PubMed Health⌕ Search

Biomedical subjects

S McNeeley

Publications and source records attributed to S McNeeley.

9 recordsLinked to original sources

Elongated beamlets: a simple technique for segment and MU reduction for sMLC IMRT delivery on accelerators utilizing 5 mm leaf widths.

The focus of this work is to demonstrate the effects of using an elongated beamlet to achieve similar dose conformity as achieved with a square beamlet while reducing the number of segments and subsequent MU required. A series of 10 patients were planned for IMRT delivery to the prostate using minimum beamlet sizes of 5x5 mm2 (default scheme), 10x5 mm2 with the short axis parallel to the prostate-rectum interface (scheme 1), and 10x5 mm2 with the short axis perpendicular to the prostate-rectum interface (scheme 2). All other parameters between plans were left unchanged. Plans were appropriately normalized and evaluated for R65, R40, conformity index, total number of segments and MU. All plans were generated using the Corvus inverse planning system. The average number of segments in this study decreased by approximately 49% for both schemes 1 and 2. The subsequent number of MU required decreased by approximately 34.6%. The resultant modified modulation scaling factor (MSFmod) decreased by approximately 34.3%. Additionally, we found that each isodose distribution using scheme 2 would still meet our clinical acceptance criteria with no visible degradation in the dose distribution as compared with the default scheme. In conclusion, we have demonstrated that it is possible to achieve similar results as those obtained using a 5x5 mm2 beamlet with respect to target coverage and critical structure sparing by using strategically oriented elongated beamlets. This technique directly translates to a decreased MSF(mod) allowing for decreased leakage dose to the patient, a decreased risk of exceeding secondary shielding limits in pre-existing vaults, and shorter treatment times.

Algorithms↗

Dosimetric verification of IMRT treatment planning using Monte Carlo simulations for prostate cancer.

The purpose of this work is to investigate the accuracy of dose calculation of a commercial treatment planning system (Corvus, Normos Corp., Sewickley, PA). In this study, 30 prostate intensity-modulated radiotherapy (IMRT) treatment plans from the commercial treatment planning system were recalculated using the Monte Carlo method. Dose-volume histograms and isodose distributions were compared. Other quantities such as minimum dose to the target (D(min)), the dose received by 98% of the target volume (D98), dose at the isocentre (D(iso)), mean target dose (D(mean)) and the maximum critical structure dose (D(max)) were also evaluated based on our clinical criteria. For coplanar plans, the dose differences between Monte Carlo and the commercial treatment planning system with and without heterogeneity correction were not significant. The differences in the isocentre dose between the commercial treatment planning system and Monte Carlo simulations were less than 3% for all coplanar cases. The differences on D98 were less than 2% on average. The differences in the mean dose to the target between the commercial system and Monte Carlo results were within 3%. The differences in the maximum bladder dose were within 3% for most cases. The maximum dose differences for the rectum were less than 4% for all the cases. For non-coplanar plans, the difference in the minimum target dose between the treatment planning system and Monte Carlo calculations was up to 9% if the heterogeneity correction was not applied in Corvus. This was caused by the excessive attenuation of the non-coplanar beams by the femurs. When the heterogeneity correction was applied in Corvus, the differences were reduced significantly. These results suggest that heterogeneity correction should be used in dose calculation for prostate cancer with non-coplanar beam arrangements.

Computer Simulation↗

Daily target localization for prostate patients based on 3D image correlation.

There are several localization techniques that have been used for prostate treatment. Recently, the potential use of a variety of CT-based equipment in the treatment room has been discussed. The goal of our study was to develop an automated procedure for daily treatment table shift calculation based on two CT data sets: simulation CT data and localization CT data. The method suggested in this study is a 3D image cross-correlation of small regions of interest (ROI) within the two data sets. The relative position of the two ROIs with respect to each other is determined by the maximum value of the normalized cross-correlation function, calculated for all possible relative locations of the two ROIs. After the best match is found the shifts are given by the vector connecting the treatment isocentre and the planning isocentre (both determined by the radio opaque fiducial markers on the patient's skin). The results have been compared with shifts calculated through manual fusion. The shift differences, averaged over 17 statistically independent shift calculations, are less then 1 mm in the lateral and longitudinal directions, and about 1 mm in the AP direction. The impact of image noise on the performance of the algorithm has been tested. The results show that the algorithm accurately adjusts for target positional changes even with Gaussian noise levels as high as 20% inserted.

Algorithms↗

Ultrasound-based stereotactic guidance in prostate cancer--quantification of organ motion and set-up errors in external beam radiation therapy.

OBJECTIVE: A mobile transabdominal ultrasound-based targeting system (BAT(R)) has been developed which can stereotactically localize the position of the prostate each treatment day and directly integrate this information into the treatment planning system. Daily target verification facilitates a marked reduction in planning treatment margins by correcting potential organ-motion and set-up errors. Previous studies have been performed to establish the precision of ultrasound localization. This report quantifies the magnitude of the patient isocenter shift parameters encountered during clinical implementation of this system. MATERIAL AND METHODS: After five weeks of conformal external beam radiation therapy, 54 patients underwent a second CT simulation. Prostate-only fields based on this scan were created with no PTV margin beyond the CTV. For each of the final conedown treatments (2-4 fractions), patients underwent ultrasound-based stereotactic prostate localization at the treatment machine. The portable system, which electronically imports the CT simulation target-contour and isocenter information, is situated adjacent to the treatment couch. Transverse and sagittal suprapubic ultrasound images are captured, and the system electronically couples this data to the baseline isocenter. The CT contours are maneuvered in three dimensions by a touch-screen menu to visually overlay the ultrasound images. The system then displays the three-dimensional (3D) couch shifts required to produce field alignment. RESULTS: One hundred and eighty-nine daily ultrasound prostate position shifts were recorded for 54 patients. The isocenter field misalignment between the baseline CT and ultrasound ranged from -26.8 to 33.8 mm in the anterior/posterior (A/P) dimension, -10.2 to 30.9 mm in the lateral dimension, and -24.6 to 9.0 mm in the superior/inferior (S/I) dimension. The corresponding directed average disagreements were -3.0 mm (SD 8.3 mm) A/P, 1.86 mm (SD 5.7 mm) lateral, and -2.6 mm (SD 6.5 mm) S/I. The magnitudes of undirected misalignments were frequently larger than 5 mm (51% of A/P, 31% of lateral, and 35% of superior measurements) and oftentimes larger than 10 mm (21% of A/P, 7% of lateral, and 12% of superior measurements). CONCLUSIONS: Organ motion and set-up uncertainties limit optimization of 3D treatment planning by expanding the width of PTV margins required to ensure target coverage. Transabdominal ultrasound-based stereotactic guidance is a safe and direct method for correcting patient positioning. Our experience with the BAT system in a large cohort of prostate cancer patients revealed that substantial daily isocenter corrections were encountered in a large percentage of cases. This data would suggest that daily clinical isocenter misalignments are greater than would be expected from published data on organ motion and set-up variations encountered in the study setting.

Cohort Studies↗

Ultrasound-based stereotactic guidance of precision conformal external beam radiation therapy in clinically localized prostate cancer.

OBJECTIVES: Use of external beam radiation fields that conform to the shape of the target improves biochemical control in prostate cancer by facilitating dose escalation through increased sparing of normal tissue. By correcting potential organ motion and setup errors, ultrasound-directed stereotactic localization is a method that may improve the accuracy and effectiveness of current conformal technology. The purpose of this study was to quantify the precision of the transabdominal ultrasound-based approach using computed tomography (CT) as a standard. METHODS: Thirty-five consecutive men participated in a prospective comparison of daily CT and ultrasound-guided localization at Fox Chase Cancer Center. Daily CT prostate localization was completed before the delivery of each final boost field. In the CT simulation suite, transabdominal ultrasound-based stereotactic localization was also performed. The main outcome measure was a three-dimensional comparison of prostate position as determined by CT versus ultrasound. RESULTS: Sixty-nine daily CT and ultrasound prostate position shifts were recorded for 35 patients. The magnitude of difference between the CT and ultrasound localization ranged from 0 to 7.0 mm in the anterior/posterior, 0 to 6.4 mm in the lateral, and 0 to 6.7 mm in the superior/inferior dimension. The corresponding directed average disagreements were extremely small: anterior/posterior, -0.09 +/- 2.8 mm SD; lateral, -0.16 +/- 2.4 mm SD; and superior/inferior, -0.03 +/- 2.3 mm SD). Analysis of the paired CT-ultrasound shifts revealed a high correlation between the two modalities in all three dimensions (anterior/ posterior r = 0.88; lateral r = 0.91; and superior/inferior r = 0.87). CONCLUSIONS: Ultrasound-directed stereotactic localization is safe and as accurate as CT scanning in targeting the prostate for conformal external beam radiation therapy. The application of this technology to current conformal techniques will allow the reduction of treatment margins in all dimensions. This should diminish treatment-related morbidity and facilitate further dose escalation, resulting in improved cancer control.

Follow-Up Studies↗

A comparison of daily CT localization to a daily ultrasound-based system in prostate cancer.

PURPOSE: Daily CT localization has been demonstrated to be a precise method of correcting radiation field placement by reducing setup and organ motion variations to facilitate dose escalation in prostate carcinoma. The purpose of this study was to evaluate the feasibility and accuracy of daily ultrasound-guided localization utilizing daily CT as a standard. The relatively simple computer-assisted ultrasound-based system is designed to be an efficient means of achieving daily accuracy. METHODS AND MATERIALS: After five weeks of conformal external beam radiation therapy, 23 patients underwent a second CT simulation. Prostate-only fields based on this scan were created with no PTV margin. On each of the final conedown treatment days, a repeat CT simulation and isocenter comparison was performed. Ten of the above patients also underwent prostate localization with a newly developed ultrasound-based system (BAT) that is designed to facilitate patient positioning at the treatment machine. The portable system, which electronically imports the CT simulation target contours and isocenter, is situated adjacent to the treatment couch. Transverse and sagittal suprapubic ultrasound images are captured, and the system overlays the corresponding CT contours relative to the machine isocenter. The CT contours are maneuvered in three dimensions by a touch screen menu to match the ultrasound images. The system then displays the 3-D couch shifts required to produce field alignment. RESULTS: The BAT ultrasound system produced good quality images with minimal operator training required. The localization process was completed in less than 5 min. The absolute magnitude difference between CT and ultrasound was small (A/P range 0 to 5.9 mm, mean 3 mm +/- 1.8; Lat. range 0 to 7.9 mm, mean 2.4 mm +/- 1.8; S/I range 0 to 9 mm, mean 4.6 mm +/- 2.8). Analysis confirmed a significant correlation of isocenter shifts (A/P r = 0.66, p < 0.0001; Lat. r = 0.58, p < 0.003; S/I r = 0.78, p < 0.0001) in all dimensions, and linear regression confirmed the equivalence of the two modalities. CONCLUSIONS: Daily CT localization is a precise method to improve daily target localization in prostate carcinoma. However, it requires significant human and technical resources that limit its widespread applicability. Conversely, localization with the BAT ultrasound system is simple and expeditious by virtue of its ability to image the prostate at the treatment machine in the treatment position. Our initial evaluation revealed ultrasound targeting to be functionally equivalent to CT. This ultrasound technology is promising and warrants further investigation in more patients and at other anatomical sites.

Feasibility Studies↗

Use of the prone position in radiation treatment for women with early stage breast cancer.

PURPOSE: The prone position has been advocated for women with large pendulous breasts undergoing breast-conserving treatment with radiation therapy. However, there is no information in the literature regarding the coverage of the target volume with this technique. The purpose of this study was to evaluate the effectiveness of the prone treatment position in including at least the biopsy cavity with a 2-cm margin. METHODS AND MATERIALS: Eleven consecutive patients who underwent CT simulation in the prone position were included in this study. Patients underwent CT simulation in the prone position using a flat platform containing an aperture for the breast to hang through in a dependent fashion. CT slices were 5-mm thick taken at 3-mm intervals. The biopsy cavity was localized and outlined on sequential CT images using the surgical clips (when present) as well as the residual seroma. A 2-cm margin was included around the biopsy cavity to define the minimal target volume (mTV). Lateral fields were used for treatment planning. The beam arrangements were considered adequate if the mTV was totally included in the lateral fields. RESULTS: Median age of the patient population was 55 years. Bra sizes ranged from 36A-44DD. The majority of patients had mammographically detected T1 lesions. Median volume of the biopsy cavity was 48 cm3. Five of 11 (45%) patients underwent reexcision of the biopsy cavity, and 6 of 11 (55%) had surgical clips placed in the biopsy cavity. Overall, 8 of 11 (73%) patients did not have the entire mTV included in the lateral opposed tangential fields in the prone position. This was especially true in patients whose biopsy cavity extended down to the chest wall. There were no other clinical factors that could predict for the adequacy of coverage in the prone position. CONCLUSION: Special attention must be paid to the location of the surgical clips to determine the proximity of the biopsy cavity to the chest wall, or CT simulation should be performed to determine the exact location of the biopsy cavity prior to selecting patients with large pendulous breasts for treatment in the prone position.

Adult↗

Effects of chlorinated hydrocarbon on plasma alpha-lipoprotein cholesterol in rats.

Ten chlorinated hydrocarbons (tetradifon, Chlorobenzilate, Kepone, lindane, Kelthane, toxaphene, dieldrin, hexachlorobenzene, dienochlor, and Aroclor 1254; see below) were evaluated in rats to assess agents which might selectively elevate high-density lipoprotein cholesterol (C-HDL). Single, nontoxic doses of Aroclor, dieldrin, and Kepone elevated C-HDL at day 7 (31%, 26%, and 24%, respectively, p less than 0.05). The C-HDL elevations were maintained at days 21 and 60 (28% and 31%, p less than 0.01) in the Aroclor group, while C-HDL returned to baseline in the dieldrin and Kepone groups. Liver function tests were unchanged from control, suggesting that the changes in C-HDL were not the consequence of hepatotoxicity. The hepatic microsomal cytochrome P-450 content of animals receiving Aroclor, dieldrin, and Kepone was 67%, 56%, and 44% higher than control values (p less than 0.02), indicating probable hepatic enzyme induction. If HDL (an antiatherogenic lipoprotein) is also selectively elevated by chlorinated hydrocarbons in man, then analogues might potentially be developed as antiatherogenic pharmacologic agents. Alternatively, the implications of man's exposure to halogenated hydrocarbons may be better understood.

Cholesterol↗