PubMed Health⌕ Search

Biomedical subjects

S N Amin

Publications and source records attributed to S N Amin.

15 recordsLinked to original sources

V-Y advancement flap for treatment of fistula-in-ano.

PURPOSE: The management of high fistula-in-ano presents a difficult surgical challenge. Laying open of high transsphincteric, intersphincteric, and suprasphincteric fistulas is associated with incontinence. Mucosal advancement flap can be technically difficult and is associated with ectropion and incontinence. We report a new technique for the treatment of fistulas, which may eliminate these problems. PATIENTS AND METHODS: Between 1997 and 2002, 18 patients (13 males), median age 46 (range, 25-64) years with high fistula-in-ano were treated. There were ten transsphincteric, four intersphincteric, and four suprasphincteric fistulas. In all patients, perianal sepsis was allowed to resolve completely with a drainage seton before definitive surgery. The surgical technique used involved core fistulectomy, curettage of any cavity, closure of the defect in the internal anal sphincter, and a V-Y advancement buttock flap to cover the internal opening, leaving the site of the external opening for drainage while preserving both internal and external sphincters. Outcome was assessed in terms of healing and continence. RESULTS: Most patients were discharged from the hospital within 48 hours. Median follow-up was 19 (range, 3-60) months. There were three patients who failed to heal. Of these, two underwent repeat surgery and healed. Two further patients had recurrent fistulas, both of whom continued with conservative treatment. Overall, 15 of 18 (83 percent) patients experienced healing of their fistula. Continence was preserved in all patients. CONCLUSION: This procedure is easy to perform, healing is rapid, and it appears to be effective in curing fistula-in-ano while preserving both external and internal anal sphincters.

Adult↗

Nanofiltration of single plasma donations: feasibility study.

BACKGROUND AND OBJECTIVES: Major technical developments have been made in recent years to improve the quality and safety of human plasma for transfusion and fractionation. The present study was performed to assess, for the first time, the feasibility of applying a nanofiltration process, using 75-nm and 35-nm mean pore size membranes (Planova) 75N and Planova 35N), to human plasma. MATERIALS AND METHODS: Ten apheresis plasma units were obtained from 10 plasma donors. Within 4 h of collection, plasma was subjected to leucoreduction and filtration (using 75-nm and 35-nm mean pore size membranes) at 35 degrees C, at less than 1 bar pressure. Aliquots of plasma were taken at all steps of the filtration procedure and numerous plasma quality parameters were measured. In addition, six hepatitis C virus (HCV)-positive plasma donations were experimentally subjected to the same filtration sequence and subsequently assessed by RNA polymerase chain reaction (PCR) and branched-chain DNA-quantification assays. RESULTS: Leucoreduced plasma can be reproducibly nanofiltered onto a sequence of 75-nm and 35-nm membranes, at a flow rate of 450 ml/h and a temperature of 35 +/- 0.5 degrees C. Some protein dilution, or loss, was found during filtration, but the plasma filtered through membranes with a mean pore size of 75 nm and 35 nm met in vitro specifications for use in transfusion or fractionation. There were no signs of activation of the coagulation system. HCV-positive plasma donations became negative, as judged by PCR and branched-chain DNA assay results, after filtration through the 35-nm membrane. CONCLUSIONS: It is possible to apply a 75 + 35-nm filtration process to leucoreduced human plasma. This technology may have important future benefits in improving the quality and safety of plasma, by removing blood cell debris and infectious agents.

Blood Donors↗

[Further experiences with transplantation of the head of the fibula].

We are presenting our experience with vascularized epiphyseal transplantation of the upper end of the fibula, based distally on the anterior tibial artery in two patients, one suffering from septic epiphysitis of the hip with complete loss of the head and neck of the femur, the other suffering from radial club hand following septic loss of the radius, excluding its proximal and distal articular segments. In the first patient, the fibular epiphysis bridged the bone defect and provided growth at the neck of the femur. This restored hip stability, reduced limb-length discrepancy, initiated some degree of acetabular development, and maintained a functional range of hip motion. In the second patient, transplantation of the upper end of the fibula was used to bridge a gap resulting from complete resorption of the right radius and provide for growth of the radius. At follow-up, complete union of the graft was noted. The club-hand appearance improved markedly. Pronation and supination were regained. However, donor-site morbidity was a problem. It included sloughing of part of the peroneal muscles and the skin edge of the incision. This was due to loss of the anterior tibial artery as well as injury to the peroneal vessel collaterals supplying the skin and peroneal muscles. The latter occurred due to opening of the posterior compartment of the leg in an attempt to locate the anterior tibial artery at its origin from the popliteal artery. It is therefore concluded, that transplantation of the upper end of the fibula is a valuable reconstructive alternative for septic epiphysitis with complete loss of the head and neck of the femur as well as for septic loss of the radius. However, whenever an extended part of the upper end of the fibula needs being harvested, this should be performed through an anterior approach, in order to avoid sloughing of the skin and muscles of the anterior and lateral compartments of the leg.

Arthritis, Infectious↗

Lateral repair of parastomal hernia.

INTRODUCTION: Parastomal hernia is a common complication of stoma construction. Although the majority of patients are asymptomatic, about 10% require surgical correction. AIMS: We describe a new surgical approach for the repair of parastomal hernias, which avoids both the need for laparotomy and stoma mobilization. PATIENTS AND METHODS: Nine patients (4 female) with parastomal hernia underwent surgical repair. Median age was 55 years (range 38-73 years). There were 8 para-ileostomy herniae and one paracolostomy hernia. A lateral incision was made approximately 10 cm from the stoma, and carried down to the rectus sheath. The dissection was carried medially towards the stoma, and around the defect in the abdominal musculature. The hernia sac was excised when possible and the fascial defect closed with non-absorbable, monofilament suture. A polyprolene mesh was placed round the stoma by making a slit in the mesh. The skin was closed with subcuticular monofilament absorbable suture. RESULTS: All patients returned to normal diet on the first postoperative day, and were discharged from hospital within 72 h. There were no wound infections, and no recurrences after a median follow up of 6 months (range 3-12 months). DISCUSSION: The technique we describe is simple and avoids the need of laparotomy. The mucocutaneous junction of the stoma is not disturbed, reducing the risk of contamination of the mesh, stenosis or retraction of the stoma. Grooving of the stoma and difficulty in fitting appliances is avoided because the wound is not placed near the mucocutaneous junction. This approach may be superior to other mesh repairs for parastomal hernia.

Adult↗

Defunctioning loop ileostomy and stapled side-to-side closure has low morbidity.

INTRODUCTION: Low pelvic anastomoses are associated with a high leak rate. Therefore, defunctioning loop ileostomies are being increasingly fashioned to protect against the consequences of a leak. However, the reported complication rates of such stoma creation and closure is between 5.7-69%. AIMS: To determine the outcome associated with construction and side-to-side closure of loop ileostomies in one specialist unit. PATIENTS AND METHODS: Data were obtained from a computer audit and case note analysis. RESULTS: Between 1994 and 1998, 71 patients (41 M, 30 F) with a median age of 51 years (range 19-88 years) had a loop ileostomy constructed for: (i) 26 ileoanal pouches; (ii) 36 left colonic and rectal resections; and (iii) 9 for other reasons. Side-to-side stoma closure was achieved using a GIA linear stapler through a parastomal incision. The median hospital stay following stoma creation was 12 days (range 7-63 days) and stoma closure was 7 days (range 6-16 days). The median time to closure was 140 days (range 10-790 days). There were no ileostomy-related deaths. There were 10 (13.8%) ileostomy-related complications, 4 following creation and 6 following closure. CONCLUSIONS: Loop ileostomy is easy to create and close and is associated with a low morbidity. Therefore, we recommend a defunctioning ileostomy as a procedure of choice for temporary faecal diversion for complex colorectal surgery.

Adult↗

Reconstruction after resection of tumors around the knee: role of the free vascularized fibular graft.

We present our experience with reconstruction after resection of tumors around the knee, using free vascularized fibular grafting. The study included 23 patients. The lower femur was involved in 17 cases, the upper tibia in 6. The cases included giant cell tumor of the lower femur (2 patients), giant cell tumor of the upper tibia (1 patient), malignant fibrous histiocytoma of the lower femur (1 patient), parosteal osteosarcoma (1 patient), and periosteal osteosarcoma (1 patient). The remaining patients suffered from conventional osteogenic sarcomas. The size of the defect ranged from 12 to 16 cm in length. Skin flap necrosis after tumor resection was the most common complication encountered. Other complications included peroneal nerve involvement in one case and rupture of the arterial anastomosis in another. All transferred fibulas progressed to union within 7-9 months. Union time of both upper and lower ends of the fibula and time of appearance of periosteal reaction were identical. In evaluating periosteal hypertrophy of the fibula, the hypertrophy (de Boer) index (de Boer HD, Wood MB, J Bone Joint Surg 1989;71B:374-378) proved unreliable. False positive results are obtained, when callus formation around the lower end of the femur is far more abundant than at the upper end of the fibula. For this reason, we introduced the graft index. The latter is the ratio between the diameter of the graft at its thinnest portion at latest follow-up to its diameter on the day of operation, as calculated on plain radiographs. Two of the viable fibulas developed stress fractures after plate removal. Functional and quality-of -life results were satisfactory. It is concluded that the free vascularized fibular graft remains a valuable reconstruction option after the resection of tumors around the knee, provided certain precautions are followed. First, before closure of the wound, the skin flaps should be assessed for their viability. Necrotic parts should be excised. Stable fixation is a necessary prerequisite at the time of operation. Removal of the fixation device should not be guided by union or periosteal hypertrophy, but by true widening of the medullary canal.

Adolescent↗

HLA-DO-related restriction fragment length polymorphisms in rheumatoid arthritis: evidence for a link with disease expression.

Eighty-three patients with rheumatoid arthritis (RA) were investigated for HLA-DQ and DR locus restriction fragment length polymorphisms (RFLP). Of the 83 patients, 61 (73%) possessed the DR4 allele and within this group we have investigated the relative frequencies of two DQ beta gene variants of DQw3, DQw7 and DQw8, one of which we had previously found to be raised in Felty's syndrome. This analysis revealed a significantly higher frequency of DQw7 containing haplotypes in DR4 positive rheumatoid patients (64%) than in DR-matched healthy controls (42%). Furthermore, the distribution of DQw7 was biased towards those patients with greater disability indicated by the HAQ score, more systemic disease and higher titres of rheumatoid factor, suggesting that DQw7 may contribute to disease expression.

Arthritis, Rheumatoid↗

Virological markers and antibody responses in fulminant viral hepatitis.

Clinical profiles, serological markers, and antibody responses to antigens of hepatitis B virus (HBV) were studied in patients with fulminant viral hepatitis. Whereas hepatitis A and B were found to be uncommon causes (6.9% and 12.2%, respectively), non-A, non-B (NANB) hepatitis was found to be the most common cause of fulminant hepatitis (80.9%). As against this, the incidence of hepatitis B and NANB hepatitis was very similar in nonfulminant acute viral hepatitis in adults (41.2% and 51.9%, respectively). Pregnancy with labour was an important precipitating factor for development of fulminant hepatitis of the NANB type only; 32% of fulminant NANB hepatitis patients were pregnant women and 22.6% had a history of labour preceding hepatic coma. Only 0.8% of nonfulminant NANB hepatitis cases were pregnant women. Another major precipitating factor for the development of the fulminant form of NANB hepatitis was concomitant chronic HBV carrier state. A total of 38.6% of fulminant NANB hepatitis patients were HBV carriers, whereas only 19.2% of nonfulminant acute NANB hepatitis cases were HBV carriers. Sera of 32 chronic HBV carriers with fulminant NANB hepatitis and 10 cases of fulminant hepatitis B were tested for delta antibody, and all were nonreactive. The antibody responses of the fulminant hepatitis B patients to the antigens of HBV were found to be greater compared to those of patients with nonfulminant acute hepatitis B. Antibody responses of chronic HBV carriers with fulminant NANB hepatitis to antigens of HBV were found to be depressed in comparison with those of chronic asymptomatic carriers.

Acute Disease↗