PubMed Health⌕ Search

Biomedical subjects

S Minagi

Publications and source records attributed to S Minagi.

At least 19 recordsLinked to original sources

Enhanced vertical alveolar bone augmentation by recombinant human bone morphogenetic protein-2 with a carrier in rats.

This study aimed to evaluate the effect of recombinant human bone morphogenetic protein-2 (rhBMP-2) on vertical bone regeneration of edentulous ridge. Bilateral upper first and second molars of 8-week-old Wistar rats were extracted and the ridges were allowed to heal for 3 weeks. Compressed poly(lactic-co-glycolic acid) copolymer/gelatin sponge (PGS) was used as a carrier of rhBMP-2. PGS alone (control group) or PGS with 5 mug rhBMP-2 (test group) was implanted at the top part of alveolar ridge. The sham group received no implantation. The rats were killed at 1, 2, 4, 8 and 12 weeks after implantation and examined histologically and histomorphometrically. In the test group, significant bone augmentation was evident on the alveolar ridge throughout the experimental period. Histomorphometric analysis revealed greater tissue volume and height of alveolar bone in the test group compared with the control and sham groups (P < 0.05) from 4 weeks onward and the augmented tissues (5 mm3 in tissue volume and 1.5 mm in bone height) were maintained until 12 weeks. Osteoblast surface increased at 2 and 4 weeks and osteoid thickness reached a peak (25 microm) at 2 weeks. Dynamic variables, which represented calcification, were higher in the test group than the control and sham groups at 4 and 8 weeks (P < 0.05). These results suggest that use of rhBMP-2/PGS may achieve vertical bone augmentation, and stabilizes denture prosthesis or makes up for inadequate bone mass for implant prosthesis.

Alveolar Process↗

Is the posterior belly of the digastric muscle palpable? A qualitative systematic review of the literature.

Palpation of the posterior belly of the digastric muscle in the postmandibular region is included in many study protocols and examination schemes of the masticatory system. The aim of the present investigation was to systematically search the dental/medical literature to find evidence for the palpability of this muscle. In August 2004, a systematic search was carried out using different electronic databases (PubMed, Cochrane Library, Web of Science, Japana Centra Revuo Medicina, MedPilot, Latin American and Caribbean Health Sciences, and three on-line databases of dental journals not listed currently in Medline), supplemented by manual search in the Austrian journal Stomatologie. Additional manual searches were carried out in the Journal of Orofacial Pain and Journal of Dental Research to identify pertinent abstracts of scientific congresses. One relevant hit was found in the Japanese database. The manual search showed one pertinent congress abstract. In both publications, the authors concluded that due to anatomical reasons the posterior belly of the digastric muscle was not palpable. Hence, evidence is lacking that the posterior digastric muscle is accessible to palpation. Because the postmandibular region is usually tender upon palpation, a high incidence of positive findings can be expected even among healthy subjects. This may lead to wrong clinical judgments, possibly provoking unnecessary diagnostic and therapeutic measures.

Humans↗

Magnetic resonance imaging analysis on the relationship between anterior disc displacement and balancing-side occlusal contact.

The purpose of this study was to evaluate the relationship between balancing-side occlusal contact patterns and the prevalence of the internal derangement of the temporomandibular joint (TMJ). Forty-one patients were used for the magnetic resonance image (MRI) analysis of TMJ and occlusal examination. Balancing-side occlusal contact patterns observed during mandibular lateral excursive movements were classified into the three following categories: group A, simultaneous balancing-side contact, group B, balancing-side contact (with clenching only) and Group C, no balancing-side contact (with or without clenching). By the occlusal examination of 57 sides, 31.6% showed group A, 8.8% showed group B and 59.6% showed group C contact. Group A could not be observed in the patient group with normal disc position. In the disc displacement group, the prevalence of group A, group B and group C were 40.9, 6.8 and 52.3%, respectively. The higher prevalence of simultaneous balancing-side contact was revealed to be associated with articular disc dislocation.

Adolescent↗

Visual observation of the dynamic flow of elastomer rubber impression material between the impression tray and oral mucosa while seating the impression tray.

The purpose of this study was to inspect visually, the dynamics of the impression flow at seating of the impression tray. The effects of the relief and the escape hole of the impression tray on the impression flow were also examined. Three types of the transparent impression tray (flat tray, relief tray and escape hole tray) were prepared. Transparent silicone polymer was put on the impression tray surface. Four drops of the dark blue silicone impression material was injected into the transparent silicone polymer on the impression tray. The impression tray was seated on the model of the denture-supporting mucosa. The movement of the four drops caused by the impression flow was visually recorded with the video camera and examined. The result for the flat tray showed that the impression material moved from inside to the outside. It was also shown that the speed of the moved impression material increased as the seating of the impression tray advanced. The results for the relief tray and the escape hole tray showed the effect of the relief and the escape hole prepared to the impression tray on the speed and the direction of the flow of the impression material.

Dental Impression Materials↗

Finite element analysis of the effect of the bucco-lingual position of artificial posterior teeth under occlusal force on the denture supporting bone of the edentulous patient.

To improve the quality of the complete denture prosthesis, the bucco-lingual position of the artificial posterior teeth must be determined with consideration of the shape of the maxillary and mandibular residual ridge and the relationship between them. The arrangement of posterior artificial teeth should be considered not only for the denture stability but also for the avoidance of high pressure on the supporting structures. A two-dimensional finite element method program to investigate the statics for the contour of the complete denture and the residual ridge was developed. With this program, the effect of the bucco-lingual position of the artificial posterior teeth under occlusal force on the denture supporting bone could be investigated.

Bite Force↗

Galvanic skin response of oral cancer patients during speech.

Severe speech difficulty is often caused after surgery of an oral cancer. Prosthetic treatment with a removable obturator prosthesis is generally provided for such patients. Although some speech ability is recovered with prosthetic treatment, patients sometimes complain of continued dissatisfaction with their speech. However, it is difficult to evaluate the dissatisfaction. Therefore, a new method for evaluation is desirable. In this study, such a new method using the galvanic skin response as the index for the dissatisfaction of the patient was developed, and its objectivity was investigated. Eleven patients with maxillary bone defects were selected. Prior to the evaluation, improvement of speech with the removable prosthesis was confirmed using the speech intelligibility test and the visual analogue scale. The electrical resistant value at pronunciation was measured with the measuring system composed with the apparatus (galvanic skin response (GSR) measuring apparatus), the personal computer program. The changes for the electrical resistant value after pronunciation were evaluated by calculating the decrease ratio at pronunciation [(the mean electrical resistance before pronunciation - the mean electrical resistance after pronunciation)/the mean electrical resistance before pronunciation]. This decrease ratio at pronunciation was defined as the index of the speech dissatisfaction of the subject. The mean values for the decrease ratio with prosthesis were significantly smaller than the values without prosthesis (P < 0.05). From the results of this study, it is suggested that the measurement of the electrical resistance change of the skin during speech could be a new method for evaluating the speech dissatisfaction of the post-oral-cancer patient.

Female↗

Plasma treatment increased shear bond strength between heat cured acrylic resin and self-curing acrylic resin.

Self-curing acrylic resin is generally used for the repair of a fractured denture base. However, re-fracture of the repaired denture base resin often occurs because of poor bonding strength between the base resin and self-curing repair resin. The effect of plasma treatment on the shear bond strength between heat cured acrylic resin and the self-cured acrylic was examined. It was revealed that plasma irradiation is effective in increasing the shear bond strength. Plasma irradiation does not cause environmental pollution, as it does not require chemicals. It is a useful method to increase adhesive strength between heat cured acrylic resin and self-curing acrylic resin.

Acrylic Resins↗

Histopathological changes in the tissues under a denture base in experimental osteoporosis with a non-pressure covering or bearing continuous pressure.

In this study, the experimental denture base on the hard palate of the molar region of osteoporotic rats was designed to cover without any mechanical pressure or to load continuous pressure (0.5, 1.5 or 3.4 kPa). Experimental osteoporosis was induced by ovariectomy and feeding on a low calcium diet. Histopathological changes induced by non-pressure covering or continuous pressure in the tissues under the experimental denture bases were examined. Regarding the histological changes induced by continuous pressure, this was evaluated in relation to the time course of the intensity of the continuous pressure. In the tissues under the denture base in osteoporotic condition with non-pressure covering, no histopathological changes caused by non-pressure covering were observed except for a transient slight proliferative reaction in the epithelial ridge. The following histopathological changes were observed in the tissues under the denture base in the osteoporotic condition bearing continuous pressure; (i) bone resorption was induced on the periosteal surface (Ps) in the osteoporotic-3.4 kPa group, and on the pressure side of the endocortical surface (p-Ec) in the osteoporotic-1.5 and -3.4 kPa group, (ii) the appearance of osteoclasts on the p-Ec in the osteoporotic-3.4 kPa group was earlier than that on the Ps in a same group, (iii) bone resorption on the pressure side of the Ec in the osteoporotic-3.4 kPa group manifested at the earlier stage than that in the osteoporotic-1.5 kPa group, (iv) bone formation following bone resorption on the p-Ec was observed more markedly than that on the Ps and (v) histopathological changes in the tissues under the denture base in experimental osteoporosis bearing continuous pressure had an intimate relationship with the initial intensity and the time course of continuous pressure.

Animals↗

Palpation of the lateral pterygoid region in TMD--where is the evidence?

OBJECTIVE: Palpation of the lower head of the lateral pterygoid muscle is included in many study protocols and examination schemes of the masticatory system. The aim of this investigation was to search the medical/dental literature to find evidence for the validity and reliability of this diagnostic procedure. METHODS: A systematic search was carried out using different electronic databases (Medline Ovid, PubMed, Cochrane Library, Embase, Current Contents Connect, Science Citation Index, Web of Science, Japana Centra Revuo Medicina), supplemented by handsearch in selected journals and by examination of the bibliographies of the identified articles. RESULTS VALIDITY: As far as the palpability of the inferior head of the lateral pterygoid muscle is concerned, five publications representing four studies could be identified. According to these investigations, the lateral pterygoid muscle is practically inaccessible for intraoral palpation due to topographical and anatomical reasons. Other anatomical structures, such as the superficial head of the medial pterygoid muscle, may be palpated instead in this region. Reliability: Determination of the palpability of the lateral pterygoid muscle is characterized by poor interexaminer agreement. Studies investigating the presence of pain in response to palpation of the lateral pterygoid area revealed a moderate intra- and interindividual reliability. Because of the tenderness of the lateral pterygoid region even among healthy subjects, positive findings may lead to wrong conclusions with regard to the need of treatment. CONCLUSIONS: Considering the lack of validity and reliability associated with the palpation of the lateral pterygoid area, this diagnostic procedure should be discarded.

Databases as Topic↗

Maintenance of condylar position using an occlusal splint after mechanical vibrating-traction of the TMJ.

Although adequate relief of excess mechanical loading to the joint has been accepted as one of the important treatment concepts in the orthopaedic field, a treatment method for the temporomandibular joint (TMJ) to relieve excess mechanical loading has not yet been established. This study aimed to clarify the effect of an occlusal splint on the maintenance of the distracted condylar position achieved by vibrating-traction method. Vibrating dynamic traction force was applied for 5 min to the right TMJ using vibrating-traction apparatus. A flat stabilization splint was adjusted to keep the mandibular position and the condylar displacement was evaluated for 6 h after the dynamic traction procedure. Mean vertical displacement of the mandibular right first molar immediately after the vibrating-traction for the six subjects was 156 microm (ranging from 141 to 179 microm). The calculated mean condylar displacement immediately after the traction was 480 mum and could be kept to be 381 mum even after 6 h by wearing the flat stabilization splint. From the results of this study, it was revealed that the mechanically tracted condylar position could be maintained by a flat occlusal splint. It was suggested that the vibrating-traction method followed by the provision of occlusal support might have a possibility to work as a mechanical relieving procedure for the TMJ.

Adult↗

Effect of a thick palatal appliance on muscular symptoms in craniomandibular disorders: a preliminary study.

Several treatment modalities for myofascial pain dysfunction syndrome (MPD) are being used at present. However, from the standpoint of patients' quality of life, it would be reasonable to seek a more effective treatment modality. This study aimed to show clinical data of a preliminary study regarding the effect of a thick palatal appliance, designed to fill the palatal concavity with a thick resin base, on muscular symptoms in eighteen MPD patients. Shown here are the clinical results of two volunteer patients using palatal appliances of two different thicknesses. In this study, MPD patents were divided into the three following groups: 1. no-treatment group; 2. thick palatal appliance group; and 3. medication group. Based on the results of this study, it was suggested that the thick palatal appliance could bring about early improvement of MPD syndrome. It is suggested that the thickness of the palatal plate was an important factor in obtaining the clinical effect.

Adult↗

Argyrophilic nucleolar organizer regions (AgNORs) in mucosal epithelium under experimental denture bases in rats.

The purpose of this study was to evaluate changes in the argyrophilic nucleolar organizer region (AgNOR) counts in mucosal epithelium induced by continuous or intermittent compressive pressure exerted through experimental denture bases and to examine the relationships between the AgNOR count, histopathological changes and the intensity of the pressure under denture bases. Continuous or intermittent compressive pressure exerted through the denture bases was applied to the hard palate of the molar region in rats. A morphometric analysis of AgNORs was performed in denture-supporting tissue 3 days and 1, 2, 4, 8, 12 and 20 weeks after the denture insertion. From the results of this study, it was found that non-pressure contact of the denture bases with palatal tissues did not change the AgNOR count. The AgNOR count was decreased by continuous or intermittent compressive pressure, and then recovered to almost the same level as with the non-pressure contact at 20 weeks following a decrease of the pressure. The AgNOR counts in the epithelium under the denture bases were revealed to be related to the histopathological changes in the denture-supporting tissues and the intensity of the pressure under the denture bases.

Acrylic Resins↗

Effect of eccentric clenching on mandibular deviation in the vicinity of mandibular rest position.

Although the mechanical compression of the temporomandibular joint (TMJ), which could be caused by bruxism, would probably result in a slight change of the occlusal relationship, the effect of clenching in the eccentric mandibular position on the occlusal contact has not yet been clarified. This study aimed to investigate the effect of eccentric clenching on bilateral condylar position and thus to estimate any change of occlusal contact. Before and after voluntary clenching, with one third of the maximal voluntary clenching force, for 3 min at the canine edge-to-edge position, vertical deviation of the bilateral condyles was measured at the 1 mm open mandibular position. This was regulated by the three-dimensional position of the anterior reference point which stands for the incisor point. The mean vertical displacement of the highly deviated side of the condyle was 141+/-55 microm, and the calculated mean displacement of the mandibular first molar region of the highly deviated side was 65+/-27 microm. From the results of this study, it was revealed that the eccentric clenching gave rise to three-dimensional deviation of the mandible even when the mandible was in the vicinity of the rest position.

Adult↗

Comparative study of the temporomandibular joint space in maximum intercuspation and canine edge-to-edge positions in deep bite and non-deep bite subjects.

In order to study the relationship between morphological properties of the TMJ and the mathematically predicted force distribution in the TMJ, the geometric distribution of the joint space on top of the condylar surfaces was evaluated. Seven deep bite subjects and seven non-deep bite subjects were used, and the joint space in the maximum intercuspation and canine edge-to-edge positions was analysed in each group. Standardized images of the TMJ were taken with computed tomography (CT) using a mandible positioner. The comparative ratio of joint space (CRJS) between the maximum intercuspation and the canine edge-to-edge positions was calculated and summarized on the map of the mean morphological outline of the condyle. On the balancing-side condyle, the CRJS of small value was distributed mainly on the anterior edge of the condyle in the non-deep bite group, whereas, in the deep bite group, it was distributed on the centre of the condyle. On the working-side condyle, the small CRJS was distributed around the lateral pole of the condyle in the non-deep bite group, whereas, in the deep bite group, it was found around the posterior part of the condyle. The distribution pattern of CRJS on the upper surface of the condyle in the non-deep bite group was consistent with the results of previous studies on mathematical simulation of TMJ loading. From the results of this study, it was suggested that the distribution of mechanical loading on the TMJ in the eccentric mandibular position would be highly affected by the comparative ratio of joint space. As the comparative ratio of joint space would be highly affected by the condylar position, the analysis of the morphology of the TMJ in relation to mechanical joint loading, in a future investigation, should be carried out on specific mandibular positions in relation to the function of the TMJ to be studied.

Adult↗

Vibrating-traction method for mechanical joint distraction.

Mechanical static traction has been adopted as one of the treatment procedures for joint diseases and fractures. The effect of mechanical vibration on the mechanical traction of the temporomandibular joint was studied in six human subjects. A mechanical traction force of 2000 gf was applied as a dynamic traction force with mechanical vibration or as a static traction force. The dynamic traction force with vibration was applied for 5 min to the right temporomandibular joint using a vibrating-traction apparatus which generated mechanical vibrations of 1000, 3000 or 4000 Hz. Application of a static traction force for 5 min was used as a control condition. Vertical condylar displacement was mathematically evaluated from the deviation of the mandible using Eddy current displacement sensors which were attached to the maxillary dental arch. Among the three vibration frequencies, 3000 Hz resulted in the maximum vertical condylar displacement for all six subjects, showing the mean condylar displacement of 668+/-242 microm. In contrast, vibrations of 1000 and 4000 Hz showed a smaller traction effect. Application of the static traction force for 5 min resulted in a mean vertical condylar displacement of 5.7+/-4.9 microm, showing almost no traction effect to the joint. From the results of this study, it was revealed that vibrating traction could distract a joint more effectively than could static traction and that the traction force necessary for effective vibrating traction was less than that for static traction.

Adult↗

New telescopic crown design for removable partial dentures.

STATEMENT OF PROBLEM: Special technical skills and experiences are required to fabricate a telescopic crown to provide adequate retention with precise frictional retention ("conus friction force") between coping and telescope. It is also difficult to control clinically alterations of retentive forces after prolonged usage. PURPOSE: This study examined an innovative telescopic crown system for removable partial dentures that can be fabricated without special technical skill or experience and readily adjusted retentive forces. The retention of telescopic crowns was investigated after repeated insertion/separation tests. MATERIAL AND METHODS: Ten telescopic crowns were constructed to evaluate retentive forces. Each telescopic crown was adjusted to provide a retentive force of approximately 9.8 N. Each telescopic crown was then subjected to 10,000 insertion/separation cycles, and retentive force of each telescopic crown was recorded initially and after every 1,000 cycles. The retentive force of each telescopic crown was re-adjusted after these measurements to provide a retentive force of approximately 9.8 N. The retentive force was recorded a second time after each 1,000 insertion/separation cycles up to 10,000 cycles. RESULTS: Retention of the telescopic crowns gradually diminished, depending on the number of insertion/separation cycles. The mean retentive force after 10,000 insertion/separation cycles was over 2 N. All 10 telescopic crowns were re-adjusted to exert a retentive force of 9.8 N after the initial 10,000 cycles, and the retentive force also diminished on the second 10,000 cycles. CONCLUSIONS: Reduction of retention was dependent on insertion/separation cycles. This new telescopic crown with reduced retention could be easily readjusted. Readjusted retentive forces were at least equivalent to the initial retention.

Analysis of Variance↗

In situ microsampling technique for identification of elements of a restoration with exposed metal to identify potential allergens.

STATEMENT OF PROBLEM: For clinical investigations of allergic reactions to dental materials, it is necessary to know the type of metal used in restorations in the mouth of the patient. However, an intraoral method of sampling the dental alloy without removing the metal restoration has not yet been established. PURPOSE: This study attempted to establish a clinically serviceable method for microsampling dental alloy. MATERIAL AND METHODS: A piece of silicone sampling tube is held on the surface of the metal restoration. This surface was ground with a carbide bur through the sampling tube, and the ground metal particles were then recovered from the inner surface of the tube. The recovered sample was subjected to energy-dispersive x-ray microanalysis. The percentage recovery of ground alloy by this microsampling method, which was the ratio of the recovered weight of metal to the total weight of the metal ground, was evaluated using 3 mm diameter x 1 mm thick disk-shaped specimens of Ag-Au-Pd and Ni-Cr alloys. RESULTS: Elemental analysis of the retrieved alloys identified the component elements in the alloy compositions. The percentage recovery by this microsampling method was 75.0% for Ag-Au-Pd alloy and 69.9% for Ni-Cr alloy, respectively. CONCLUSIONS: The microsampling method demonstrated a relatively high percentage recovery of the ground alloy particles. This microsampling method would be of great benefit clinically to patients who have allergic reactions to dental materials.

Allergens↗

The effect of diabetes mellitus on histopathological changes in the denture-supporting tissues under continuous mechanical pressure in rat.

The histopathological changes in denture-supporting tissues of streptozotocin-induced diabetes mellitus rat were studied in relation to continuous mechanical pressure exerted through an experimental denture base. The experimental dentures were designed to load continuous mechanical pressures (3.4, 1.5 or 0.5 kPa) to the hard palate of the molar region of a rat. From the results of this study, the following conclusions were drawn: the streptozotocin-induced diabetic condition (1) tended to prolong the appearance period of a shortened epithelial ridge, and weakened the phenomenon, (2) reduced the appearance period and severity of the compression of epithelium, (3) delayed the time of manifestation of the proliferative change in the recovery process of the shortened epithelial ridge, and weakened the phenomenon, (4) prolonged the appearance period of the compressed lamina propria mucosae, and enhanced the phenomenon, (5) reduced the number of osteoclasts, (6) lowered the threshold for induction of the osteoclastic bone resorption to between 1.5 and 0.5 kPa, (7) inhibited the appearance of osteoblast which follows the disappearance of osteoclasts, (8) did not induce any inflammatory change, and (9) tended to enhance the longitudinal change of the continuous mechanical pressure. The histopathological changes in the denture-supporting tissues of the streptozotocin-induced diabetes mellitus rat related highly to the longitudinal change of the continuous mechanical pressure exerted through the denture base. From the results of this study, it was suggested that the streptozotocin-induced diabetic condition lowers the tolerance of the denture-supporting tissues to continuous mechanical pressure.

Animals↗