Evaluation of automated RNA-extraction technology and a qualitative HCV assay for sensitivity and detection of HCV RNA in pool-screening systems.

BACKGROUND: The objective of this study was the evaluation of NAT technology for the detection of HCV RNA in plasma pools according to the recommendations of the Paul Ehrlich Institute (5000 IU/mL/donation) and the Committee for Proprietary Medical Products (100 IU/mL/manufacturing pool). STUDY DESIGN AND METHODS: Serial dilutions of both the EUROHEP standard (3,800 genome equivalents [geq]/mL; HCV genotype 1) and the World Health Organization (WHO) international standard (100,000 IU/mL; HCV genotype 1) were made in S/D plasma (ESPEP plasma, OctaPharma), which was nonreactive in serologic tests. Serial dilutions of plasma (2 mL) were used for extraction of HCV RNA with an automated version of a nucleic acid isolation method (NucliSens Extractor, Organon Teknika). HCV RNA was co-extracted from 2 mL of plasma, together with 84 copies of an in vitro-synthesized single-strand RNA serving as internal extraction control (IC) to monitor the efficiency of extraction and PCR. Amplification and detection of both HCV RNA and IC RNA were performed with an automated PCR system and a qualitative HCV assay (COBAS Amplicor 2.0 HCV, Roche Diagnostics). RESULTS: A cutoff value of 16 geq per mL (10/10 runs [100% hit rate]) was found by using the EUROHEP standard, whereas the WHO international standard had a cutoff value of approximately 12 IU per mL (10/10 runs [100% hit rate]). The IC had a cutoff value of approximately 17.5 copies per mL (6/6 runs [100% hit rate]). Forty-two copies per mL of IC RNA were found in 282 of 284 runs (99% hit rate). The negative controls (ESDEP plasma) were negative in all experiments. Experiments with pool sizes of 12, 24, 48, and 96 using serial dilutions of the WHO international standard revealed a cutoff value of 8 IU per mL (100% hit rate). The EUROHEP standard and the WHO international standard were detected with a 50 percent detection endpoint of 5.2 geq per mL and 1.5 IU per mL, respectively. CONCLUSION: This test system (NucliSens Extractor, and the COBAS Amplicor 2.0 HCV assay) revealed a high sensitivity for HCV RNA; considering the proposed requirements for sensitivity of NAT assays for the detection of HCV RNA in donor plasma, pool sizes of about 400 donors are possible. These endpoint results indicated that 1 IU is equal to about 3.4 geq.

Autoanalysis↗

Compodock, a new device for sterile docking.

BACKGROUND: A new device for sterile docking, the Compodock (Fresenius NPBI Transfusion Technology), was developed for connecting PVC tubing for medical use while maintaining sterility. STUDY DESIGN AND METHODS: Sterility of the connections was assessed by welding tubing with a heavy exterior contamination with Bacillus subtilis spores and also by welding in an environment contaminated with aerosols of B. subtilis. Tubing was either dry or liquid-filled ("wet") and had various diameters. Bacterial culture medium was flushed through the welded area and subsequently cultured. Tensile strength was measured, and, under semi-routine conditions, Compodock was tested for user friendliness and speed. RESULTS: None of the cultures of welded tubing with exterior contamination showed growth, neither the dry-dry (n = 434) nor the wet-wet connections (n = 622). Cultures were also negative for welds made in the contaminated environment (dry-dry, 67; wet-wet, 55). Tensile strength complied fully with ISO 3826 standards (that is, a force of 20 newtons [N] for 15 sec), with a mean maximal strength ranging from 73 to 100 N, depending on diameter and content of the tubing. The semi-routine handling was regarded as good: welds were easily opened; there were clear instructions and error warnings; and the processing time averaged 52 seconds. CONCLUSION: The Compodock is able to maintain a functionally closed system, with maintenance of sterility, despite heavy exterior bacterial contamination; tensile strength conformed to ISO standards. Compodock is suitable for routine implementation in the blood bank.

Bacillus subtilis↗