PubMed Health⌕ Search

Biomedical subjects

S O Schoenberg

Publications and source records attributed to S O Schoenberg.

At least 19 recordsLinked to original sources

Quantitative and qualitative characterization of vascularization and hemodynamics in head and neck tumors with a 3D magnetic resonance time-resolved echo-shared angiographic technique (TREAT)--initial results.

The purpose of this paper is to characterize and quantify the vascularization and hemodynamic characteristics of head and neck tumors (HNT) with a dynamic 3D time-resolved echo-shared angiographic technique (TREAT) using the regular contrast agent (CA) bolus. Sixteen patients with HNT underwent 3D-TREAT during the CA administration on a 1.5-T magnetic resonance (MR) scanner. Using a parallel imaging acceleration factor of 2, 20 3D data sets at a temporal resolution of 2.3 s/frame were acquired. The quality of tumor delineation, vascularization type, and enhancement pattern were evaluated. Quantitative assessment included measurement of the contrast-to-noise ratio (CNR), determination of signal-intensity-over-time (SIT) curves, time-to-peak enhancement within the carotid arteries and the tumor, and the delay between both. TREAT was compared to conventional digital subtraction angiography (DSA) in six patients. Tumor delineation with TREAT was very good or good in 11/16 patients, and better with TREAT than with DSA in 3/6 cases. The CNR was significantly different for glomus tumors versus hypovascularized malignant tumors with TREAT (p=0.0001), but not on T1-weighted gradient echo (T1w GE) images. Qualitative assessment of tumor vascularization on dynamic TREAT shows good correlation (r=0.75) to quantitative SIT curves. We conclude that TREAT imaging permits the characterization of tumor vascularity and holds promise as a supplementary diagnostic tool in the differential diagnosis of HNT.

Adolescent↗

High-grade stenoses of the internal carotid artery: comparison of high-resolution contrast enhanced 3D MRA, duplex sonography and power Doppler imaging.

PURPOSE: The objective of this study was to determine the agreement and diagnostic accuracy of high-resolution contrast enhanced magnetic resonance angiography (MRA) with integrated parallel acquisition techniques (iPAT), color coded duplex ultrasound (CCDS) and power Doppler ultrasound (PD) in the assessment of high-grade stenoses of the internal carotid artery (ICA). METHODS: Forty-four patients with 52 known or suspected stenoses of the internal carotid artery (ICA) were included in this prospective study. High-resolution MRA scans with a spatial resolution of 0.9 mm x 0.7 mm x 0.9 mm were acquired with an iPAT acceleration factor of 2 on a 1.5T MR system (Sonata Maestro Class, Siemens Medical Solutions, Erlangen, Germany) with a head, neck and body coil. For the 3D-CE MRA a fast spoiled gradient echo sequence (FLASH) was used. To compensate for the inherent signal loss with parallel imaging, a 1M contrast agent (gadobutrol, Gadovist, Schering, Berlin, Germany) was used. Stenoses were quantified by two readers in consensus in cross-sectional area measurements and graded according to the NASCET criteria. Using color coded duplex ultrasound (CCDS) and power Doppler (PD; Logiq 9, GE), the stenoses were also graded by two readers in consensus according to the NASCET criteria from intra- and post-stenotic diameter measurements. The results of MRA, CCDS and PD were compared to intraoperative findings or to follow-up examinations. RESULTS: High-resolution MRA allowed an excellent grading of vascular stenoses. In 70-90% degrees of stenosis there was an underestimation of the degree of stenosis in MRA as well as in CCDS. However, there was an overestimation of 90% stenoses in both MRA and CCDS. Pseudoocclusions with a lumen of less than one millimeter were occasionally rated as a complete occlusion in MRA. CONCLUSION: A combination of MRA and duplex sonography seems reasonable for the accurate grading of stenoses and determination of distal stenoses downstream. However, the accuracy of duplex ultrasound depends on the examiner's experience.

Aged↗

Functional renal imaging: nonvascular renal disease.

Functional renal imaging-a fast-growing field of MR-imaging-applies different sequence types to gather information about the kidneys other than morphology and angiography. This update article presents the current status of different functional imaging approaches and presents current and potential clinical applications. Apart from conventional in-phase and opposed-phase imaging, which already yields information about the tissue composition, BOLD (blood-oxygenation level dependent) sequences, DWI (diffusion-weighted imaging) sequences, perfusion measurements, and dedicated contrast agents are used.

Contrast Media↗

[Oxygen-enhanced MRI of the lung: optimized calculation of difference images].

BACKGROUND: In oxygen-enhanced lung MRI, difference maps of acquisitions during inhalation of room air and pure oxygen are calculated to assess lung function. The purpose of this study was to analyze how the calculation of these difference maps depends on the delayed signal change after switching the gas supply. METHODS: Ten healthy volunteers were examined with an ECG and respiratory-triggered T1-weighting inversion recovery HASTE sequence with parallel imaging. Four blocks with 20 repetitions of up to 6 coronal slices were continuously acquired; in blocks 1 and 3 room air was supplied, in blocks 2 and 4 oxygen. Data were postprocessed, discarding between 0 and 19 repetitions after each change of gas supply before calculating the relative signal difference. RESULTS: The averaged relative signal difference increases from 9.4 to 17.4% when the number of discarded acquisitions increases; the ratio of signal difference and spatial standard deviation reaches a maximum at 5-8 discarded acquisitions. CONCLUSIONS: An optimized ratio of signal difference and statistical error is found if about 5-8 of 20 respiratory-triggered repetitions are discarded after each change of gas supply for the calculation of difference maps.

Adult↗

[MRI of pulmonary perfusion].

Lung perfusion is a crucial prerequisite for effective gas exchange. Quantification of pulmonary perfusion is important for diagnostic considerations and treatment planning in various diseases of the lungs. Besides disorders of pulmonary vessels such as acute pulmonary embolism and pulmonary hypertension, these also include diseases of the respiratory tract and lung tissue as well as pulmonary tumors. This contribution presents the possibilities and technical requirements of MRI for diagnostic work-up of pulmonary perfusion.

Humans↗

[Comparison of 2D and 3D sequences for MRCP. Clinical value of the different techniques].

Magnetic resonance cholangio-pancreaticograpy (MRCP) is a non-invasive imaging modality of the pancreatico-biliary system which plays an increasingly important role in the clinical and diagnostic workup of patients with biliary or pancreatic diseases. The present review is designed to give an overview of the currently available and appropriate sequences, their technical background, as well as new developments and their relevance to the various clinical issues and challenges. The impact of the latest technical innovations, such as integrated parallel imaging techniques and navigator-based respiratory triggering, on the diagnostic capacities of MRCP is discussed. In this context, the individual value of RARE, T2w single shot turbo/fast spin echo (SSFSE) and the recently introduced 3D T2w turbo/fast spin echo sequences (T2w 3D-T/FSE) is reviewed. RARE imaging may be preferred in severely ill patients with limitations in cooperation, SSFSE is particularly effective in differentiating benign and malignant stenosis, and 3D-FSE offers additional advantages in the detection of small biliary concrements.

Adult↗

Whole-body MR imaging of bone marrow.

In clinical routine, multimodality algorithms, including X-ray, computed tomography, scintigraphy and MRI, are used in case of suspected bone marrow malignancy. Skeletal scintigraphy is widely used to asses metastatic disease to the bone, CT is the technique of choice to assess criteria of osseous destruction and bone stability. MRI is the only imaging technique that allows direct visualization of bone marrow and its components with high spatial resolution. The combination of unenhanced T1-weighted-spin echo- and turbo-STIR-sequences have shown to be most useful for the detection of bone marrow abnormalities and are able to discriminate benign from malignant bone marrow changes. Originally, whole-body MRI bone marrow screening was performed in sequential scanning techniques of five body levels with time consuming coil rearrangement and repositioning of the patient. The introduction of a rolling platform mounted on top of a conventional MRI examination table facilitated whole-body MR imaging and, with the use of fast gradient echo, T1-weighted and STIR-imaging techniques, for the first time allowed whole-body imaging within less than one hour. With the development of parallel imaging techniques (PAT) in combination with global matrix coil concepts, acquisition time could be reduced substantially without compromises in spatial resolution, enabling the implementation of more complex and flexible examination protocols. Whole-body MRI represents a new alternative to the stepwise multimodality concept for the detection of metastatic disease, multiple myeloma and lymphoma of the bone with high diagnostic accuracy.

Bone Marrow Neoplasms↗

[Estimation of diffuse bone marrow infiltration of the spine in multiple myeloma: correlation of MRT with histological results].

PURPOSE: To determine the detection of diffuse bone marrow infiltration with MRI in comparison with histopathological findings. MATERIALS AND METHODS: MRI was performed on 45 patients with histologically proven multiple myeloma and on 30 healthy individuals. Three experienced radiologists read separately Tl-weighted SE sequences, STIR sequences and the combination of Tl-weighted SE and STIR sequences of the spine. Additionally, Tl-weighted SE sequences were obtained after gadolinium administration and the percentage increase in signal intensity was calculated. Bone marrow histology was used as gold standard for assessing the grade of infiltration. A dichotomous decision (infiltration yes/no) was made when assessing the MRI examinations. RESULTS: For the visual detection of diffuse infiltration, the best sensitivity was found with Tl-weighted SE sequences, achieving 71 % on average. The specificity was 89 %. The STIR sequences showed a sensitivity of 61 % and a specificity of 98 %, and the combination of Tl-weighted/STIR-sequences achieved a sensitivity of 65 % and a specificity of 94 %. In comparison with the histological findings, the sensitivity of the Tl-weighted sequences was 35 % for low-grade, 89 % for moderate and 100 % for high-grade infiltration. The application of contrast material with calculation of the percentage signal increase improved the detection by 7 %. CONCLUSION: The sensitivity of the visual detection of diffuse multiple myeloma with unenhanced MRI is limited for low-grade or moderate infiltration, whereas the sensitivity for high grade infiltration is reliable. The specificity is high and the diagnostic confidence improves after application of contrast material with calculation of the percentage increase in signal intensity.

Adult↗

The feasibility of spatial high-resolution magnetic resonance angiography (MRA) of the renal arteries at 3.0 T.

PURPOSE: To evaluate the feasibility of high-spatial resolution magnetic resonance angiography (MRA) of the renal arteries at 3.0 T. MATERIAL AND METHODS: Twelve healthy volunteers (mean age, 38.8 years) underwent renal MRA at 3.0 T. The application of parallel imaging with an acceleration factor of 3 allowed obtaining MR angiographic data with a voxel size of 0.9 x 0.8 x 0.9 mm in scan time of only 16 s. A dose of 0.2 mmol/kg body weight of 0.5-molar gadodiamide was administered at a flow rate of 2 ml/s. For image analysis, image quality, presence of artifacts, venous contamination and level of noise were rated by two radiologists in consensus. RESULTS: All examinations were of diagnostic quality. The image quality was rated good or very good in 91 % (11/12) of cases. Due to the high parallel imaging factor the level of noise was slightly increased without diagnostic impairment. Mild venous enhancement was found in 75 % (9/12) of the examinations. CONCLUSION: Renal MRA at 3.0 T is feasible with high spatial resolution and a short acquisition time.

Adult↗

Brain metastases in metastatic non-small cell lung cancer responding to single-agent gefitinib: a case report.

Brain metastases are a frequent finding in patients with non-small cell lung cancer (NSCLC). The present case reports the clinical course of a patient who was treated with gefitinib alone for progressive brain metastases after whole-brain irradiation treatment (WBRT). A 50-year-old women with primary stage IV NSCLC (bone metastases) developed brain metastases after 3 cycles of chemotherapy consisting of paclitaxel and carboplatin (CBDA). After completion of the WBRT, magnetic resonance imaging (MRI) indicated further progression. Two cycles of temozolomide and topotecan were applied; this was ineffective in preventing central nervous system progression. For symptomatic brain metastatic disease the patient received gefitinib as single-agent treatment. Within a few weeks of treatment there was an obvious clinical improvement. Follow-up of the brain 2 months after the start of treatment showed a decrease in both the size and number of brain metastases. Additional manifestations in the lungs and the skeletal system were re-assessed as stable disease during the treatment with gefitinib. Within 4 months of treatment there were no side-effects such as skin rash or any other systemic toxicity. Gefitinib may therefore have a role in the treatment of brain metastases from NSCLC.

Antineoplastic Agents↗

Perfusion CT in patients with advanced bronchial carcinomas: a novel chance for characterization and treatment monitoring?

Advanced bronchial carcinomas by means of perfusion and peak enhancement using dynamic contrast-enhanced multislice CT are characterized. Twenty-four patients with advanced bronchial carcinoma were examined. During breathhold, after injection of a contrast-medium (CM), 25 scans were performed (1 scan/s) at a fixed table position. Density-time curves were evaluated from regions of interest of the whole tumor and high- and low-enhancing tumor areas. Perfusion and peak enhancement were calculated using the maximum-slope method of Miles and compared with size, localization (central or peripheral) and histology. Perfusion of large tumors (> 50 cm3) averaged over both the whole tumor (P = 0.001) and the highest enhancing area (P = 0.003) was significantly lower than that of smaller ones. Independent of size, central carcinomas had a significantly (P = 0.04) lower perfusion (mean 27.9 ml/min/100 g) than peripheral ones (mean 66.5 ml/min/100 g). In contrast, peak enhancement of central and peripheral carcinomas was not significantly different. Between non-small-cell lung cancers and small-cell lung cancers, no significant differences were observed in both parameters. In seven tumors, density increase after CM administration started earlier than in the aorta, indicating considerable blood supply from pulmonary vessels. Tumor perfusion was dependent on tumor size and localization, but not on histology. Furthermore, perfusion CT disclosed blood supply from both pulmonary and/or bronchial vessels in some tumors.

Adult↗

[Determining global heart function with real time TrueFISP in one respiratory cycle].

Real-time multislice cine techniques lead to inaccurate results in ventricular volumes based on limited temporal resolution. The purpose of the study is to evaluate a real-time cine technique with parallel imaging algorithms in comparison to standard segmented techniques. Twelve patients underwent cardiac cine MRI using real-time multislice cine trueFISP. Temporal resolution was improved using parallel acquisition techniques (iPAT) and data acquisition was performed in a single breath-hold along the patients' short axis. Evaluation of EDV, ESV, EF and myocardial mass was performed and results compared to a standard segmented single-slice cine trueFISP. Combination of real-time cine trueFISP and iPAT provided a temporal resolution of 48 ms. Results of the multislice approach showed an excellent correlation to standard single-slice trueFISP for EDV (0.94, p <0.001), ESV (0.97, p <0.001) EF (0.99, p <0.001) and myocardial mass (0.93, p <0.001). No significant differences could be found. The use of parallel acquisition techniques (PAT) allow for a substantial improvement of temporal resolution in real-time cine MRI (<50 ms). Therefore these techniques enable an accurate and exact quantification of global ventricular function.

Algorithms↗

[Cardiovascular whole body MRI with parallel imaging].

PURPOSE: To create a whole-body cardiovascular MRI protocol with parallel imaging (iPAT). MATERIAL AND METHODS: Twenty two persons participated in the whole body scan. Due to iPAT high resolution imaging of the heart could be performed. 3D contrast enhanced MR angiography (3D-CE-MRA) took only 62 s to cover the whole body at a spatial resolution of less than 1.4x1.0x1.5mm(3). Scan time for HASTE lung imaging could be reduced by the factor of 2 while maintaining the signal to noise ratio (SNR). Image quality was rated by 2 radiologists blinded to each other. RESULTS: Mean scan time was 104 min on the standard system and less than 80 min on the new system. 75% of all MRA segments were rated good in terms of vessel conspicuity, more than 80% had no venous overlay. One case of distal occlusion of the anterior tibial artery and two cases of myocardial infarction were detected. CONCLUSION: Parallel imaging offers the possibility of fast whole body imaging. A combination of morphologic and functional imaging can be performed within less than 80 min.

Adult↗

[Comparison of high resolution whole-body MRI using parallel imaging and PET-CT. First experiences with a 32-channel MRI system].

PURPOSE: To compare the accuracy in the detection and staging of various malignant tumors with high resolution whole-body MRI using parallel imaging with whole-body dual-modality PET-CT. PATIENTS AND METHODS: Preliminary results of an interim analysis from a prospective, blinded study are presented, in which 20 patients (mean age 59 years, range 27-77 years) with different oncological diseases underwent whole-body dual modality FDG-PET-CT screening for tumor search or staging in case of confirmed or suspected metastatic disease. All patients also underwent whole-body MRI imaging with the use of parallel imaging (iPAT). High-resolution coronal T1w- and STIR-sequences of 5 body levels with 512 x 512 matrix, axial fast T2w imaging of lung and abdomen (HASTE), contrast-enhanced dynamic and static T1w-sequences of liver, brain, abdomen, and pelvis were performed. Using a 32-channel whole-body MRI scanner (Magnetom Avanto, Siemens Medical Solutions) with a total field of view of 205 cm and free table movement, all patients could be covered from head to toe within one examination. With this technique, high spatial resolution and acceptable scanning times could be obtained. Two experienced radiologists read the MRI-scans, one radiologist and one nuclear scientist read PET-CT scans, each in consensus in a clinical setting. Delineation of the primary tumor (T-stage) or recurrent tumor, pathologic lymph node involvement, as well as degree and localization of metastatic disease, was assessed using PET-CT as standard of reference. RESULTS: Metastases from gastrointestinal tumor (25%) and breast cancer (25%), genitourinary tumor (15%) and malignant melanoma (15%) were detected. In 4/20 patients the primary tumor was identified, 2/20 patients showed recurrent tumor. Of 140 malignant lesions detected by PET-CT, 124 lesions were detected with MRI, resulting in a sensitivity of 89% at a specificity of 86%. In malignant lymph node detection, sensitivity of MRI was 83% and specificity 85%. CONCLUSION: Whole-body MRI is a promising technique in the detection of primary tumor and metastatic disease. Sensitivity in the assessment of lymph node metastases seems to be limited. With the use of parallel imaging (iPAT), dedicated high-resolution whole-body MRI is possible within acceptable scanning times.

Adult↗

[The significance of MR angiography for the diagnosis of carotid stenoses].

Arteriosclerosis of the supra-aortic vessels is a known risk factor for cerebrovascular disease. Large multicenter studies like NASCET and ECST have proven the protective effects of the surgical treatment of severe (>70%) carotid artery stenoses. The exact detection and grading of stenoses of the carotid arteries is a prerequisite for a successful therapy. Besides the gold-standard examination, digital subtraction angiography (DSA), MR angiography (MRA) is being used increasingly. MRA allows a non-invasive, high-resolution depiction of the supra-aortic vessels without ionizing radiation in only 20 s. This article first illustrates the MRA-techniques, and the indications and limitations of MRA. Next, the diagnostic accuracy of MRA is compared to DSA and ultrasound. The clinical value of MRA for the detection of stenoses of the carotid arteries is discussed on the basis of clinical examples.

Angiography, Digital Subtraction↗

[Modern visualization of the liver with MRT. Current trends and future perspectives].

This contribution provides an overview and imparts basic knowledge on pertinent technical developments in magnetic resonance imaging (MRI) of the liver: 3D sequences, respiratory triggering, parallel imaging, and 3 Tesla (3T). 3D sequences can be used as T1-weighted (T1w) sequences for analyzing dynamics of contrast enhancement or as T2w sequences for MR cholangiography. Consistent improvements in respiratory triggering make it possible to obtain good image quality on T2w scans even in patients unable to hold their breath. Parallel imaging as a universal technique to accelerate image acquisition is particularly appropriate for MRI of the liver, and it has been shown that the reduced acquisition time is not achieved at the expense of image quality. Further progress in MRI of the liver can be expected with use of the 3T systems, but hitherto irrelevant problems must still be solved. Overall the innovations presented here, applied alone or in combination, facilitate rapid, robust, and high-quality MRI diagnostic assessment of the liver.

Algorithms↗

Crohn disease of the small bowel proximal to the terminal ileum: detection by MR-enteroclysis.

BACKGROUND: Although Crohn disease (CD) can affect the entire alimentary tract, the proportion of patients with small-bowel inflammation proximal to the terminal ileum is still unclear. Magnetic resonance imaging (MRI) combined with small-bowel enteroclysis can detect inflammatory lesions of the small bowel. Hence, we applied MR-enteroclysis to assess the percentage of patients with small-bowel inflammation proximal to the terminal ileum among patients with CD and abdominal pain. METHODS: Twenty-five consecutive patients with low, active CD of the colon and/or terminal ileum and episodes of abdominal pain were examined by both MR-enteroclysis and conventional enteroclysis. The findings of MR-enteroclysis were compared with endoscopic and histological results in the terminal ileum and conventional enteroclysis in the small bowel proximal to the terminal ileum. RESULTS: In 13 of the 25 patients, inflammation of the small bowel proximal to the terminal ileum was shown by MR-enteroclysis, whereas in only 4 of the 25 patients, signs of inflammation of the small bowel proximal to the terminal ileum were shown by conventional enteroclysis, all of which were demonstrated by MR-enteroclysis. MR-enteroclysis confirmed the findings in 22 of 25 patients in whom endoscopy and histology had shown inflammation (16 of 18) or no inflammation (6 of 7) of the terminal ileum. CONCLUSION: In symptomatic patients with CD even of low activity, inflammation of the small bowel proximal to the terminal ileum is frequent.

Adult↗

[Radiologic diagnostics of dementia].

Dementia is one of the most common diseases in the elderly population and is getting more and more important with the ageing of the population. A radiologic structural examination with CT or MRI is meanwhile a standard procedure in the diagnostic work up of patients with dementia syndrome. Radiology enables an early diagnosis and a differential diagnosis between different causes of dementia. Because structural changes occur only late in the disease process, a more detailed structural analysis using volumetric techniques or the use of functional imaging techniques is mandatory. These days, structural imaging uses MRI which enables to detect early atrophic changes at the medial temporal lobe with focus on the amygdala hippocampal complex. These changes are also present in the normal ageing process. In patients with Alzheimer's disease, however, they are more rapid and more pronounced. The use of functional imaging methods such as perfusion MRI, diffusion MRI or fMRI allow new insights into the pathophysiologic changes of dementia. The article gives an overview of the current status of structural imaging and an outlook into the potential of functional imaging methods. Detailed results of structural and functional imaging are presented in other articles of this issue.

Age Factors↗