Assessment of implant mobility at second-stage surgery with the Periotest: DICRG Interim Report No. 3. Dental Implant Clinical Research Group.

Many of the presently used methods of evaluating osseointegration at implant uncovering are highly subjective. The Periotest is claimed to offer a more objective means to assess osseointegration by means of microcomputer-controlled percussion. Investigators involved in a long-term clinical study of dental implants being conducted by the Dental Implant Clinical Research Group used the Periotest to evaluate the mobility associated with all study implants at second-stage surgery and correlate the Periotest values with various bone densities. The Periotest values for 1,838 root form implants ranged from -8 to +25. Implants that appeared to be osseointegrated at uncovering recorded a mean Periotest value of -3.37 +/- 3.25, while nonosseointegrated implants had a mean Periotest value of +13.87 +/- 14.27. Mean Periotest values were -3.82 +/- 3.04 for quality 1 bone, -3.70 +/- 3.06 for quality 2 bone, -3.31 +/- 3.18 for quality 3 bone, and -1.29 +/- 3.57 for quality 4 bone. The Periotest has the potential of being a valuable instrument for assessing the status of osseointegration at second-stage surgery.

Alveolar Process

The influence of implant type, material, coating, diameter, and length on periotest values at second-stage surgery: DICRG interim report no. 4. Dental Implant Clinical Research Group.

Many of the presently used methods of evaluating osseointegration at second-stage surgery are highly subjective. The Periotest is claimed to offer a more objective means to assess osseointegration by means of microcomputer-controlled percussion. In 1991 the Dental Implant Clinical Research Group initiated a long-term clinical study in cooperation with the Department of Veterans Affairs to investigate the influence of implant design, application, and site of placement on clinical performance and crestal bone height. As part of this investigation, the Periotest values for 1,565 root form implants were determined at second-stage surgery and correlated with type, material, coating, diameter, and length. Hydroxyapatite-coated implants and increased implant diameter and length produced Periotest values that indicated a greater extent of stability as compared with noncoated implants with shorter diameters and lengths. Hydroxyapatite-coated cylinder-type implants yielded the most favorable Periotest readings. Not only does the Periotest have the potential of being a valuable instrument for assessing implant mobility at second-stage surgery, but it also appears to have the capability of determining slight differences in the implant-bone complex.

Dental Alloys

The effect of smoking on implant survival at second-stage surgery: DICRG Interim Report No. 5. Dental Implant CLinical Research Group.

Smoking has been reported to have a deleterious effect on the oral cavity. Research has associated smoking with oral cancer, periodontal disease, leukoplakia, stomatitis nicotina, and impaired gingival bleeding. In 1991 the Dental Implant Clinical Research Group initiated a prospective, randomized clinical study in cooperation with the Department of Veterans Affairs to investigate the influence of implant design, application, and site of placement on long-term clinical performance and crestal bone height. Over 70 dental and medical history variables and exclusion factors were analyzed to determine relationships, if any, with implant failure at the time of second-stage surgery. The variables were analyzed separately for individual implants, cases (prostheses), and patients. The cases ranged from one to five implants each, and more than one case from a single patient could be included in the investigation. At this interim analysis, 2,066 implants have been placed representing 433 cases in 310 patients. With regard to implant failure rates, possible exclusion variable (9) and medical history variables (39) were not found to be statistically significant. For the dental history variables (23), only the question related to smoking was statistically significant on an implant, case, and patient basis (P < 0.007). Results of this interim analysis suggest that smoking is detrimental to implant success.

Chi-Square Distribution

Patient demographics and implant survival at uncovering: Dental Implant Clinical Research Group Interim Report No. 6.

Implant prognoses for healthy elderly patients have been found to be comparable with those reported for younger patients. In 1991, the Dental Implant Clinical Research Group initiated a prospective, randomized clinical study in cooperation with the Department of Veterans Affairs to investigate the influence of implant design, application, and site of placement on long-term clinical performance and crestal bone height. As a result of the large sample size and wide range of patient ages, the study provided an opportunity to determine if age correlates with implant survival. Interim analysis of 2,132 root form implants at uncovering on an implant, case, and patient basis suggests that implant survival does not appear to be influenced by age in the largely white, male sample.

Adult

Second-stage failures related to bone quality in patients receiving endosseous dental implants: DICRG Interim Report No. 7. Dental Implant Clinical Research Group.

The quality of bone plays an important role in the long-term clinical success of dental implant treatment. An interim evaluation of the relationship between bone quality and the incidence of failure at second-stage surgery is presented. The data include 2,131 root form implants placed by the Dental Implant Clinical Research Group over the past three years. Trends to date suggest differences in the rates of osseointegration among the various bone qualities. Quality 1 bone experienced the greatest failure rate, whereas quality 2 and quality 3 bone had the lowest failure rates.

Alveolar Bone Loss

[A case of hemifacial spasm associated with a cerebellar hematoma].

This is a report of a hemifacial spasm associated with a cerebellar hematoma. A 60 year-old female was admitted to our hospital due to severe vertigo and nausea. On admission, the neurological examination showed drowsy conscious level, cerebellar sign dominant on the left side, and left hemifacial spasm. CT scans disclosed a large hematoma in the left cerebellar hemisphere. An angiography revealed a dominant left PICA, but showed neither vascular malformation nor aneurysm. An emergency removal of the hematoma was carried out by using suboccipital craniectomy. Three days after the surgery, the patient's left hemifacial spasm disappeared completely. She had never suffered from left hemifacial spasm prior to this cerebellar bleeding. The hemifacial spasm was thought to be due to either the compression of the left facial nerve by the PICA which had been displaced by the cerebellar hematoma, or to the fact that the nucleus of the left facial nerve might have been stimulated by the hematoma, and the hemifacial spasm might have been caused as a result of the stimulation. The total removal of the hematoma and the postoperative CSF leakage might have decompressed the facial nerve. It was considered that this might be similar to microvascular decompression.

Cerebellar Diseases

The influence of implant design, application, and site on clinical performance and crestal bone: a multicenter, multidisciplinary clinical study. Dental Implant Clinical Research Group (Planning Committee).

This investigation is designed to provide scientific data that is directly relevant to the placement of dental implants. The study is concerned with the influence of implant design, application, and location on long-term clinical performance and crestal bone response over 5 years of function. It involves approximately 700 patients at 30 Veterans Administration Medical Centers from various geographic regions. Patients are being entered into the study over an 18-month period and monitored (post-loading) over 5 years. The participating centers were randomly assigned to one of two separate, independent study groups. Complications and adverse responses associated with the placement and use of the implants will be evaluated and all failures thoroughly documented. The experimental design and sample size are based on the primary hypothesis that an implant-supported prosthesis will be successful/functional over a 5-year period in at least 90 percent of the cases treated. Secondary hypotheses to be tested are (1) the success rate among implant designs are the same over a 5-year period; (2) the success rate among implant applications are the same over a 5-year period; (3) the success rate of individual implants are the same with regard to jaw location over a 5-year period; (4) the loss of crestal bone at the individual implant sites are the same among the implant designs over a 5-year period; and (5) the complications and adverse responses experienced with the different implant designs are the same over a 5-year period. The experimental design of this multicenter, multidisciplinary, randomized investigation is a cooperative effort of the Department of Veterans Affairs and several United States dental schools.

Alveolar Bone Loss

An evaluation of the Periotest system. Part II: Reliability and repeatability of instruments. Dental Implant Clinical Research Group (Planning Committee).

Investigators involved in a clinical study on dental implants being conducted by the Dental Implant Clinical Research Group participated in a two-part in vitro evaluation of the Periotest system. The first part involved each of 35 investigators taking three readings for each of 16 models designed to simulate an implant in place in the oral cavity and to cover most of the effective measuring range of the instrument. The second part, with which this article is concerned, was conducted by three study investigators to determine the level of agreement in readings for six different Periotest instruments. Readings were taken according to the manufacturer's instructions until two coincident readings were obtained. The readings were compared to evaluate inter- and intrainstrument reliability. Instrument repeatability was evaluated by examining the number of attempts required to obtain the two coincident readings. The Periotest system generally demonstrated a high degree of repeatability and reliability, with higher variability associated with specific model samples.

Dental Implants

Evaluation of the interprobe electronic periodontal probe.

The Interprobe is designed to provide measurements of pocket depths and attachment loss. Investigators involved in a clinical study on dental implants being conducted by the Dental Implant Clinical Research Group participated in an in vitro evaluation of the variability of repeated measurements made with the Interprobe. Measurements were made on holes drilled to predetermined depths in metal blocks. Three readings by investigators for each of nine test holes were in agreement 75.2 percent of the time. At least two of three readings were in agreement in 98.1 percent of the attempts. Either two of three or three of three readings were within 0.5 mm of the actual depth of the holes over 99 percent of the time. No correlation was noted for accuracy of measurements with hole depth or present clinical duties of the investigators. Although slight initial improvement in measurement accuracy was observed, it was not statistically significant in time over the three measurement sequence.

Analysis of Variance

Evaluation of hemodialysis efficiency by an edema fluid model.

The concentrations of urea, creatinine, and uric acid were measured in edema fluid and plasma during hemodialysis and 18 h after hemodialysis. The concentrations of these solutes in plasma were 15-17% lower than in the edema fluid after hemodialysis. Eighteen hours after hemodialysis, however, the concentrations in plasma were almost the same as those in edema fluid. These data suggest that the removal of these solutes from the extracellular space is delayed during hemodialysis. The plasma concentrations obtained at 18 h after hemodialysis are better indicators of hemodialysis efficiency.

Adult

An evaluation of the Periotest system. Part I: Examiner reliability and repeatability of readings. Dental Implant Clinical Group (Planning Committee).

The clinical success of endosseous dental implants is related to the extent of osseointegration. Many of the presently used methods of evaluating osseointegration are highly subjective. The Periotest is claimed to offer a more objective means to assess osseointegration and supporting bone stability of implants by means of microcomputer-controlled percussion. Investigators involved in a clinical study on dental implants being conducted by the Dental Implant Clinical Research Group participated in a two-part in vitro evaluation of the Periotest system. The first part, with which this article is concerned, involved each of 35 investigators taking three readings for each of 16 models designed to simulate an implant in place in the oral cavity and to cover most of the effective measuring range of the instrument. The Periotest system generally demonstrated a high degree of reliability and repeatability, with higher variability associated with specific model samples. Further evaluation of the Periotest as a research instrument will be conducted within the clinical environment of the Dental Implant Clinical Research Group study.

Dental Implants

Endocarditis caused by Candida parapsilosis.

The authors report a case of endocarditis caused by Candida parapsilosis. To the best of our knowledge, a case has not been described previously in Japan in the English literature. A battery of 8 peroxidase-labeled lectins was tested on sections of paraffin-embedded tissue to determine which lectin could be used in the microscopic diagnosis of C. parapsilosis. One lectin, from Archis hypoaea (PNA) was found to react with C. parapsilosis. On the other hand, C. albicans, Aspergillus, Mucor, and Cryptococcus did not react with A. hypoaea (PNA). On fluorescence microscopic study, C. parapsilosis was not fluorescent, but other fungi were fluorescent when exposed to ultraviolet illumination. Therefore, we propose new procedures for identification of C. parapsilosis in tissue sections using lectin histochemistry and fluorescence microscopy.

Candidiasis

Mesangial cell growth in genetically hypertensive rats and effect of calcium antagonists upon this growth.

Mesangial cells play an important role in physiological and pathophysiological regulation of glomerular functions. To explore the involvement of deranged mesangial cell functions in the pathogenesis of hypertension, the growth activity of mesangial cells was compared in stroke-prone spontaneously hypertensive rats (SHRSP) and Wistar-Kyoto rats (WKY). Upon exposure to fetal calf serum, the growth rate was significantly higher in mesangial cells cultured from glomeruli of 4-week old SHRSP than in those of age-matched WKY. This abnormally high growth of SHRSP mesangial cells was significantly inhibited by dihydropyridine calcium antagonists. Of the three antagonists tested, manidipine was the most potent inhibitor. Significant growth inhibition occurred at a concentration as low as 10(-12) M; inhibition as high as 65% was found at 10(-6) M. Calcium antagonists, particularly manidipine, may prevent or delay the development of hypertension not only through vasodilation but also through inhibition of mesangial cell growth. By slowing mesangial cell proliferation, calcium antagonists also may slow the progression of hypertension-induced glomerular sclerosis.

Animals

[A new analytical method for simultaneous measurement of iothalamate and iohexol].

Glomerular filtration rate (GFR) is believed to be the overall index of renal function, and the renal clearance of inulin (Cin) obtained during constant intravenous infusion has long been accepted as the gold standard of GFR measurement. Because of a number of technical difficulties inherent in the assay of inulin concentration in urine and plasma, its utility in clinical practice is limited. Iothalamate, urographic contrast medium, which behaves and is excreted in a fashion similar to inulin, has been accepted as a good filtration marker. We examined whether GFR could be estimated by ionic contrast media, "iothalamate" and non-ionic contrast media, "iohexol", when the high-performance liquid chromatography (HPLC) system was used as the analytic method. In our HPLC system, iothalamate and iohexol could be simultaneously determined. The assay results gave linearity within the wide range of concentrations tested. In seventeen subjects, the renal clearances of creatinine, iothalamate, and iohexol (Ccr, Ciot, and Cioh) were compared with that of inulin. The slopes with zero intercept of Ccr vs Cin, Ciot vs Cin, and Cioh vs Cin were 1.24 +/- 0.02, 1.06 +/- 0.02, and 0.83 +/- 0.02, respectively. In conclusion, an excellent correlation of renal clearance of iothalamate with that of inulin was obtained in patients with a wide range of renal function and normal volunteers. This justifies the use of the single injection of iothalamate and HPLC system as the analytic method in the measurement of GFR.

Chromatography, High Pressure Liquid

Enzyme-linked immunosorbent assay for rapid detection of toxins from Clostridium perfringens.

An enzyme-linked immunosorbent assay (ELISA) with antibodies specific to beta, epsilon and iota ib toxins of Clostridium perfringens was developed to detect beta, epsilon and iota ib toxins, respectively. The ELISA was sensitive enough to detect as little as 1.0 ng/ml of purified beta and iota ib toxins and 0.1 ng/ml of purified epsilon toxin. By means of the ELISA method, 192 isolates of C. perfringens from food samples in Japan and Thailand, and 58 isolates from patients suffering from gas gangrene or gastroenteritis were examined. One isolate from food samples in Japan, three from food samples in Thailand and five from stools of patients with gastroenteritis were C. perfringens type D. One type B and one type C were detected from the stools of patients with gastroenteritis.

ADP Ribose Transferases