Frequency of subacute resumption of isthmus conduction after ablation of atrial flutter.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to S Mittal.
Explore the source record for details and available documents.
Nonlinear-dynamical control techniques, also known as chaos control, have been used with great success to control a wide range of physical systems. Such techniques have been used to control the behavior of in vitro excitable biological tissue, suggesting their potential for clinical utility. However, the feasibility of using such techniques to control physiological processes has not been demonstrated in humans. Here we show that nonlinear-dynamical control can modulate human cardiac electrophysiological dynamics by rapidly stabilizing an unstable target rhythm. Specifically, in 52/54 control attempts in five patients, we successfully terminated pacing-induced period-2 atrioventricular-nodal conduction alternans by stabilizing the underlying unstable steady-state conduction. This proof-of-concept demonstration shows that nonlinear-dynamical control techniques are clinically feasible and provides a foundation for developing such techniques for more complex forms of clinical arrhythmia.
BACKGROUND AND HYPOTHESIS: There is no method available to predict the relative antianginal efficacy of beta blockers and calcium-channel antagonists. The present study was undertaken to assess the role of silent ischemic interval (SII) on exercise treadmill test (ETT) as a predictor of response to therapy with metoprolol and diltiazem in patients with stable angina. METHODS: Thirty-four patients with stable angina were divided into two groups depending upon the presence or absence of an SII gap of at least 1 min between onset of ST depression and appearance of angina on ETT. Metoprolol (50-100 mg twice daily) and diltiazem (60-120 mg three times daily) were randomly assigned for 6 weeks to patients in each group, and then patients were crossed over for further 6 weeks after a washout period of 2 weeks. Antianginal efficacy was assessed by clinical and exercise parameters. RESULTS: In patients with SII, the clinical responder rate was better with metoprolol than with diltiazem (90 vs. 60%, respectively), and on ETT, metoprolol produced significant improvement in the total exercise time (p< 0.01), time to 1 mm ST depression (p <0.01), time to angina (p <0.01), and a significant decrease in peak rate-pressure product (p<0.001), whereas diltiazem had no significant effect on exercise parameters. However, in patients without SII, metoprolol and diltiazem had a similar clinical responder rate (57%), and both produced a significant increase in total exercise time (p < 0.01), time to 1 mm ST depression (p < 0.01), and time to angina (p < 0.01). In addition, metoprolol had a significant effect on peak rate-pressure product (p < 0.001). CONCLUSION: Silent ischemic interval on ETT can be a predictor of response to antianginal therapy in stable angina, as patients with SII respond better to metoprolol and those without SII respond equally to both metoprolol and diltiazem.
In an audit to evaluate fetal gastrointestinal (GIT) malformations, case sheets of all mothers who gave birth to newborns with GIT malformations were analysed regarding the maternal history, prenatal ultrasound and the postnatal structural malformations and perinatal management. In 1999, eleven babies were born with gastrointestinal malformations, one was a still birth. Nine had associated malformations of other systems, two had trisomy 21. Eight babies were operated in the immediate newborn period, 5 survived. Ultrasound was not very accurate in the diagnosis of GIT anomaly in this series. In view of associated chromosomal and structural anomaly a fetal ECHO and genetic amniocentesis is warranted. Most of these babies require immediate surgery after birth, so they need to be delivered in a centre which is equipped with good neonatal and pediatric surgery care.
OBJECTIVES: This study was designed to determine the incidence and prognostic significance of inducible ventricular fibrillation (VF) in patients with coronary artery disease (CAD) and unexplained syncope. BACKGROUND: Current American College of Cardiology/American Heart Association practice guidelines recommend implantation of internal cardioverter-defibrillators (ICDs) in patients with unexplained syncope in whom either ventricular tachycardia (VT) or VF is inducible during electrophysiologic (EP) testing. Although the prognostic significance of inducible monomorphic VT is known, the significance of inducible VF remains undefined. METHODS: We evaluated 118 consecutive patients with CAD and unexplained syncope who underwent EP testing. Sustained monomorphic VT was inducible in 53 (45%) patients; in 20 (17%) patients, VF was the only inducible arrhythmia; and no sustained ventricular arrhythmia was inducible in the remaining 45 (38%) patients. The latter two groups of 65 (55%) patients make up the study population. RESULTS: There were 16 deaths among the study population during a follow-up period of 25.3 +/- 19.6 months. The overall one- and two-year survival in these patients was 89% and 81%, respectively. No significant difference in survival was observed between patients with and without inducible VF (80% power to detect a fourfold survival difference). CONCLUSIONS: In 17% of patients with CAD and unexplained syncope, VF is the only inducible ventricular arrhythmia. Within the limits of this pilot study, long-term follow-up of patients with and without inducible VF demonstrates no difference in survival between the two groups. Therefore, the practice of ICD implantation in patients with CAD, unexplained syncope and inducible VF, especially with triple ventricular extrastimuli, may merit reconsideration.
BACKGROUND: Although tilt testing has emerged as the test of choice for assessing patients with suspected neurally mediated syncope, the optimum duration of tilt testing is poorly defined. This in part relates to the absence of a gold standard to assess test performance. OBJECTIVE: Our purpose was to formally estimate the effects of varying duration of drug-free tilt testing on test performance in diagnosing neurally mediated syncope. DESIGN: If a test's specificity is known, then in the absence of a gold standard an imputed (estimated) sensitivity may be calculated on the basis of the observed diagnostic yield in a given population as a function of assumed population prevalence. We determined the relationship of specificity to drug-free tilt test duration by use of data from 11 previous studies reporting the results of drug-free tilt testing in a total of 435 control subjects (60 to 80 degrees of tilt, footboard support, 15- to 60-minute duration). Data (weighted for study size) were fit to an exponential function relating specificity to tilt duration. Test yield was evaluated as a function of tilt duration in 213 consecutive patients referred to our laboratory for the evaluation of suspected neurally mediated syncope who underwent passive tilt testing for up to 30 to 60 minutes. RESULTS: The estimated specificity of tilt testing was 94% at 30 minutes, 92% at 40 minutes, and 88% after 60 minutes of passive tilt. The cumulative yield of tilt testing was only 17% at 30 minutes, 22% at 40 minutes, and 28% after 60 minutes. On the basis of an estimated population prevalence of 25% to 50% in this referral population, imputed sensitivity is 27% to 48% at 30 minutes, 36% to 64% at 40 minutes, and 43% to 74% after 60 minutes of passive tilt. The overall diagnostic accuracy was not strongly influenced by tilt duration beyond 30 minutes and ranged from 60% to 84%. CONCLUSIONS: Passive tilt testing (ie, tilt testing without pharmacologic provocation) for durations of up to 60 minutes has limited sensitivity for diagnosing neurally mediated syncope. For populations with a pretest likelihood of 25% to 50%, test results are inaccurate in one to two fifths of patients.
In vitro experiments have shown that the complexity of atrioventricular nodal (AVN) conduction dynamics increases with heart rate. Although complex AVN dynamics (e.g., alternans) have been observed clinically, human AVN dynamics during rapid pacing have not been systematically investigated. We studied such dynamics during ventricular-triggered atrial pacing in 37 patients with normal AVN function (18 patients with dual AVN pathway physiology and 19 patients without). Alternans, which always resulted from single pathway conduction, occurred in 18 patients. In 16 patients (3 of whom also had alternans), quasisinusoidal AVN conduction oscillations occurred (mean frequency 0.02 Hz); such oscillations have not been previously reported. There were no significant differences in the dynamics for patients with or without dual AVN pathways. To illuminate the governing dynamic mechanism, a second atrial pacing trial was performed on 12 patients after autonomic blockade. Blockade facilitated alternans but inhibited oscillations. This study suggests that rapid AVN excitation in vivo can lead to autonomically mediated AVN conduction oscillations or single pathway alternans that are a function of inherent nonlinear dynamic AVN tissue properties.
BACKGROUND: CVT-510, N-(3(R)-tetrahydrofuranyl)-6-aminopurine riboside, is a selective A(1)-adenosine receptor agonist with potential potent antiarrhythmic effects in tachycardias involving the atrioventricular (AV) node. This study, the first in humans, was designed to determine the effects of CVT-510 on AV nodal conduction and hemodynamics. METHODS AND RESULTS: Patients in sinus rhythm with normal AV nodal function at electrophysiologic study (n = 32) received a single intravenous bolus of CVT-510. AH and HV intervals were measured during sinus rhythm and during atrial pacing at 1, 5, 10, 15, 20, 30, 45, and 60 minutes after the bolus. Increasing doses of CVT-510 (0.3 to 10 microg/kg) caused a dose-dependent increase in the AH interval. At 1 minute, a dose of 10 microg/kg increased the AH interval during sinus rhythm from 93 +/- 23 msec to 114 +/- 37 msec, p = 0.01 and from 114 +/- 31 msec to 146 +/- 44 msec during atrial pacing at 600 msec, p = 0.003). The AH interval returned to baseline by 20 minutes. CVT-510 at doses of 0.3 to 10 microg/kg had no effect on sinus rate, HV interval, or systemic blood pressure, and was not associated with serious adverse effects. At doses of 15 and 30 microg/kg, CVT-510 produced transient second/third degree AV heart block in all four patients treated. One of these patients also had a prolonged sedative effect that was reversed with aminophylline. CONCLUSIONS: CVT-510 promptly prolongs AV nodal conduction and does not affect sinus rate or blood pressure. Selective stimulation of the A(1)-adenosine receptor by CVT-510 may be useful for immediate control of heart rate in atrial fibrillation/flutter and to convert paroxysmal supraventricular tachycardia to sinus rhythm, while avoiding vasodilatation mediated by the A(2)-adenosine receptor, as well as the vasodepressor and negative inotropic effects associated with beta-adrenergic receptor blockade and/or calcium channel blockers.
Residual seizures after functional hemispherectomy occur in approximately 20% of patients with catastrophic epilepsy. These episodes are traditionally attributed to incomplete disconnection, persistent epileptogenic activity in the ipsilateral insular cortex, or bilateral independent epileptogenic activity. The authors report on the case of an 8-year-old boy with an intractable seizure disorder who had classic frontal adversive seizures related to extensive unilateral left hemispheric cortical dysplasia. The initial intervention consisted of extensive removal of the epileptic frontal and precentral dysplastic tissue and multiple subpial transections of the dysplastic motor strip, guided by intraoperative electrocorticography, Subsequently, functional hemispherectomy including insular cortex resection was performed for persistent attacks. After a seizure-free period of 6 months, a new pattern ensued, consisting of an aura of fear, dystonic posturing of the right arm, and unusual postictal hyperphagia coupled with an interictal diencephalic-like syndrome. Electroencephalography and ictal/interictal single-photon emission computerized tomography were used to localize the residual epileptic discharges to deep ipsilateral structures. Results of magnetic resonance imaging indicated a complete disconnection except for a strip of residual frontobasal tissue. Therefore, a volumetric resection of the epileptogenic frontal basal tissue up to the anterior commissure was completed. The child has remained free of seizures during 21 months of follow-up review. Standard hemispherectomy methods provide extensive disconnection, despite the presence of residual frontal basal cortex. However, rarely, and especially if it is dysplastic, this tissue can represent a focus for refractory seizures. This is an important consideration in determining the source of ongoing seizures posthemispherectomy in patients with extensive cortical dysplasia. It remains important to assess them fully before considering their disease refractory to surgical treatment.
OBJECT: Selective posterior rhizotomy is a well-established treatment for spasticity associated with cerebral palsy. At most medical centers, responses of dorsal rootlets to electrical stimulation are used to determine ablation sites; however, there has been some controversy regarding the reliability of intraoperative stimulation. The authors analyzed data obtained from the McGill Rhizotomy Database to determine whether motor responses to dorsal root stimulation were reproducible. METHODS: A series of 77 patients underwent selective dorsal rhizotomy at a single medical center. The dorsal roots from L-2 to S-2 were stimulated to determine the threshold amplitude. The roots were then stimulated at 2 to 4 times the highest threshold with a 1-second 50-Hz train. A second stimulation run of the entire dorsal root was performed before it was divided into rootlets. Rootlets were individually stimulated and sectioned according to the extent of abnormal electrophysiological propagation. Motor responses were recorded by electromyography and were also assessed by a physiotherapist, and grades of 0 to 4+ were assigned. The difference in grades between the first and second stimulation trains was determined for 752 roots. Statistical analysis demonstrated a clear consistency in motor responses between the two stimulation runs, both in the electromyographic readings and the physiotherapist's assessment. More than 93% of dorsal roots had either no change or a difference of only one grade between the two trials. Furthermore, the vast majority of dorsal roots assigned a grade of 4+ at the first trial maintained the same maximally abnormal electrophysiological response during the second stimulation run. CONCLUSIONS: This study indicates that currently used techniques are reproducible and reliable for selection of abnormal rootlets. Intraoperative electrophysiological stimulation can be valuable in achieving a balance between elimination of spasticity and preservation of underlying strength.
Discrete subvalvular aortic stenosis is a relatively rare condition in adults. It is often diagnosed during first decade of life especially in association with other congenital malformations. Isolated form of discrete subvalvular aortic stenosis may however silently progress from innocent murmurs of childhood and adolescence to symptomatic left ventricular outflow tract obstruction in adults. Certain overt and subtle morphological abnormalities may underlie the initial expression as well as high recurrence rates after surgical resection of sub aortic membrane. Though surgical resection is the only treatment available, debate on the surgical technique and appropriate timing of surgery continues. Close followup with serial echocardiographic examinations in patients detected to have functional murmurs during childhood may be helpful in early detection of subvalvular aortic stertosis.
Patterns of permanent tooth emergence in Gujjars were studied in a cross-sectional sample of 483 children ranging in age from 6 to 13 years. Females were markedly advanced in permanent tooth emergence times over males, but no such sex differences were observed in sequence of emergence. Differences between median emergence times of right and left side antimers were significant for only 4 of 28 instances (14.29%), namely central incisors, mandibular first molars in males and lateral maxillary incisors in females. In general mandibular teeth except premolars tended to emerge earlier than their maxillary counterparts. The quiescent period between first and second tooth emergence stages was longer in males than in females. Mandibular depth and morphological facial length were very significantly correlated (p < 0.01) with the number of permanent teeth present in the oral cavity.
BACKGROUND: Clinical studies have shown that biphasic shocks are more effective than monophasic shocks for ventricular defibrillation. The purpose of this study was to compare the efficacy of a rectilinear biphasic waveform with a standard damped sine wave monophasic waveform for the transthoracic cardioversion of atrial fibrillation. METHODS AND RESULTS: In this prospective, randomized, multicenter trial, patients undergoing transthoracic cardioversion of atrial fibrillation were randomized to receive either damped sine wave monophasic or rectilinear biphasic shocks. Patients randomized to the monophasic protocol (n=77) received sequential shocks of 100, 200, 300, and 360 J. Patients randomized to the biphasic protocol (n=88) received sequential shocks of 70, 120, 150, and 170 J. First-shock efficacy with the 70-J biphasic waveform (60 of 88 patients, 68%) was significantly greater than that with the 100-J monophasic waveform (16 of 77 patients, 21%, P<0.0001), and it was achieved with 50% less delivered current (11+/-1 versus 22+/-4 A, P<0.0001). Similarly, the cumulative efficacy with the biphasic waveform (83 of 88 patients, 94%) was significantly greater than that with the monophasic waveform (61 of 77 patients, 79%; P=0.005). The following 3 variables were independently associated with successful cardioversion: use of a biphasic waveform (relative risk, 4.2; 95% confidence intervals, 1.3 to 13.9; P=0.02), transthoracic impedance (relative risk, 0.64 per 10-Omega increase in impedance; 95% confidence intervals, 0.46 to 0.90; P=0.005), and duration of atrial fibrillation (relative risk, 0.97 per 30 days of atrial fibrillation; 95% confidence intervals, 0.96 to 0.99; P=0.02). CONCLUSIONS: For transthoracic cardioversion of atrial fibrillation, rectilinear biphasic shocks have greater efficacy (and require less energy) than damped sine wave monophasic shocks.
Idiopathic ventricular tachycardia (VT) is characterized by two predominant forms. The most common form originates from the right ventricular outflow tract and presents as repetitive monomorphic VT or exercise-induced VT. The tachycardia is adenosine sensitive and is thought to be because of cAMP-mediated triggered activity. The other major form of idiopathic VT is owing to verapamil-sensitive intrafascicular re-entrant tachycardia, which most often originates in the region of the left posterior fascicle. Both forms of idiopathic VT can be readily treated with radiofrequency catheter ablation.
The analysis used yohimbine HCl solution prepared from commercially available yohimbine HCl powder. Stability-indicating high-performance liquid chromatographic (HPLC) assay procedures were established and utilized to analyze the concentration of the drug. The method proved to be a simple model since it does not contain a buffer system. The mobile phase used, a methanol:water 70:30 ratio, was similar to that suggested by the manufacturer for the storage of the column. Therefore, the solvent system saves analytical processing time since it does not require a change in the mobile phase before and after the analysis. The analytical method has been shown to be stability indicating. The assay method showed a retention time for yohimbine of 4.2 min; for caffeine, the internal standard, it was 2.3 min. The standard deviation and the coefficient of variation were under acceptable limits of 2% and were specifically 1.51% and 1.35% for within-day and between-day samples, respectively. The results showed that the degradation products obtained from stressing yohimbine HCl by heat and extremes in pH did not interfere with the yohimbine HCl peak, although the internal standard, caffeine, did show some interference due to having a retention time similar to the degradation products.
We report two cases of unicornuate uterus with functioning rudimentary horn to highlight that Mullerian duct anomalies should be considered in the differential diagnosis of severe dysmenorrhoea even in normally menstruating girls.
Explore the source record for details and available documents.