PubMed HealthSearch

Biomedical subjects

S Okawa

Publications and source records attributed to S Okawa.

18 recordsLinked to original sources

Involvement of calmodulin- and protein kinase C-related mechanism in an induction process of peroxisomal fatty acid oxidation-related enzymes by hypolipidemic peroxisome proliferators.

Trifluoperazine, a calmodulin antagonist, suppressed the clofibric acid-evoked induction of the peroxisomal cyanide-insensitive fatty acyl-CoA oxidizing system and carnitine acetyltransferase in rat liver and also in cultured rat hepatocytes. H-7, a potent inhibitor of protein kinase C, also suppressed the induction of these enzymes by clofibric acid, bezafibrate, Wyl4,643 or mono(2-ethylhexyl)phthalate in cultured rat hepatocytes. This suppressive effect was also confirmed by the protein composition of hepatocytes treated with clofibric acid and these antagonists, where the increase in the amount of peroxisomal bifunctional enzyme by peroxisome proliferator was markedly suppressed by above two antagonists. Profile of the time-dependent changes in the activities of the two enzymes after clofibric acid treatment showed that there might be two phases in the induction process. The initial phase (0-3 days after the treatment) showed a relative low inducing rate and subsequent phase (3-5 days after the treatment) showed an abrupt induction. The suppressive effect of the above two antagonists was significant in the later phase. In a time course study of the induction process of peroxisomal catalase, bifunctional enzyme or 69 kDa integral membrane protein using immunochemical detection, the induction of the membrane protein by clofibric acid was delayed compared with that of the bifunctional enzyme, where the induction was inhibited almost completely by nicardipine. These experimental results suggest that calmodulin- and protein kinase C-dependent processes play an important role in the process of marked induction of peroxisomal enzymes and membrane protein by drugs in rat liver.

1-(5-Isoquinolinesulfonyl)-2-Methylpiperazine

[Effect of antiplatelet and anticoagulant therapy on secondary prevention and long-term prognosis after acute myocardial infarction in aged patients].

The long-term efficacy and side effects of antiplatelet and anticoagulant therapy for secondary prevention after the first acute myocardial infarction (AMI) were retrospectively assessed in 133 patients over 60 years of age during a mean follow-up period of 36.6 months. Seventy five patients received antiplatelet and anticoagulant therapy (group 1) and 58 patients did not (group 2). In group 1 patients, 54, 12 and 9 patients received ticlopidine, aspirin and warfarin, respectively. Mean age, sex ratio, site of AMI, max CPK value and left ventricular ejection fraction in the convalescent phase did not differ between the two groups. There were no differences between the two groups in terms of the number and kind of combination drugs such as nitrate, beta-blocker and Ca antagonist. During the follow-up period 40 patients died; 18 patients (45%) suffered cardiac death and 22 patients (55%) experienced non-cardiac death. Nineteen patients had recurrent MI and 37 patients had cardiac events which were defined in total as cardiac death, recurrent MI and unstable angina pectoris. The total mortality rate and rate of recurrent MI based on the life time table method were significantly lower in group 1 than in group 2 by the generalized Wilcoxon test. The cumulative total mortality rate in the fifth year was 24.2% in group 1 and 49% in group 2. The cumulative rate for recurrent MI in the fifth year was 7.4% in group 1 and 27.5% in group 2 (p less than 0.05). However, the rate of cardiac events did not differ between the two groups.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged

Successful aggressive treatment against multiple intra-abdominal metastases from renal cell carcinoma 18 years after nephrectomy.

The management of late metastases from renal cell carcinoma is often difficult because of multiple organ involvement. We report a case of multiple metastases from renal cell carcinoma in the duodenum, pancreas, intestine, falciform ligament and liver, 18 years after nephrectomy. The patient underwent a total pancreatectomy following a gastroduodenal arterial embolization to control duodenal bleeding, a resection of the ileum and falciform ligament at a second laparotomy and repeated hepatic arterial embolizations to control the growth of liver metastases. Aggressive treatment should be undertaken in cases of late recurrence of renal cell carcinoma after nephrectomy because of the possibly slow-growing biological character of the tumor.

Abdominal Neoplasms

Co-suppression by nicardipine, a calcium antagonist, of induction of microsomal lauric acid hydroxylation with peroxisome proliferation in clofibrate-treated rat liver.

The in vivo effect of nicardipine, a well-known calcium antagonist, on microsomal omega-oxidation of laurate in clofibrate-treated rat liver was studied. The 15.3-fold induction of the activity by 2 weeks administration of 0.25% clofibrate in the diet was markedly suppressed to about 6-fold by co-administration of nicardipine at 100 mg/kg body weight. Similarly, the induction of peroxisomal beta-oxidation and carnitine acetyltransferase activities were also suppressed by this simultaneous administration by more than 50%. Although clofibrate also induced the activity of reduced nicotineamide adenine dinucleotide phosphate (NADPH)-cytochrome c reductase and increased the hepatic content of cytochrome P-450, no suppressive effect of nicardipine was observed. Contrarily, nicardipine induced the reductase activity and increased the hepatic content of cytochromes P-450 and b5. These results provide the first demonstration of a calcium antagonist, e.g. nicardipine acting as inhibitor of the induction of microsomal omega-oxidation, in association with the inhibition of peroxisome proliferation in animals. The suppression of drug-induced peroxisome proliferation and microsomal omega-oxidation by the calcium antagonist may help in elucidating the causal relationship of the induction mechanisms between peroxisomal and microsomal enzymes.

Animals

Molten titanium flow in a mesh cavity by the flow visualization technique.

The tracer element molten (TEM) method, which provides titanium flow visualization in a mold cavity, was applied to investigate the flow in a mesh pattern. When a pressure casting machine was used, most of the mesh rods were composed of many solidification layers, which implied that the flow was laminar and almost steady. When a centrifugal casting machine was used, the flow was almost irregular and a stack of solidification layers was observed in only a few segments. These results indicate that the flow was turbulent. In a complicated cavity, such as a mesh pattern, pressure rather than centrifugal force acts as an effective casting force. Therefore, in such a cavity, favorable castability can be achieved with high pressure and laminar flow.

Dental Casting Technique

Cardiac sequelae of Kawasaki disease in Japan: statistical analysis.

The proportions of Kawasaki disease patients with cardiac sequelae in Japan were analyzed using nationwide survey data from the 6 1/2-year period July 1982 through December 1988. Of 46,864 cases of Kawasaki disease reported in the surveys, 7637 or 16.3% had cardiac sequelae such as dilation or stenosis of coronary arteries, myocardial infarction, and valvar lesions 1 month or more after onset. The prevalence of cardiac sequelae was particularly high in males, infants younger than 1 year, and children older than 5 years of age. In sequential observation, there was no correlation between the prevalence of cardiac sequelae and periods of high or low incidence of the disease. The prevalence of cardiac sequelae overall declined steadily over the observation period, perhaps as a consequence of increasing use of intravenous gamma globulin. However, children older than the age of 5 years manifested increasing prevalence of cardiac sequelae over the observation period, probably as a result of lower rates of intravenous gamma globulin administration.

Child

[Grinding of titanium. 1. Commercial and experimental wheels made of silicon carbide abrasives].

Cast titanium was ground with commercial and experimental wheels made of silicon carbide abrasives, and their grinding performance was investigated. With the vitrified wheels made of the GC abrasive, at a higher the wheel circumferential speed and heavier the grinding pressure, the cutting rate was greater, accompanied by violent wear of the wheel. Being independent of the wheel speed, the grinding ratio reached about 1 under pressure heavier than 100 gf. The MgO-MgCl2-bonded wheels of the C abrasive exhibited a similar tendency. The manner in which the wheel was moved over the work during grinding proved to be very important, compared with the Ni-Cr alloy as reported previously. Only depression of the wheel against the work resulted in chemical attrition of the abrasive and discoloration of the work surface, or grinding burn, due to oxidation of titanium. Even when the wheel was moved over the work, chip-formation process of the cutting edge was far from ideal, and the work surface was contaminated due to reaction of titanium with the abrasive. At a higher wheel circumferential speed, more chips were loaded or built-up in the wheel and strongly rubbed the work surface, resulting in violent wear of the wheel; loading and dislodging of such chips were repeated.

Carbon

[Grinding of titanium. 2. Commercial vitrified wheels made of alumina abrasives].

Cast titanium was ground with commercial vitrified wheels made of alumina abrasives, and their grinding performance was investigated. For cutting, the appropriate circumferential speed of the alumina wheels was about 700 m/min. A speed lower or higher than this yielded unfavorable grinding results, which were attributed to wheel loading or chemical attrition of the abrasive, respectively. The hard wheel made of the A abrasive was suitable for grinding of titanium, and moreover, the wheel of the WA abrasive was more suitable than that made of the A abrasive. Generally, the cutting rate of the alumina wheels was inferior to that of the silicon carbide ones investigated previously. Depression of the wheel against the work yielded unfavorable grinding results; the manner in which the wheel was moved over the work during grinding was very important, compared with the silicon carbide wheels. Although the wheel was moved over the work, the high circumferential speed of the wheel resulted in chemical attrition of the abrasive and discoloration of the work surface, or grinding burn. The grinding burn layer mainly consisted of a few microns-thick titanium oxide.

Aluminum Oxide

[Determination of titanium flow by the tracer element molten method in the dental precision casting. 1. The principle of flow visualization and application to simple castings].

The tracer element molten (TEM) method has been developed for flow visualization of molten Titanium in dental precision casting. The principle of this technique is as follows. When Titanium is cast, the tracer element wire inserted previously into the selective point of the sprue is molten little by little and distributed according to the molten Titanium flow in the mold cavity. After solidification, to observe the flow pattern, the tracer element needs to be analyzed on a section of the casting by EPMA equipped with the stage scan mapping system. This technique using Ag, Au, Pd or Pt as a tracer has been applied to some simple castings in shape and has been confirmed to be a very powerful technique for Titanium flow visualization in dental castings.

Dental Casting Technique

[Reactions at the nonprecious metal-ceramic interface during porcelain firing. (3) A commercial alloy forming much Cr oxide during firing].

To examine the interface reaction between porcelain and a commercial Ni-Cr dental alloy (containing higher Cr and Mo) during porcelain firing, electron probe microanalyzer (EPMA) and X-ray diffraction have been used to characterize the interface which has emerged by means of selective dissolution of the alloy caused by a bromine-methanol solution. Much Cr oxide was formed at the early stage of firing, and remained in the reaction layer even if the holding time at 960 degrees C was up to 8 minutes. As a result, many Cr atoms diffused into the porcelain layer, most of which was found to form oxides through X-ray diffraction. Moreover, the porcelain layer nearest to the oxide layer was deduced to be modified seriously.

Chromium

Use of rabbit antiboty IgG bound onto plain and aminoalkylsilyl glass surface for the enzyme-linked sandwich immunoassay.

Rabbit antibody IgG was bound onto aminoalkylsilyl or plain glass rods by simple adsorption. For comparison, rabbit antibody IgG was also bound onto glutaraldehyde-activated aminoalkylsilyl glass rods. These antibody-glass rods were tested by the sandwich procedure using Fab' fragments of rabbit antibody conjugated with beta-D-galactosidase from Escherichia coli. The glutaraldehyde-activated aminoalkylsilyl glass showed the largest capacity to bind antigen and the plain glass showed the smallest. However, the antibody-glass rods prepared by simple adsorption were as useful for the sandwich immunoassay of macromolecular antigens as those prepared with glutaraldehyde. With all the antibody-glass rods prepared, 0.1 to 10 fmol of ornithine delta-aminotransferase from rat liver and 2,4-dinitrophenyl human IgG were measurable. More than 10 fmol of the antigens may be measurable with larger amounts of the antibody-beta-D-galactosidase complexes, although the non-specific binding of the complexes to the solid phase increases to limit the sensitivity of the immunoassay.

Animals

Enzyme-linked sandwich immunoassay of macromolecular antigens using the rabbit antibody-coupled glass rod as a solid phase.

A highly sensitive sandwich immunoassay of macromolecular antigens using the rabbit antibody Fab' - beta-D-galactosidase complex and the rabbit antibody immunoglobulin-G-coupled glass rod as a solid phase is described. The Fab' fragments of rabbit antibody IgG are conjugated with beta-D-galactosidase from Escherichia coli using N,N'-o-phenylenedimaleimide. Rabbit antibody IgG is coupled to the aminoalkylsilyl glass rods (3 mm in diameter and 5 mm in length) using glutaraldehyde. A wide range of the concentrations of rabbit IgG fraction (20-2000 mug/ml) is effective for coupling, and the amount of rabbit immunoglobulin G coupled can be controlled. The smallest amounts of ornithine delta-aminotransferase from rat liver, human immunoglobulin G and 2,4-dinitrophenyl human immunoglobulin G that can be determined are 0.03, 0.3 and 0.04 fmol, respectively. The sensitivity of the assay for these antigens is affected mainly by the non-specific binding of the complexes to the solid phase and the ability of antigen molecules, adsorbed on the solid phase, to bind specifically the complexes. The assay with the rabbit antibody immunoglobulin-G-coupled glass rods is simpler and more sensitive than that with the rabbit antibody immunoglobulin-G-coupled Sepharose 4B.

Adsorption

[Slip casting of stainless steel powder (author's transl)].

Slip casting of stainless steel powder (AISI type 316 L) was investigated as means of forming medical and dental porous restorations. This research was undertaken to evaluate the effects of the particle size and aging of casting slip and firing conditions. Bulk density was used as a measure of the degree of sintering. Water contents of casting bodies decreased with the particle size and its casting rates, bulk densities and bending strengths increased. Aging of slip decreased casting rates, water contents and bending strengths of the casts. The bulk densities of the sintered stainless steel increased with sintering time and temperature. The porosities of the materials decreased with the particle size and the elevating temperature. The bending strengths of the materials increased sharply with the decreasing particle size. The optical micrographs did not always show the uniform elimination of pores in the sintered. Aging of slip increased a little the bulk densities of the materials and decreased the porosity and the bending strength.

Dental Casting Technique