Effect of different location of atrial lead position on nearfield and farfield electrograms in dual chamber pacemaker-defibrillators.

The normal functioning of dual chamber pacemaker-cardioverter defibrillator (AV pacer/ICD) may be affected by oversensing of the farfield R wave (FFRW) by the atrial channel. This study aimed to investigate whether placement of the AV pacer/ICD's atrial lead at a lateral (LAT) wall location compared to a medial (MED) location i.e. the appendage of the right atrium, would reduce the amplitude of FFRWs but not the nearfield atrial electrograms (AEGMs) during sinus rhythm (SR) and ventricular fibrillation (VF). In 17 patients, real time electrograms were recorded during SR and induced VF through the atrial lead initially at the MED and subsequently at the LAT location. In 10 patients the electrograms in SR were also recorded on a computerized data acquisition and recording system at different band-pass filter settings. Although FFRWs were recorded both at MED and LAT locations, they were much smaller, 3.5+/-4.1mm during SR and 1.7+/-2.2mm during VF at the LAT location. At 30-500Hz band-pass filter, lower amplitudes of FFRWs 0.14+/-0.09 mV were recorded at the LAT location. The V/A ratios of the amplitudes of FFRWs and AEGMs were smaller at the LAT location during SR and VF. The nearfield AEGMs were of similar amplitudes at the MED and LAT locations. These data indicate that lower amplitudes of FFRWs are recorded by placement of the atrial lead at the lateral wall of the right atrium. Oversensing of FFRWs may be prevented to improve functioning of the AV pacer-ICD.

Aged↗

Feasibility, safety, and determinants of extraction time of percutaneous extraction of endocardial implantable cardioverter defibrillator leads by intravascular countertraction method.

Previous studies of the removal of implantable cardioverter defibrillator (ICD) leads have been restricted to case reports or small series. In this report, we describe our experience in ICD lead extraction by intravascular countertraction method using Cook's extraction kit. A total of 47 high-voltage (HV) leads, 3 rate sensing (S) leads, and 2 subcutaneous arrays were removed from 42 patients (33 men, 9 women; mean age 59 years [range 14 to 81]). One HV superior vena cava (SVC) lead and 11 HV right ventricular (RV) leads were explanted by manual traction only and defined in the "lead removal" category. One S lead was removed using a femoral venous approach. The remaining 37 leads were explanted by SVC approach using extraction sheaths and defined in the "lead extraction" category. Twenty leads were extracted for "infectious" (group A) and 17 leads for "noninfectious" (group B) etiologies for which extraction times of 27.0+/-18.0 and 27.0+/-15.0 minutes (mean+/-SD), respectively, were not different. Although extraction time, 34.0+/-11.0 minutes, for leads implanted for >48 months was longer than 23.0+/-16.0, 28.0+/-18.0, and 24.0+/-14.0 minutes, for leads with implant durations of 12, 24, and 48 months, respectively, such differences were not statistically significant. The extraction time, however, was directly related to the degree of fibrosis around the lead, 39.0+/-15.0 minutes for leads with severe fibrosis compared with 13.0+/-6.0 minutes for the leads with mild fibrosis (p<0.001). Patient's age, sex, or history of coronary artery bypass graft surgery did not significantly affect extraction time. All except the initial 2 lead extractions were performed in the electrophysiology laboratory. No mortality or serious complications associated with the procedure using these methods were observed.

Defibrillators, Implantable↗

Prevalence and characteristics of escape rhythms after radiofrequency ablation of the atrioventricular junction: results from the registry for AV junction ablation and pacing in atrial fibrillation. Ablate and Pace Trial Investigators.

BACKGROUND: Radiofrequency ablation of the atrioventricular junction is a well-established procedure for the management of atrial fibrillation refractory to medical therapy. However, there are few data available on the prevalence and characteristics of the escape rhythms that are present after the procedure. METHODS: The Ablate and Pace Trial was a prospective, multicenter registry of atrioventricular junction ablation and pacing in atrial fibrillation. Ablation of the atrioventricular junction was accomplished with radiofrequency energy with standard techniques. Before discharge from the hospital, patients underwent a systematic analysis of the rate and morphologic features of the escape rhythm, if any, that was present when the pacing rate was gradually decreased. RESULTS: There were 156 patients from 16 centers who underwent attempted radiofrequency ablation of the atrioventricular junction. The procedure was successful in 155 (99%) of 156 patients. An escape rhythm was present in 104 patients (67%) after radiofrequency ablation. The escape rate ranged from 11 to 65 beats/min (mean 39 +/- 10 beats/min). Only 49 patients (31%) had an escape rate >/=40 beats/min. Of the 104 patients with an escape rhythm, 53 patients (51%) had a QRS that was unchanged from baseline. There was no correlation between the number of radiofrequency applications and the presence of an escape rhythm. CONCLUSION: The majority of patients who undergo radiofrequency catheter ablation of the atrioventricular junction are pacemaker dependent after the procedure, as defined by lack of an escape rhythm or the presence of an escape rhythm that is <40 beats/min.

Adult↗

Efficacy and safety of catheter ablation in octogenarians.

OBJECTIVES: To determine whether catheter ablation is safe and effective in patients over the age of 80. BACKGROUND: There is a tendency to withhold invasive therapy in the elderly until it has been proven safe and effective. METHODS: Over a two-year period from February 1, 1996 to February 1, 1998, 695 consecutive patients underwent 744 catheter ablation procedures of supraventricular and ventricular arrhythmias. These patients were divided into three groups based on age: > or =80 years, 60 to 79 years and <60 years. Acute ablation success, using standard criteria and complication rates for these three groups were determined. RESULTS: There were 37 patients > or =80 years, 275 patients 60 to 79 years and 383 patients <60 years old. The overall acute ablation success rate for the entire group was 95% with no difference in rates among the three groups (97%, > or =80 years; 94%, 60-79 years; 95%, <60 years). The percentage of patients undergoing His bundle ablation was greatest in the > or =80-year-old group (43% vs. 19% vs. 2%, p < 0.01), and the percentage of patients undergoing accessory pathway ablation was greatest in the <60-year-old patients (0% vs. 4% vs. 25%, p < 0.01). The overall complication rate for the entire group was 2.6%, and there was only one major/life-threatening complication. There was no difference in complication rates among the groups (0%, > or =80 years; 2.2%, 60 to 79 years; 3.1%, <60 years). Based on the sample size, the 95% confidence interval is 0% to 7.8% for an adverse event in the octogenarian. CONCLUSIONS: Catheter ablative therapy for the arrhythmias attempted in the very elderly appears to be effective with low risk. Ablation results appear to be comparable with those noted in younger patients.

Aged↗

Early detection of acute allograft rejection by linear and nonlinear analysis of heart rate variability.

OBJECTIVE: The first months after orthotopic heart transplantation are associated with the highest risk of acute allograft rejection. This study explores the utility and reliability of linear and novel nonlinear metrics of heart rate variability as predictors of graft rejection. The underlying hypothesis is that the transplanted heart, in response to inflammatory mediators, alters the dynamic properties of its rhythm-generating system. METHODS: In a cross-sectional study of 45 patients who had undergone heart transplantation, spanning a period of 4 months after the operation, heart rate variability was examined by time- and frequency-domain analysis. The nonlinear features of heart rate variability were studied by computing a pointwise correlation dimension of R-R interval time series. The results of heart rate variability analysis were compared with those of endomyocardial surveillance biopsy studies using the International Society for Heart and Lung Transplantation scoring system. RESULTS: Duration of heart transplantation itself exhibited a significant (P<.05) association with the onset of rejection. Specific predictors of acute rejection based on heart rate variability were identified, including shortening of the R-R interval (from 700 +/- 68 to 648 +/- 72 ms), an increase in the ratio of low-frequency (0.04-0.15 Hz) to high-frequency (0.15-0.40 Hz) spectral power (from 0.3 +/- 0.2 to 0.6 +/- 0.4), and a decrease in pointwise correlation dimension values (from 1.7 +/- 0.7 to 0.9 +/- 0.3 units). Multivariable logistic regression analysis (R (2) = 0.4) revealed that the only significant independent risk predictors were pointwise correlation dimension (odds ratio, 2.2 per 0.1 unit) and duration of heart transplantation (odds ratio, 1.7 per week). CONCLUSION: Nonlinear measures of heart rate variability provide noninvasive means for identifying patients undergoing cardiac transplantation with acute rejection, thereby enabling the assessment of the time-dependent adaptive response of the donor heart to its host.

Adult↗

Escape capture bigeminy: a manifestation of sinoatrial conduction block.

Sinoatrial block (SAB) is often difficult to identify in the presence of bradycardic rhythms. This study demonstrates several manifestations of so-called escape capture bigeminy in 14 patients. Although periods of 1:1 sinoatrial conduction can aid in the analysis of SAB, the electrocardiographic pattern of bigeminal rhythm may be the only electrocardiographic clue of SAB. In one case, both sinoatrial entrance and exit block were identified. In eight instances, digitalis or digitalis plus a beta or calcium blocking agent could be partially implicated as the cause of SAB. In 6 of 14 patients, a permanent pacemaker was required to correct the bradycardia, in spite of discontinuation of aggravating antiarrhythmic agents or electrolyte derangement.

Electrocardiography↗

Radiofrequency catheter ablation of atrioventricular nodal reentrant tachycardia after orthotopic heart transplantation.

Patients with orthotopic heart transplantation may develop a variety of arrhythmias. Successful radiofrequency catheter ablation for tachyarrhythmias from manifest and concealed accessory bypass tracts in transplant patients has been previously reported. We present a patient with orthotopic heart transplantation who developed typical atrioventricular nodal tachycardia, which was successfully treated by radiofrequency catheter ablation.

Aged↗

Extraction of pacemaker and implantable cardioverter defibrillator leads.

The common reasons for removal of pacing and defibrillator leads are infection, malfunction, or design defects such as fracture of J wires in Teletronics Accufix leads (Telectronics Pacing, Englewood, CO), which impose considerable risk for cardiac morbidity and mortality. Chronically implanted leads are fixed to the myocardium by fibrous tissue. Fibrous scar tissue may also encase the lead along its course. Furthermore, fragility of the lead and its tendency to break when extraction force is applied to overcome resistance imparted by the scar tissue add to the challenge of lead extraction. Thus, the extraction of chronically implanted leads is an important issue. Until a few years ago, the only methods available for the removal of chronically implanted leads were traction on the proximal segment of the lead and cardiac surgery. New techniques were developed to extract the leads by a transvenous approach using locking stylets, sheaths, snares, and retrieval baskets. Lead extraction using intravascular countertraction methods has since evolved as a specialty of its own. Progress has also been made in developing other system, such as Excimer laser energy for lead extraction. In this article, we discuss principles, techniques, and experience with these methods of extraction of chronic pacemaker and defibrillator leads.

Cardiac Surgical Procedures↗

Intravascular extraction of problematic or infected permanent pacemaker leads: 1994-1996. U.S. Extraction Database, MED Institute.

Of the 400,000-500,000 permanent pacemaker leads implanted worldwide each year, around 10% may eventually fail or become infected, becoming potential candidates for removal. Intravascular techniques for removing problematic or infected leads evolved over a 5-year period (1989-1993). This article analyzes results from January 1994 through April 1996, a period during which techniques were fairly stable. Extraction of 3,540 leads from 2,338 patients was attempted at 226 centers. Indications were: infection (27%), nonfunctional or incompatible leads (25%), Accufix or Encore leads (46%), or other causes (2%). Patients were 64+/-17 years of age (range 5-96); 59% were men, 41% women. Leads were implanted 47+/-41 months (maximum 26 years), in the atrium (53%), ventricle (46%), or SVC (1%). Extraction was attempted via the implant vein using locking stylets and dilator sheaths, and/or transfemorally using snares, retrieval baskets, and sheaths. Complete removal was achieved for 93% of leads, partial for 5%, and 2% were not removed. Risk of incomplete or failed extraction increased with implant duration (P<0.0001), less experienced physicians (P<0.0001), ventricular leads (P<0.005), noninfected patients (P<0.0005), and younger patients (P<0.0001). Major complications were reported for 1.4% of patients (<1% at centers with >300 cases), minor for 1.7%. Risk of complications increased with number of leads removed (P<0.005) and with less experienced physicians (P<0.005); risk of major complications was higher for women (P<0.01). Given physician experience, appropriate precautions, and appropriate patient selection, contemporary lead removal techniques allow success with low complication rates.

Adolescent↗

Adenosine in the mammalian heart: nothing to get excited about.

Until quite recently, the cardiodepressant actions of adenosine were widely accepted. A nucleoside that produces negative chronotropic and ionotropic effects, adenosine, has been used clinically as the drug of choice for terminating supraventricular (atrioventricular node) tachycardia and is likely to play an important part in regulating arrhythmogenic activity as an endogenous antiarrhythmic metabolite. Despite this, recent experimental data, particularly resulting from in vitro studies using animal models, have shown a paradoxical excitable action of adenosine in the heart. In this article, Amir Pelleg and Steven Kutalek present the reasons why they continue to believe that any excitatory actions of adenosine in the heart are clinically irrelevant.

Adenosine↗

Extraction and replacement of permanent pacemaker leads through occluded vessels: use of extraction sheaths as conduits--balloon venoplasty as an adjunct.

Patients (pts) may present for lead extraction with symptomatic or asymptomatic subclavian vein or superior vena cava thrombosis. Replacement of permanent pacemaker leads (PPLs) in these pts may be difficult and may require accessing a new site. We examined the utility of replacing PPLs through completely occluded vessels using extraction sheaths as conduits through the total occlusion. Over six years, a total of 210 atrial and/or ventricular PPLs were extracted from 137 pts. Two pts presented with angiographically documented thrombotic occlusion of the subclavian vein. One additional pt. who had presented with a superior vena cava (SVC) syndrome, had a totally occluded innominate vein and SVC occlusion. Balloon venoplasty was used as an adjunct to dilate the SVC. In all pts, after PPLs were removed via a subclavian extraction sheath through the occluded vessel, the retained sheath was used to place a guide wire, then a peel away dilating sheath, to insert new PPLs, in each case on the side of total venous occlusion. Seven PPLs and two lead fragments were extracted, and five new PPLs replaced, ipsilateral to the venous occlusion. These data show that extraction of PPLs through thrombosed veins may be performed successfully and may not require replacing the leads through a new site. This technique spares the pt the need to access the opposite subclavian vein, and it avoids an excessive number of PPLs in the subclavian vein and SVC. The procedure illustrates an efficient means to reintroduce new PPLs with the potential to reduce associated morbidity, since repeat puncture of the subclavian vein is not required. Safety of the procedure as a whole must be considered with regard to the known risks of lead extraction, some complications of which may be substantial using current techniques.

Adult↗

Management of distal electrode detachment during lead extraction.

A telectronics 330-801 atrial active fixation lead with multiple J retention wire fractures was extracted. Separation of the distal electrode occurred due to antecedent inner conductor fracture between the endocardial electrode pair. Techniques for removal of the free distal electrode are described, including use of biopsy forceps and a snare.

Aged↗

The effects of programmed ventricular stimulation on plasma procainamide levels: an experimental model.

To evaluate the effects of programmed ventricular stimulation on resultant plasma concentrations of intravenously administered procainamide, drug dosing was performed with and without ventricular stimulation on two separate days (48 hours apart) in 12 dogs (13 dosing trials) at > or = 14 days after myocardial infarction (mean: 62 days). During infarct surgery, three bipolar electrodes were plunged into left ventricular epicardium, externalized, and later used for ventricular stimulation. On the first study day, procainamide was dosed to achieve two sequential plateau plasma levels (I and II), with a 20-minute equilibrium period at each plateau before ventricular stimulation. Plasma procainamide concentrations were measured before initiation of ventricular stimulation and at the completion of ventricular stimulation for each sequential plateau level. Stimulation involved delivery of one, two, and three extrastimuli at three paced cycle lengths at three left ventricular sites before procainamide dosing and at each of the two procainamide plateau levels. Three dogs were excluded from analysis due to induction of lethal ventricular arrhythmias. No ventricular arrhythmias were induced in the remaining nine animals. On the second study day, procainamide was dosed identically, but no ventricular stimulation was performed. Intravenous drug administration and collection of plasma concentration samples were performed with +/- 1 minute on both study days. Mean plasma procainamide concentrations at the end of ventricular stimulation at dosage Levels I & II were 10% and 12% greater (P < 0.02 and P < 0.005, respectively) than plasma concentrations measured at comparable times on the study day when no ventricular stimulation was performed.(ABSTRACT TRUNCATED AT 250 WORDS)

Animals↗

Upper rate lockout: an unexpected feature of rate adaptive atrioventricular delay.

We present a case in which use of rate adaptive AV delay resulted in unexpected pacemaker 2:1 AV block when the patient's atrial rate exceeded the pacemaker maximum tracking rate but was below the predicted multiblock rate. "Lockout" of normal upper rate behavior was accompanied with the requirement of a slower atrial rate for reassociation than loss of atrial tracking, a form of upper rate hysteresis. The mechanism of upper rate lockout is discussed, along with potential ways to avoid the problem. The use of software based pacemakers with an extended range of programmable options allows the most flexibility in optimizing pacemaker performance in an individual patient.

Atrioventricular Node↗

Inappropriate discharge by an implantable cardioverter defibrillator: recognition of myopotential sensing using telemetered intracardiac electrograms.

Inappropriate therapy from implantable anti-tachyarrhythmia devices is a common problem with a variety of etiologies. The verification of arrhythmias or other sensed events that precipitate defibrillating shocks is difficult with first- and second-generation devices due to the absence of sufficient data storage and the inability to examine stored and real-time intracardiac electrograms. In addition, the absence of premonitory symptoms is an unreliable marker for the appropriateness of defibrillator shocks. The incorporation of improved data storage and the ability to inspect intracardiac electrograms in newer devices have greatly increased the ability to diagnose abnormal device behavior as shown in the following case report. Inappropriate implantable cardioverter defibrillator discharge due to myopotential sensing is described. The diagnosis was facilitated by telemetered intracardiac electrograms.

Action Potentials↗

The automated implantable cardiac defibrillator. Prophylaxis in cardiac sarcoidosis.

A patient with cardiac sarcoidosis proved by biopsy specimen and no history of sudden death or clinical sustained ventricular tachycardia prophylactically received an implantable cardioverter defibrillator (ICD) that later reversed an episode of near syncope. The patient was supported with the ICD until heart transplantation. The physiology and treatment of arrhythmias associated with cardiac sarcoidosis is described. Consideration for use of the ICD in asymptomatic patients and as bridge therapy until heart transplantation is discussed.

Cardiomyopathies↗

Visualization of implantable defibrillator patches by two-dimensional echocardiography.

Implantable cardioverter defibrillators are being used with increasing frequency for the management of life-threatening ventricular arrhythmias. In order to determine whether the titanium mesh of the defibrillator patch causes ultrasonographic acoustical interference, 30 patients underwent prospective serial echocardiographic examination. In addition, studies were reviewed to determine whether the defibrillator patches could be visualized with standard two-dimensional echocardiography. In no patient did the anterior patch produce acoustical interference, and, unless specific measures were utilized (such as a standoff pad, a zoom feature, or a 5-MHz transducer), the patches were rarely visualized.

Adult↗