Publications and source records attributed to S Moehrs.

2 recordsLinked to original sources

Fast 3D-EM reconstruction using Planograms for stationary planar positron emission mammography camera.

At the University of Pisa we are building a PEM prototype, the YAP-PEM camera, consisting of two opposite 6 x 6 x 3 cm3 detector heads of 30 x 30 YAP:Ce finger crystals, 2 x 2 x 30 mm3 each. The camera will be equipped with breast compressors. The acquisition will be stationary. Compared with a whole body PET scanner, a planar Positron Emission Mammography (PEM) camera allows a better, easier and more flexible positioning around the breast in the vicinity of the tumor: this increases the sensitivity and solid angle coverage, and reduces cost. To avoid software rejection of data during the reconstruction, resulting in a reduced sensitivity, we adopted a 3D-EM reconstruction which uses all of the collected Lines Of Response (LORs). This skips the PSF distortion given by data rebinning procedures and/or Fourier methods. The traditional 3D-EM reconstruction requires several times the computation of the LOR-voxel correlation matrix, or probability matrix {p(ij)}; therefore is highly time-consuming. We use the sparse and symmetry properties of the matrix {p(ij)} to perform fast 3D-EM reconstruction. Geometrically, a 3D grid of cubic voxels (FOV) is crossed by several divergent 3D line sets (LORs). The symmetries occur when tracing different LORs produces the same p(ij) value. Parallel LORs of different sets cross the FOV in the same way, and the repetition of p(ij) values depends on the ratio between the tube and voxel sizes. By optimizing this ratio, the occurrence of symmetries is increased. We identify a nucleus of symmetry of LORs: for each set of symmetrical LORs we choose just one LOR to be put in the nucleus, while the others lie outside. All of the possible p(ij) values are obtainable by tracking only the LORs of this nucleus. The coordinates of the voxels of all of the other LORs are given by means of simple translation rules. Before making the reconstruction, we trace the LORs of the nucleus to find the intersecting voxels, whose p(ij) values are computed and stored with their voxel coordinates on a hard disk. Only the non-zero p(ij) are considered and their computation is performed just once. During the reconstruction, the stored values are loaded and are available in the random access memory for all of the operations of normalization, backprojection and projection: these are now performed rapidly, because the application of the translation rules is much faster than the probability computations. We tested the algorithm on Monte Carlo data fully simulating the typical YAP-PEM clinical condition. The adopted algorithm gives an excellent positioning capability for hot spots in the camera FOV. To use all of the possible skew LORs in the FOV avoids the software rejection of collected data. Reconstructed images indicate that a 5mm diameter tumor of 37 kBq/cm3, in an active breast with a 10:1 Tissue to Background ratio (T/B), with a 10 min acquisition, for a head distance of 5 cm, can be detected by the YAP-PEM with a SNR of 8.7+/-1.0. The obtained SNR values depend linearly on the tumor volume. The algorithm allows one to discriminate between two hot sources of 5.0 mm diameter if they do not lie on the same axis. The YAP-PEM is now in the assembly stage.

Algorithms↗

Internet patient records: new techniques.

BACKGROUND: The ease by which the Internet is able to distribute information to geographically-distant users on a wide variety of computers makes it an obvious candidate for a technological solution for electronic patient record systems. Indeed, second-generation Internet technologies such as the ones described in this article--XML (eXtensible Markup Language), XSL (eXtensible Style Language), DOM (Document Object Model), CSS (Cascading Style Sheet), JavaScript, and JavaBeans--may significantly reduce the complexity of the development of distributed healthcare systems. OBJECTIVE: The demonstration of an experimental Electronic Patient Record (EPR) system built from those technologies that can support viewing of medical imaging exams and graphically-rich clinical reporting tools, while conforming to the newly emerging XML standard for digital documents. In particular, we aim to promote rapid prototyping of new reports by clinical specialists. METHODS: We have built a prototype EPR client, InfoDOM, that runs in both the popular web browsers. In this second version it receives each EPR as an XML record served via the secure SSL (Secure Socket Layer) protocol. JavaBean software components manipulate the XML to store it and then to transform it into a variety of useful clinical views. First a web page summary for the patient is produced. From that web page other JavaBeans can be launched. In particular, we have developed a medical imaging exam Viewer and a clinical Reporter bean parameterized appropriately for the particular patient and exam in question. Both present particular views of the XML data. The Viewer reads image sequences from a patient-specified network URL on a PACS (Picture Archiving and Communications System) server and presents them in a user-controllable animated sequence, while the Reporter provides a configurable anatomical map of the site of the pathology, from which individual "reportlets" can be launched. The specification of these reportlets is achieved using standard HTML forms and thus may conceivably be authored by clinical specialists. A generic JavaScript library has been written that allows the seamless incorporation of such contributions into the InfoDOM client. In conjunction with another JavaBean, that library renders graphically-enhanced reporting tools that read and write content to and from the XML data-structure, ready for resubmission to the EPR server. RESULTS: We demonstrate the InfoDOM experimental EPR system that is currently being adapted for test-bed use in three hospitals in Cagliari, Italy. For this we are working with specialists in neurology, radiology, and epilepsy. CONCLUSIONS: Early indications are that the rapid prototyping of reports afforded by our EPR system can assist communication between clinical specialists and our system developers. We are now experimenting with new technologies that may provide services to the kind of XML EPR client described here.

Internet↗