM levels, decreased progressively (from 472+/-287 to 264+/-199 mU/mL, p<0.0001 and from 101.1+/-7.5% to 76.7+/-18.5%; p<0.001, respectively), and vitamin E increased from 4.40+/-0.81 to 7.81+/-1.16 microg/mg of cholesterol. At the end of the study, 8 of the patients treated with CLE were randomly selected and went back to the membrane without Vitamin E for six months. They showed an significant increase in OxLDL-Ab and vWf levels and a significant reduction in tocoferol levels. In conclusion, CLE compared to cellulosic dialyzers can lower some indices of damage to LDL and endothelial cells.

Adult↗

Vitamin E-coated membrane dialyzer and beta2-microglobulin removal.

This study was designed to test the removal of beta2-microglobulin (beta2M) in a vitamin E-modified membrane. We investigated in vivo the dialyzer (Excebrane, series EE, 1.8 m2) with respect to hydraulic permeability (Kuf), maximum ultrafiltration rate (UF max), sieving coefficient (Sc), and solute clearances in hemodialysis (HD) and in soft hemodiafiltration (HDF). Kuf was 18.4 ml/h/mmHg, UF max was 75 ml/min, and Sc for beta2M was 0.45. Clearance values at 400 ml/min of Qb in HD were 258 ml/min for urea, 201 ml/min for creatinine, and 135 ml/min for phosphate. In soft HDF, clearances were slightly higher. beta2M clearance was 26 ml/min in HD and 43 ml/min in soft HDF. In conclusion, Excebrane (series EE) procures a soft HDF with an amount of substitution fluid in post dilution mode of over 60 ml/min. Remarkable small solute clearances were obtained when the blood flow was raised to 400 ml/min. A significant reduction of beta2M is demonstrated by HDF.

Antioxidants↗

Impact of blood and dialysate flow and surface on performance of new polysulfone hemodialysis dialyzers.

Optimization of hemodialysis treatment parameters and the characteristics of the dialyzer are crucial for short- and long-term outcome of end stage renal disease patients. The new high-flux membrane Helixone in the dialyzer of the FX series (Fresenius Medical Care, Germany) has interesting features, such as the relationship of membrane thickness and capillary diameter which increases middle molecule elimination by convection, as well as higher capillary packing and microondulation to improve the dialysate flow and distribution. Blood flow, dialysate flow and surface area are the main determinants of the performance of a dialyzer, however the impact of each parameter on small and middle molecule clearance in high flux dialysis has not been well explored. In order to find the best treatment condition for the new dialyzer series, we evaluated urea, creatinine, phosphate clearances and reduction rate of beta2-microglobulin in ten stable patients treated with different blood flows (effective Qb 280 and 360 ml/min), dialysate flow (Qd 300 or 500 ml/min) and dialyzer surfaces (1.4 and 2.2 m2, FX60 or FX100). KoA and Kt/V were also calculated. Blood flow, dialysate flow and surface area demonstrated a significant and independent effect on clearance of urea, creatinine and phosphate, as well as on Kt/V. Small solute clearance was stable over the treatment. In contrast to small solutes, reduction rate of beta2-microglobulin was related to increasing dialyzer surface only. The new dialyzer design of the FX series proves highly effective due to improved dialysate distribution and reduced diffusive resistance as shown by the small solute clearance. A high reduction rate of beta2-microglobulin is favored by improved fiber geometry and pore size distribution. These findings have potential long-term benefits for the patient.

Aged↗

In vitro and in vivo biocompatibility of substituted cellulose and synthetic membranes.

Regenerated cellulosic membranes are held as bioincompatible due to their high complement - and leukopenia - inducing properties. Adherence of polymorphonuclear neutrophils and monocyte purified from normal human blood to the three membranes were evaluated in an in vitro recirculation circuit in the presence or absence of fresh, autologous plasma after recirculation in an in vitro circuit using minimodules with each of the three membranes. In in vivo studies, 9 patients were treated with conventional haemodialysis for 2 weeks with each membrane and 1 week for wash-out using haemodialysers with the following surface: 1.95 m2 for benzyl-cellulose, 1.8 m2 for acetate-cellulose and low-flux polysulfone. Measurement of leukopenia, plasma C3a des Arg and elastase-alpha1 proteinase inhibitor complex levels as well as urea, creatinine, phosphate and uric acid clearances was performed. Plasma-free neutrophils adhered maximally to acetate-cellulose (65% remaining in the circulation), while there was no significant difference between low-flux polysulfone and benzyl-cellulose (80% circulating neutrophils, at 15 min, p<0.001 vs acetate cellulose). In the presence of fresh plasma, as source of complement, the differences between acetate cellulose vs polysulfone and benzyl-cellulose were even more evident, suggesting the role of complement-activated products in neutrophil adherence. A similar trend was observed for monocyte adherence with the three membranes in the absence or presence of plasma. In vivo studies showed that the nadir of leukopenia was at 15 and 30 min with acetate-cellulose (79%) and benzyl-cellulose (50%) (p<0.05 acetate- vs benzyl-cellulose) and at 15 min with polysulfone (24%) (p<0.01 vs acetate- and benzyl-cellulose). Plasma C3a des Arg levels arose to 2037 +/- 120 ng/ml, 1216 + 434 ng/ml and 46 +/- 55 ng/ml with acetate-, benzyl-cellulose and polysulfone, respectively. No pre- vs post-dialysis increase in the intracellular content of TNF-alpha was detected with any of three membranes. Clearance values of urea, creatinine and uric acid were superimposable for all the three membranes. However, benzyl cellulose had a significantly higher clearance for phosphorus (normalized for surface area) (p<0.01 vs acetate-cellulose, 0.001 vs polysulfone). These results implicate that synthetic modification of the cellulose polymer as for the benzyl-cellulose significantly reduces the in vitro adherence, delays the in vivo activation of "classic" biocompatibility parameters and notably improves the removal of inorganic phosphorus.

Aged↗

On-line urea kinetics in haemodiafiltration.

BACKGROUND: Calculation of Kt/V and assessment of nutrition have so far been dependent upon off-line urea measurements of blood or dialysate samples. Here we describe a biosensor for on-line urea measurement during haemodiafiltration. Methods. The biosensor consisted of a cartridge containing covalently linked urease placed between two conductivity cells. The biosensor was placed on the outlet line of a haemofilter in series with a dialyser in order to obtain an aliquot of plasma ultrafiltrate for on-line measurement of urea. RESULTS: Urea nitrogen concentrations were highly correlated to the difference (Delta) in conductivity measured by the two conductivity cells both in aqueous solutions (in-vitro studies, y=-6. 676+32.12x, R2=0.998, P<0.0001) and in ultrafiltrates (ex-vivo studies, y=-637+32.01x, R2=0.98, P<0.00001). Delta conductivity was highly reproducible (% variation: ).8-5.3%) and stable (maximal % variation at 150 mg/dl after 100 min. 0.9+/-0.3 vs initial values). The intradialytic plasma water urea profile was obtained in 10 haemodialysis patients. To study recirculation, the plasma water urea profile was analysed before and 3 min after stopping the dialysate flow. The pre- and post-stopped flow ratio (1.21+/-0.1, mean+/-1 SD) was superimposable to conventional blood sampling data (opposite arm venous arterial: 1.22+/-0.11) and allowed correction for recirculation. A novel approach to urea kinetic modelling was described and used to reliably project end-dialysis and post-dialysis rebound urea concentration as early as 90 min. Projected (29.2+/-10.4 g) or measured (29.8+/-10.5 g) net urea removal was highly correlated with the amount of urea collected in the total spent dialysate (29.7+/-10.6 g) (R2=0.99, R2=0.97 respectively). CONCLUSIONS: These results indicate that on-line, real-time analysis of urea kinetics may provide information on delivery of adequate dialysis in high-efficiency techniques.

Adult↗

Protein nitrogen appearance in CAPD patients: what is the best formula?

BACKGROUND: The protein equivalent of nitrogen appearance is an indirect index commonly used to assess dietary protein intake in patients on CAPD. Moreover it has been suggested that the ratio between nitrogen appearance and dietary nitrogen intake (fractional urea synthesis) can predict nitrogen balance in uraemic patients. Several formulae to directly calculate the protein equivalent of nitrogen appearance have been published. It has not been established, however, what formulae give the most appropriate estimate of protein intake and nitrogen appearance. STUDY DESIGN: Nitrogen balance studies were carried out in seven stable patients on CAPD. All of the patients were receiving a diet whose protein content (1.2 g/kg/body wt/day) and calorie content (35 kcal/kg/body wt/day) were rigorously controlled. Six formulae for calculating protein equivalent of nitrogen appearance and nitrogen appearance were tested and the agreement of the estimating formulae was evaluated by means of the Bland and Altman method. RESULT: Net nitrogen balance was 1.68 +/- 0.9 g/N day, protein intake (g/day) 81 +/- 19, protein intake (g/kg) 1.05 +/- 0.17. Differences in protein equivalent of nitrogen appearance of up to about 20% were found. The smallest differences between protein equivalent of nitrogen appearance and protein intake were obtained by the formulae of Bergstrom (1 +/- 7 g, limits of agreement -12 and +15 g) and Blumenkrantz (-2 +/- 5 g, limits of agreement -11 and +7 g). The formula of Bergstrom most closely estimated nitrogen appearance (-0.35 +/- 0.89 g). Using such formula, the fractional urea synthesis was 54 +/- 12%, giving evidence of positive nitrogen balances. CONCLUSION: For the routine monitoring of protein equivalent of nitrogen appearance in CAPD patients, we recommend Bergstrom's formula with the determination of dialysate protein losses.

Blood Urea Nitrogen↗

Biochemical aspects and clinical perspectives of continuous urea monitoring in plasma ultrafiltrate. Preliminary results of a multicenter study.

We tested a new biosensor for urea monitoring in the ultrafiltrate during PFD in a group of 5 hemodialyzed stable patients. The inspection of the UF-urea profile reflects the dynamical changes of the plasma urea concentration during diffusive dialysis and allows the fitting of the main mathematical models of urea kinetics. The biosensor efficiency was 98.4% on average (SD: 1.5%) at Uf fluxes varying from 45 to 55 ml/min (mean: 51 ml/min; SD: 3.2) and at Uf-urea concentrations varying from 23 to 165 mg/dl. The mean difference between Uf-urea determined by the laboratory method and Uf-urea assayed by the biosensor was -1.07 mg/dl and the 95% confidence interval ranged from -2.01 to 0.13 mg/dl. The mean difference between laboratory plasma urea and Uf-urea from the biosensor was on average -1.9 mg/dl and the estimated limits of agreement with a confidence of 95% were -3.16 and 0.64 mg/dl. Comparison between kinetic models and experimental profiles of plasma urea decrease, evaluations of recirculation and post-dialytic rebound, the role of Kt/V on-line during dialysis were the preliminary clinical applications of this biosensor.

Aged↗

Bioelectrical impedance and hemodialysis.

Bioimpedance is a simple and non-invasive method of assessing body fluid composition. The aim of our study was to evaluate the reilability of impedance: a) to measure urea distribution volume considered to be coextensive with total body water (TBW); b) to assess the changes in body fluid compartments before and after dialysis; c) to predict hypotensive episodes. In twelve hemodialysis patients, TBW measured by bioelectrical impedance analysis (BIA) before a dialysis session was significantly correlated with the urea distribution volume estimated by dialysis direct quantification (r = 0.64, p < 0.05) and with TBW calculated by the Watson equation (r = 0.65, p < 0.05). Anthropometric values were, on average, 4.8% higher. TBW measured by BIA at the end of treatment overestimated fluid losses induced by ultrafiltration by 14% to 70%, while TBW 6 h after dialysis reflected the weight losses. On line BIA during hemodialysis has a very low positive predictive value (41.6%) and poor sensitivity (66%) for the prediction of hypotension. In conclusion, BIA is helpful in assessing the urea distribution volume but is not reliable for assessing acute fluid changes nor for predicting hypotensive episodes related to hemodialysis.

Adult↗

Computerized management of peritoneal dialysis.

The importance of the evaluation of dialytic adequacy is well known in peritoneal dialysis. It is necessary to be able to quantify and individualize the substitution treatment. In 15 patients we compared five quantitative approaches by using original software: Teehan's dialysis index (DI); Diaz-Buxo's liters/week (LW); Keshaviah's the quantity of dialysis prescribed (wKt/V); and Boen and Twardowski's weekly creatinine clearance (WC). All patients were treated by continuous ambulatory peritoneal dialysis (CAPD) according to the peritoneal equilibration test (PET). Peritoneal solute clearances for urea, creatinine, uric acid, and phosphorus were adequate, but there was disagreement between adequacy indexes. According to the DI, 40% of our patients were underdialyzed, 33% were adequate, and 27% received excessive dialytic dose, while according to LW and wKt/V, about 50% were adequate, 10% underdialyzed, and 40% received excessive doses. According to WC, 74% were overdialyzed and 26% were adequate. In two patients only (13%) all the indexes indicated underdialysis. We think that the DI is too severe an adequacy index, probably because residual renal clearances have a great weight in the formula, while WC may lead to an overestimate of the actual dose of therapy in patients with significant residual renal clearance. Prospective, randomized and clinical studies are needed to better assess the optimal index for individualization of targeted peritoneal dialysis prescription.

Creatinine↗

Plasma profiles and dialysis kinetics of oxalate in patients receiving hemodialysis.

Regular dialysis treatment (RDT) does not obviate hyperoxalemia of chronic renal failure (CRF). However, there is emerging evidence suggesting that current dialysis prescription is not always associated to progressive oxalate accumulation. In view of the controversy still concerning this issue, we have investigated on plasma profiles and dialysis kinetics of oxalate in patients on RDT. Oxalate was determined by ion chromatography on serum ultrafiltrates and on the whole dialyzate in 23 stable patients on RDT for end-stage renal failure unrelated to primary hyperoxaluria. Nine patients were on traditional hemodialysis (HD) and 14 on soft hemodiafiltration (HDF). Dialysis prescription was set so as to obtain similar KT/V of urea. Mean dialyzer clearance of oxalate (KdOx) was calculated by standard procedures and was compared to urea (KdUrea) and creatinine (KdCr) clearances. Oxalate removal was measured on the whole spent dialyzate. Distribution volume of oxalate (VOx) was estimated by assuming a single-pool model and was used to estimate the oxalate appearance rate (OxAR). Plasma profiles showed that dialysis patients were virtually always hyperoxalemic. However, the threshold of supersaturation for calcium oxalate was exceeded in only 13 of 138 (9.4%) assayed ultrafiltrates, 13% on HD and 7.1% on HDF. Dialysis reduced plasma oxalate by more than 60%. There was a postdialysis oxalate rebound averaging 9.6% at 30 min from the end of dialysis. Plasma oxalate predialysis was independent of sex, age and time on dialysis. KdOx was mildly higher on HDF than on HD, and was lower than both KdUrea and KdCr, irrespective of the dialysis technique.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Effect of hemodialysis and hemodiafiltration on uremic neuropathy.

This study was undertaken to compare the effect of 1 year hemodialysis (HD) or hemodiafiltration (HDF) treatment on peripheral neuropathy. Thus 21 of 42 patients on chronic HD (1-1.3 m2 cuprophane dialyzer, Qb 300 ml/min) were switched to HDF (1.3 m2 polysulfone dialyzer, Qb 400 ml/min, substitution volume 9-13 liters, ultrafiltration rate 60-70 ml/min), while the remaining patients were considered as a control group. Treatment time was scheduled both in HD and HDF to maintain adequate BUN levels in relation to protein catabolic rate. However, HDF provided a significantly greater weekly inulin (MW 5,000) clearance than HD (5.8 +/- 1.2 vs. 1.6 +/- 0.2 ml/min; p less than 0.001). HD and HDF groups were comparable for age, time on dialysis and starting electroneurographic parameters, which were on average within the normal range. After 1 year follow-up, creatinine, hematocrit, calcium, phosphate, PTH, BUN, protein catabolic rate and residual GFR were comparable in the two groups, whereas beta 2-microglobulin was significantly reduced in HDF patients (29 +/- 6.7 vs. 38.8 +/- 13.9 mg/l in HD patients, p less than 0.01). During the 1-year treatment, electroneurographic parameters did not change in HDF patients, whereas a significant decrease of ulnar motor nerve conduction velocity, ulnar muscle action potential amplitudes, median sensory nerve conduction velocity and peroneal muscle action potential amplitudes was detected in HD patients. We conclude that HDF might prevent the worsening of the electroneurographic indices occurring during chronic HD treatment, as it provides a more effective removal of middle and larger molecules than HD. The use of a more biocompatible membrane in HDF might further contribute to this favorable effect on uremic neuropathy.

Adult↗

How to improve dialysis adequacy in patients with vascular access problems.

Blood flow rate is a critical factor in the achievement of an adequate dialysis dose. The aim of this review is to evaluate the possibility of optimizing dialysis dose in terms of Kt/V in patients with reduced vascular access (VA) flow rate, considering effective blood flow (Qb eff), recirculation, access flow and hemodialyzer. In patients where the achievement of adequate blood flow rates are difficult to obtain and no surgical revision is necessary, to avoid under dialysis the increase in the treatment time should be the first choice solution. If such a solution is difficult for various reasons, a forced partial blood flow recirculation, especially in central venous catheters (CVCs) with reversed lines can be useful, on condition that the dialysis session is prolonged. The possibility of increasing the efficiency of dialysis through an increase in filter clearance has to be considered. Monitoring arterial pre-pump pressure (P asp) and optimizing ratio P asp/Qb eff during hemodialysis (HD) is one possible solution to improve blood flow rates, but it is necessary to educate and involve the staff. Recent developments in a new class of highly effective hemodialyzer due to dialysate distribution, has opened up interesting opportunities in terms of dialysis adequacy in patients with reduced VA flow rate.

Arteriovenous Shunt, Surgical↗

Catheter lock solutions: it's time for a change.

In recent years, the number of patients on hemodialysis (HD) with central vascular catheters (CVCs) has grown. However, CVC use is often associated with an important risk for catheter related bloodstream infections (CR-BI) and inadequate dialysis due to flow problems. In this study, we reviewed alternative solutions to heparin for locking HD CVCs. Several experiences have demonstrated that trisodium citrate (TSC) (30-47%), citrate (4%) and taurolidine (1.35%) solutions are effective and safe for the prevention of CRBI, while heparin stimulates biofilm formation. High citrate (47%) concentrations can also provide significant advantages in reducing catheter clotting, but controlled studies with larger populations are necessary to confirm and to extend the use of such solutions in clinical practice. Side effects with high sodium citrate concentrations have been reported only immediately after locking, the symptoms are probably caused by a temporary drop in ionized calcium and magnesium, but it is evident that these solutions should only be used by skilled and authorized personnel, with a rigorous protocol.

Anti-Infective Agents↗

[New dialysis therapy modalities: what role do they play in the hemodialysis patient's outcome?].

Many studies have been devoted to investigating new techniques and new dialysis strategies aimed at achieving adequate removal of "uremic toxins". Conversely, few studies focus on the effect of different dialysis techniques on long-term outcome, including large series and with adequate follow-up. Dialysis dose, membrane biocompatibility and permeability, convective techniques, and the number and duration of dialysis sessions have all been considered as potentially related to patient outcome. The available data from the literature clearly show a significant relationship between the urea kinetic model based dialysis delivered and long-term patient outcome. A significant positive correlation between survival and Kt/V up to 1.3 per session in patients treated three times a week with standard low flux cellulosic dialyzers has been shown. Many studies have shown an effect of high flux membranes on the appearance of symptoms related to dialysis amyloidosis. It is likely that such an effect is further enhanced by convective or mixed techniques. The role of these techniques in patient survival is suggested by some studies, but should be confirmed in larger series. The use of techniques suitable for ultra-pure dialysis fluids are mandatory whenever high permeability membranes are used. Treatment schedules which include long dialysis sessions or an increased number of sessions such as daily dialysis, seem to be beneficial for the control of hypertension or hyperphosphatemia. However, their role on patient survival has not yet been clearly assessed. Together with the choice of the best strategy, great attention should be paid to other factors known to be related to patient outcome, such as early patient referral, and the type and efficiency of vascular access.

Amyloidosis↗