PubMed Health⌕ Search

Biomedical subjects

S N Vaslef

Publications and source records attributed to S N Vaslef.

20 records · Page 2Linked to original sources

Enhanced oxygen delivery induced by perfluorocarbon emulsions in capillary tube oxygenators.

Previous studies showed that a new generation of perfluorocarbon (PFC) emulsions increased tissue PO2 in the cat retina to a degree that could not be explained by the small increase in arterial O2 content seen after the infusion of low doses of 1 g PFC/kg body weight. It seems that increased O2 delivery at the tissue level after PFC infusion is caused by a local effect in the microcirculation. The authors studies this effect in vitro at steady state in a closed loop circuit, consisting of one of two types of capillary tube oxygenators, deoxygenator(s), a reservoir bag filled with anticoagulated bovine blood or saline (control), and a roller pump, to see if the addition of PFC would have an effect on the PO2 difference (delta PO2) across the capillary tube membrane oxygenator at a blood flow rate of 3 l/min. Perfluorocarbon was added in three incremental doses, each giving about 0.7 vol% of PFC. The delta PO2 across the oxygenator was measured before and after each dose. The mean percent increases in delta PO2 in blood for two types of oxygenators were 19.2 +/- 8% (mean +/- SD, n = 6, P = 0.002) and 9.9 +/- 4% (n = 3, P = 0.05), respectively, whereas the mean percent change in delta PO2 in saline was -4.9 +/- 2% (n = 2, P = 0.2). Inlet PO2s to the oxygenator were only minimally increased. The authors conclude that O2 delivery was significantly enhanced after injection of PFC in blood in this capillary tube model. A near wall excess of PFC particles may account for the augmentation of O2 diffusion in this model.

Animals↗

Use of a mathematical model to predict oxygen transfer rates in hollow fiber membrane oxygenators.

A semi-empirical theoretical model of oxygen transfer is used to predict the rates of oxygen transfer to blood in hollow fiber membrane oxygenators over a wide range of inlet conditions. The predicted oxygen transfer rates are based on performance of the devices with water, which is more cost effective and easier to handle than blood for in vitro evaluations. Water experiments were conducted at three different flow rates to evaluate oxygen transfer performance in three commercially available membrane oxygenators. Data obtained from these experiments were used in a computer model to predict the rate of oxygen transfer to bovine blood at specified inlet conditions. Blood experiments were conducted at three different flow rates at a wide variety of inlet conditions, including different pH levels, hemoglobin concentrations, and oxyhemoglobin saturations for the three types of oxygenators. The measured and predicted oxygen transfer rates are closely correlated, which suggests that we have an accurate, reliable method for predicting oxygen transfer in hollow fiber membrane lungs.

Animals↗