Effect of heparin surface modification in reducing silicone oil adherence to various intraocular lenses.

PURPOSE: To evaluate surface properties of various intraocular lenses (IOLs), including a newly fabricated heparin-surface-modified (HSM) silicone IOL, with special reference to their efficiency in reducing potential silicone oil adherence to the IOL optics. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Department of Ophthalmology, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Five groups of rigid and foldable IOLs were analyzed in an in vitro test for the percentage of silicone oil adherence: a single-piece foldable hydrophilic-acrylic IOL (n = 9); a single-piece rigid poly(methyl methacrylate) (PMMA) IOL with HSM coating of the lens optic (n = 9); a 3-piece foldable silicone optic IOL with HSM coating of the optic (n = 10); a single-piece standard rigid PMMA IOL (n = 7); and a standard 3-piece foldable silicone optic IOL (n = 9). After the IOLs were immersed in water and then in silicone oil, gross photographs taken. Image analysis was performed to evaluate the percentage of silicone oil coverage of the anterior and posterior surfaces of each IOL optic. RESULTS: The mean silicone oil coverage of the hydrophilic-acrylic IOLs was 5.6% +/- 2.5% (SD); of the HSM PMMA IOLs, 6.2% +/- 4.3%; of the HSM silicone optic IOLs, 6.7% +/- 3.2%; and of the standard PMMA IOLs, 20.3% +/- 13.3%. The mean silicone oil coverage was greatest on the standard silicone optic IOLs, 98.2% +/- 3.1%. CONCLUSIONS: Intraocular lenses with a hydrophilic optic have less tendency toward adherence to silicone oil than more hydrophobic designs. A foldable silicone IOL with heparin surface modification can significantly reduce potential silicone oil adherence, comparable to the level achievable with the rigid HSM PMMA designs. Two new foldable IOL styles, the HSM silicone IOL and IOLs in the general class of hydrophilic-acrylic, were highly efficacious in reducing silicone oil adherence. There is now a real choice of foldable lenses for patients with actual or potential vitreoretinal diseases.

Acrylic Resins↗

[Influence of surgery-related factors on the Nd:YAG laser capsulotomy rates of 3-piece silicone IOLs - analysis of 457 pseudophakic human globes obtained post mortem].

BACKGROUND: The purpose of this study was to analyze any possible surgical reasons which may have had caused posterior capsule opacification in 3-piece silicone IOLs that had required Nd:YAG laser treatment. Special attention was given to 1) quality of cortical clean up, 2) type of haptic fixation, and 3) continuous curvilinear capsulorhexis (CCC) size and shape. MATERIALS AND METHODS: Human eyes obtained post-mortem implanted with 3-piece silicone optic - PMMA haptic (SI 40 NB) and 3-piece silicone optic - Prolene haptic (SI 30 NB) designs IOLs, accessioned between January 1993 and December 2000 were evaluated by gross examination from behind under an operating microscope using the Miyake-Apple posterior photographic technique. The area and intensity of Soemmerring's ring and type of fixation was studied in 457 eyes. The mean diameter of the CCC and relation of the CCC edge to the optic rim were analyzed in 221 eyes. RESULTS: 1) The amount of Soemmerring's ring formation was significantly larger in the group of IOLs requiring Nd:YAG capsulotomy in both the SI 40 NB and SI 30 NB design than in the IOLs without capsulotomies. 2) The percentage of not in-the-bag fixated IOLs in both the SI 40 NB and SI 30 NB design was larger in the "Nd:YAG groups", without being statistically significant. 3) The "Nd:YAG groups" showed a significant higher amount of non overlapping clock hours of the CCC edge in relation to the optic rim. CONCLUSION: 1) The data confirm the clinical assumption that the incidence of PCO is correlated with the cortical clean up. 2) Our findings also support the clinical assumption, that poor IOL fixation increases the risk of PCO. 3) This study also verifies the relation of the CCC to PCO, namely a relatively small CCC covering the entire optic rim is best to reduce the Nd:YAG laser rate.

Cataract↗

[Postoperative opacification of posterior chamber intraocular lenses - a review].

Postoperative opacification of intraocular lenses (IOLs) is a very unpleasant complication for the ophthalmic surgeon and the patient. We report on our experiences with opacification of different foldable IOL designs and rigid poly (methyl methacrylate) (PMMA) posterior chamber lenses.1. Snowflake degeneration of PMMA IOLs: This condition is an unanticipated and surprising late postoperative finding 8 to 15 years after implantation. In our opinion, this complication is probably not related to the PMMA biomaterial itself, but rather it appears to represent a manufacturing problem that has affected a selected, albeit large number of lenses manufactured in the 1980s-mid 1990s.2. Degeneration of UV absorber material and calcium deposits within the optic of hydrophilic IOLs: Two years postoperatively degenerations of UV absorber material and calcium deposits within the optic of single piece hydrophilic acrylic lenses SC60B-OUV manufactured by MDR (Medical developmental research Inc. Clearwater FL, USA) can occur. Although the precise mechanism is not fully known, it was assumed that these opacifications are due to premature aging of the UV blocking agent incorporated in the lens biomaterial and calcification.3. Calcification on the surface of the Bausch & Lomb Hydroviewtrade mark IOLs: Twelve to 15 months postoperatively granular surface calcifications in Hydroviewtrade mark IOLs occured. The mechanism is not fully understood. According to Bausch and Lomb studies, part of the components of the packaging contained silicone, which may have come off the packaging onto the lens optic, where it then appears to be a catalyst for calcium precipitation. The manufacturer has correlated a change in packaging with the appearance of the opacification. The manufacturer now believes that this problem has been solved. However, final verification will require a careful 1 - 2 years clinical study.4. Glistenings in the hydrophobic acrylic AcrySoftrade mark IOLs: The time frame of glistenings in the AcrySoftrade mark IOLs is highly variable. It has been suggested that the occurrence of glistenings may be related to variations in the temperature of the lens just prior to and or during insertion into the eye. Formation of vacuoles may occur within the submersed acrylic polymer when there is a transient increase and then decrease in temperature during the surgical procedure. "Glistenings" may then subsequently form by ingress of anterior chamber fluid. Contrast sensitivity can been decreased in some patients, but clinically significant decrease of visual acuity has been rare.

Biocompatible Materials↗

[Millenniums update on posterior capsule opacification (PCO) scores, centration, biocompatibility and fixation of foldable intraocular lenses (IOL) - an analysis of 1,221 pseudophakic post mortem globes].

BACKGROUND: The ongoing and fast evolution of foldable IOL designs established the necessity to evaluate the different abilities of each lens style. The large IOL database (over 16,500 specimens) acquired in our laboratory, has permitted us to perform a clinico-pathological analysis on pseudophakic autopsy globes provided from sources worldwide, especially many Lions Eye banks in the United States. MATERIAL AND METHODS: We analyzed 6 foldable IOL styles commonly implanted in the United States, using one type of rigid IOL design (1-piece design rigid PMMA optics) as a comparison group. Posterior capsule opacification (PCO) score, decentration, fixation, presence or absence of a Nd:YAG laser posterior capsulotomy and area and intensity of Soemmerring's ring formation was discerned by examination under an operating microscope using the Miyake-Apple posterior photographic technique. RESULTS: The four lenses with the lowest rates ranging between 3.8 % and 21.7 % are modern designs, mostly implanted after 1992. The two lenses with the higher rates ranging between 23.1 % and 30.4 %, were all older designs, already prevalent prior to 1992. IOL fixation with both haptics in the capsular bag showed the best centration values and PCO scores. Our studies to date have shown in a preliminary fashion that the AcrySoftrade mark IOL displays the the lowest (best) biocompatibility score. CONCLUSIONS: Entering the new millenium, with evolution of modern surgical techniques and IOL designs, the incidence of the two major complications of cataract surgery, decentration and PCO are now finally diminishing.

Autopsy↗