PubMed Health⌕ Search

Biomedical subjects

S Neumaier

Publications and source records attributed to S Neumaier.

11 recordsLinked to original sources

The second EURADOS intercomparison of national network systems used to provide early warning of a nuclear accident.

In 1999 and 2002, the EURADOS Working Group on Environmental Monitoring organised two European intercomparison exercises of national network systems used to provide early warning in case of a nuclear accident. In total, 12 European countries, represented by more than 40 scientists, participated in these two intercomparisons with more than 35 different dose rate detectors. In addition, an in situ gamma spectrometry intercomparison was performed by a group of European scientists during the 2002 exercise. Results of these spectrometry measurements will be reported elsewhere. This report summarises the results of the second intercomparison, performed in 2002, at the environmental dosimetry facilities of the Physikalisch-Technische Bundesanstalt (PTB) in Germany. The unique combination of the ultra-low background Underground Laboratory (UDO) and two free-field sites (a floating platform on a lake showing an almost pure cosmic radiation field and a free-field gamma ray irradiation facility) provide the particular opportunity to precisely quantify the inherent background of the detectors and to calibrate them almost free of any background and traceable to PTB's primary standards. In addition, the intercomparison comprised investigations on the energy and dose rate dependence of the detectors' response to gamma radiation as well as on the response to cosmic radiation. Finally, the sensitivity of the detector systems to small dose rate variations, similar to that caused by a passing overhead radioactive plume, was studied under realistic free-field conditions. Following the Council Directive 96/29/EURATOM, the participants of the 2002 intercomparison were asked to report their results in terms of the operational quantity ambient dose equivalent, H(*)(10). Although the verification of the individual calibrations showed smaller discrepancies than those in the 1999 intercomparison, in a few cases, these discrepancies would be still unacceptably high in the case of a real emergency situation as demonstrated by the plume results. This shows the clear need for further efforts towards a European harmonisation in environmental dosimetry. For this purpose, a further intercomparison shall be held at the PTB in 2006, especially with the participation of new members of the European Union.

Air Pollution, Radioactive↗

Measurements of 60Co in spoons activated by neutrons during the JCO criticality accident at Tokai-mura in 1999.

Neutron activated items from the vicinity of the place where the JCO criticality accident occurred have been used to determine the fluence of neutrons around the facility and in nearby residential areas. By using underground laboratories for measuring the activation products, it is possible to extend the study to also cover radionuclides with very low activities from long-lived radionuclides. The present study describes gamma-ray spectrometry measurements undertaken in a range of underground laboratories for the purpose of measuring (60)Co more than 2 years after the criticality event. The measurements show that neutron fluence determined from (60)Co activity is in agreement with previous measurements using the short-lived radionuclides (51)Cr and (59)Fe. Limits on contamination of the samples with (60)Co are evaluated and shown to not greatly affect the utility of neutron fluence determinations using (60)Co activation.

Chromium Radioisotopes↗

Lessons learnt from an international intercomparison of national network systems used to provide early warning of a nuclear accident.

As part of the European Research Council's Fourth Framework Programme, the EURADOS Action Group on Monitoring of External Exposures held an intercomparison of national network systems. This took place during May/June 1999 at the Risø Natural Enviromental Radiation Measurement Station in Denmark and at the Underground Laboratory for Dosimetry and Spectrometry (UDO) of the Physikalisch-Technische Bundesanstalt (PTB) in Germany. The network systems are used continuously to monitor radiation levels throughout a country in order to give early warning of nuclear accidents having transboundary implications. The radiation levels measured are used to estimate the radiation risks to people arising from the accident. Seven European countries participated in the intercomparison with detector systems used in their national network systems as well as with detectors being developed for future use. Since different radiation quantities were measured by the systems (namely exposure, air kerma and ambient dose equivalent), the initial analysis of the intercomparison results was made in terms of the quantity air kerma rate. This report completes the analysis of the results and these are given in terms of air kerma rate in order to be consistent with the preliminary report. In addition, in some cases the results are also given in terms of the quantity measured by each national network system. The experience gained from this intercomparison is used to help organise a follow-up intercomparison to be held at the PTB Braunschweig in September 2002 and in which a further seven or eight countries from Europe will participate.

Air Pollution, Radioactive↗

Experience in long-term neutron dose equivalent measurements using etched track detectors with (n,alpha) converters in moderators.

Etched track Makrofol detectors combined with Kodak BN-1 boron (n,alpha) converters were used inside a 30 cm diameter polyethylene (PE) sphere for the measurement of the neutron ambient dose equivalent. We found unexpectedly high values for the neutron dose equivalent of about 250 microSv instead of 25 microSv for 3 months' exposure in the natural environment. Results from such detectors etched in the authors' labortories revealed that the tracks could only be induced by spontaneous particle emission from the converter. This was confirmed by track diameter analysis and additional special etching of deeper detector layers. Eight surface barrier detectors were used simultaneosly for several days to measure the alpha spectra of the converters. The overall count rate in the energy range 2.5-7.5 MeV was 10 alpha particles d(-1) x cm(-2) for most of the converters and about 10 times less than this for some of them. To identify the nuclides responsible for alpha emission within the converters, gamma spectra of converters were measured for 8 days using a highly sensitive low-background gamma spectrometry system The spectra clearly indicated a small contamination (10 +/- 3 mBq) of the converter foils with 225Ra (T(1/2) = 5.7 y) typically originating from 232Th.

Alpha Particles↗

Risk factors, outcome, and treatment in subtypes of ischemic stroke: the German stroke data bank.

BACKGROUND AND PURPOSE: Data on risk factors for etiologic subtypes of ischemic stroke are still scant. The aim of this study was to characterize stroke subtypes regarding risk factor profile, outcome, and current treatment strategies. METHODS: We analyzed data from 5017 patients with acute ischemic stroke (42.4% women, aged 65.9+/-14.1 years) who were enrolled in a large multicenter hospital-based stroke data bank. Standardized data assessment and stroke subtype classification were used by all centers. RESULTS: Sex and age distribution, major risk factors and comorbidities, recurrent stroke, treatment strategies, and outcome were all unevenly distributed among stroke subtypes (P<0.001, respectively). Cardioembolism, the most frequent etiology of stroke (25.6%), was particularly common in the elderly (those aged >70 years) and associated with an adverse outcome, a low rate of early stroke recurrence, and frequent use of thrombolytic therapy and intravenous anticoagulation. Large-artery atherosclerosis (20.9%), the most common cause of stroke in middle-aged patients (those aged 45 to 70 years), showed the highest male preponderance, highest rate of early stroke recurrence, and highest prevalence of previous transient ischemic attack, current smoking, and daily alcohol consumption among all subtypes. The highest prevalence of hypertension, diabetes mellitus, hypercholesterolemia, and obesity was found in small-vessel disease (20.5%), which, in turn, was associated with the lowest stroke severity and mortality. CONCLUSIONS: Our results foster the concept of ischemic stroke as a polyetiologic disease with marked differences between subtypes regarding risk factors and outcome. Therefore, studies involving risk factors of ischemic stroke should differentiate between etiologic stroke subtypes.

Adult↗

The PTB underground laboratory for dosimetry and spectrometry

In 1991, the Physikalisch-Technische Bundesanstalt established an underground laboratory for dosimetry and spectrometry (UDO) at the Asse salt mine, near Braunschweig. Due to the depth of 925 m below ground (equivalent to about 2100 m of water), the cosmic ray muon intensity in this facility is reduced by more than 5 orders of magnitude. In addition, the low specific activity of the pure rock salt and a low concentration of radon lead to an extremely low ambient dose equivalent rate of less than 1 nSv/h. The UDO facility is therefore well suited for dosimetry at very low dose rates, as well as for Ultra-Low-Background (ULB) gamma-ray spectrometry. In 1998, a coaxial low-background HPGe-detector (88% relative efficiency, FWHM 2.0 keV at 1.33 MeV) with an extended shielding (20 cm low-activity lead, 1 cm electrolytic copper, N2-flushing) was installed at UDO; the count rate per mass of germanium, integrated over the energy range from 40 to 2750 keV, was measured to be 0.012 s(-1) kg(-1). Results from test measurements and first applications are reported. The design of a ULB gamma-detector system, presently under construction, is described.

Journal Article↗

Retinal ganglion cell layer and visual function in a patient with optic disc drusen.

BACKGROUND: To correlate the retinal ganglion cell pattern to visual acuity and visual field data in a patient with bilateral optic disc drusen, a quantitative clinicopathological study was carried out. METHODS: Both retinae of a patient with optic drusen were whole-mounted. Retinal ganglion cell counts were made using a sampling scheme covering the whole retina and compared to the findings in 10 normal retinae. Relative ganglion cell reduction in the drusen retinae was correlated to clinical data. RESULTS: The total retinal ganglion cell count was reduced from 1244858+/-98736 in normal retinae to 305319 on the right and 527571 on the left eye with optic disc drusen. Large ganglion cells had a better chance of survival. Parafoveal ganglion cell loss was 57% for the right and 36% for the left eye, while visual acuity was 0.8 and 1.0 respectively. The mean light sensitivity loss increased from the centre (6.2 dB) to paracentral (9.9 dB), mid-peripheral (13.7 dB) and outer peripheral (15.0 dB) retina, while ganglion cell losses were smallest in outer peripheral retina (21.9%), followed by central (53.0%), mid-peripheral (70.9%) and paracentral retina (87.7%). CONCLUSION: These data validate Frisén's theory on central retinal resolution and provide the structural basis for the clinical rule that low visual acuity should not be attributed to disc drusen. Automated light sense perimetry gives an inadequate picture of retinal damage caused by optic disc drusen.

Adolescent↗

Underground measurements of radioactivity.

The exceptional sensitivity of gamma-ray spectrometry in underground laboratories has increasing application because of the important science and technology that it allows to be studied. Early work focused on rare fundamental phenomena, e.g. double beta decay, but a growing number of underground measurements is being performed in fields such as environmental monitoring, surveillance of nuclear activities, benchmarking of other physical techniques and materials selection for equipment which require materials with extremely low levels of radioactivity. This report describes the state of the art in underground gamma-ray spectrometry. Backgrounds of HPGe-detectors at various underground laboratories are presented and compared. Improved techniques and detectors are described and needs of deep underground facilities for higher sensitivity measurements are discussed.

Journal Article↗