PubMed Health⌕ Search

Biomedical subjects

S Pedersen-Bjergaard

Publications and source records attributed to S Pedersen-Bjergaard.

14 recordsLinked to original sources

Reduction of extraction times in liquid-phase microextraction.

Recently, we introduced a simple and inexpensive disposable device for liquid-phase microextraction (LPME) based on porous polypropylene hollow fibres. In the present paper, extraction times were significantly reduced by an increase in the surface of the hollow fibres. The model compounds methamphetamine and citalopram, were extracted from 2.5 ml of urine, plasma, and whole blood after dilution with water and alkalisation with 125 microl of 2 M NaOH though a porous polypropylene hollow fibre impregnated with hexyl ether and into an aqueous acceptor phase consisting of 0.1 M HCl. Two commercially available hollow fibres, which differed in surface area, wall thickness and internal diameter, were compared. An increase in the contact area of the hollow fibre with the sample solution by a factor of approximately two resulted in reduction in equilibrium times by approximately the same factor. Thus, the model compounds were extracted to equilibrium within 15 min from both urine and plasma, and within 30 min from whole blood. For the first time LPME was utilised to extract drugs from whole blood, and the extracts were comparable with plasma both with regard to sample clean-up and extraction recoveries. Extraction recoveries for methamphetamine and citalopram varied from 60 to 100% using the two fibres and the different matrices.

Chromatography, Liquid↗

Liquid-phase microextraction and capillary electrophoresis of citalopram, an antidepressant drug.

A newly developed disposable device for liquid-phase microextraction (LPME) was evaluated for the capillary electrophoresis (CE) of the antidepressant drug citalopram (CIT) and its main metabolite N-desmethylcitalopram (DCIT) in human plasma. CIT and DCIT were extracted from 1 ml plasma samples through hexyl ether immobilised in the pores of a porous polypropylene hollow fibre and into 25 microl of 20 mM phosphate buffer (pH 2.75) present inside the hollow fibre (acceptor phase). Prior to extraction, the samples were made strongly alkaline in order to promote LPME of the basic drugs. Owing to the high ratio between the volumes of sample and acceptor phase, and owing to high partition coefficients, CIT and DCIT were enriched by a factor of 25 to 30. In addition, sample clean-up occurred during LPME since salts, proteins and the majority of endogenic substances were unable to penetrate the hexyl ether layer. Since the extracts were aqueous, they were injected directly into the CE instrument. Limits of quantification (S/N= 10) for CIT and DCIT in plasma were 16.5 ng/ml and 18 ng/ml respectively, while the limits of detection (S/N=3) were 5 ng/ml and 5.5 ng/ml respectively. This enabled CIT (and DCIT) to be analysed within the therapeutic range by LPME-CE and detection limits were comparable with previously reported HPLC methods.

Antidepressive Agents, Second-Generation↗

Separation of neutral compounds by microemulsion electrokinetic chromatography: fundamental studies on selectivity.

The selectivity of microemulsion electrokinetic chromatography (MEEKC) was studied utilizing some uncharged model compounds like aromatic amides, steroids, and esters of nicotinic acid. The cosurfactant of the microemulsion was found to be the most important factor affecting the selectivity, and alteration between 6.6% of 1-propanol, 1-butanol, tetrahydrofuran, and 2-ethoxyethanol caused several substantial changes in the migration order. In addition, the nature of the surfactant was found to significantly affect the selectivity. In this case, changes in order of migration was observed by replacement of half the content of sodium dodecyl sulfate (SDS) with either sodium dioctyl sulfosuccinate (SDOSS), 3-(N,N-dimethylmyristylammonio) propanesulfonate (MAPS), polyoxyethylene sorbitan monolaurate (Tween 21), and polyoxyethylene 23 lauryl ether (Brij 35). MEEKC was also accomplished with 3.3% of the anionic surfactant sodium cholate and with the cationic surfactant N-cetyl-N,N,N-trimethylammonium bromide (CTMA). Both provided substantial differences in selectivity as compared to the SDS-based systems. With SDS as surfacant, the concentration was varied within 1.0-4.5%. Minor selectivity changes were observed as the concentration of the surfacant was reduced, but the major effect was a reduction in the total migration time. The organic solvent of the microemulsion droplets was found only to have minor impact on the selectivity.

Chromatography↗

Liquid-liquid extraction procedures for sample enrichment in capillary zone electrophoresis.

This review article presents an overview of applications of liquid-liquid extraction (LLE) for analyte enrichment and clean-up of samples prior to capillary zone electrophoresis (CZE). The basic principles of LLE are discussed with special emphasis on analyte enrichment. In addition, attention is focused on the requirements for the final extract to be compatible with CZE. The paper discusses selected examples from the literature with special emphasis on detection limits in drug analysis and in environmental chemistry. Finally, the paper focus on alternative liquid-phase extraction concepts based on electroextraction, supported liquid membranes, and liquid-phase microextraction.

Body Fluids↗

Selectivity in microemulsion electrokinetic chromatography.

Microemulsion electrokinetic chromatography (MEEKC) is a most promising separation technique providing good selectivity and high separation efficiency of anionic, cationic as well as neutral solutes. In MEEKC lipophilic organic solvents dispersed as tiny droplets in an aqueous buffer by the use of surfactants provide a pseudo-stationary phase to which the solutes may have an affinity either to the surface or they may even partition into the droplets. When the droplets are charged, typically negatively, they will migrate opposite to the electroosmotic flow and hence separation of neutral solutes may take place. In the present paper focus has been set on how to change selectivity in MEEKC. Changes in the nature of surfactant as well as in pH have been shown to be powerful tools in changing the selectivity. The type of lipophilic organic phase is of less importance for the separation of fairly lipophilic solutes. Also changes in the temperature surrounding the capillary may alter the selectivity.

Chromatography, Micellar Electrokinetic Capillary↗

Microemulsion electrokinetic chromatography in suppressed electroosmotic flow environment. Separation of fat-soluble vitamins.

Microemulsion electrokinetic chromatography (MEEKC) was carried out in a pH 2.5 phosphate buffer to effectively suppress the electroosmotic flow (EOF). With 66.6% (w/w) 25 mM phosphate buffer pH 2.5, 20.0% (w/w) 2-propanol, 6.6% (w/w) 1-butanol, 6.0% (w/w) sodium lauryl sulphate (SDS), and 0.8% (w/w) n-octane as the separation medium, the fat-soluble vitamins A palmitate, E acetate, and D3 were baseline separated within 11 min. With strongly suppressed EOF, the polarity of the separation voltage was reversed (positive electrode at the outlet); the n-octane micro droplets surrounded by negatively charged SDS molecules migrated towards the detector. The aqueous part of the microemulsion was modified with 20% (w/w) 2-propanol to improve partition between the n-octane phase and the surrounding aqueous medium. The fat-soluble vitamins were separated in order of decreasing hydrophobicity with a high migration time stability (repeatable within 0.1% RSD). Excellent accuracy and precision were obtained when the system was applied for the determination of vitamin E acetate in commercial vitamin tablets; quantitative data corresponded to 97.0% of label claim, intra-day results varied within 1.72% RSD (n=6), and inter-day results varied within 3.22% RSD (n=5).

Buffers↗

Development of a simple in-vial liquid-phase microextraction device for drug analysis compatible with capillary gas chromatography, capillary electrophoresis and high-performance liquid chromatography.

A simple, inexpensive and disposable device for liquid-phase microextraction (LPME) is presented for use in combination with capillary gas chromatography (GC), capillary electrophoresis (CE) and high-performance liquid chromatography (HPLC). 1-4 ml samples of human urine or plasma were filled into conventional 4-ml vials, whereafter 15-25 microl of the extraction medium (acceptor solution) was filled into a short piece of a porous hollow fiber and placed into the sample vial. The drugs of interest were extracted from the sample solutions and into the small volumes of acceptor solution based on high partition coefficients and were preconcentrated by a factor of 30-125. For LPME in combination with GC, the porous hollow fiber was filled with 15 microl n-octanol as the acceptor solution. Following 30 min of extraction, the organic acceptor solution was injected directly into the GC system. For LPME in combination with CE and HPLC, n-octanol was immobilized within the pores of the hollow fiber, while the internal volume of the fiber was filled with either 25 microl of 0.1 M HCl (for extraction of basic compounds) or 25 microl 0.02 M NaOH (for acidic compounds). Following 45 min extraction, the aqueous acceptor solution was injected directly into the CE or HPLC system. Owing to the low cost, the extraction devices were disposed after a single extraction which eliminated the possibility of carry over effects. In addition, because no expensive instrumentation was required for LPME, 10-30 samples were extracted in parallel to provide a high number of samples per unit time capacity.

Blood Chemical Analysis↗

Liquid-phase microextraction and capillary electrophoresis of acidic drugs.

Vial liquid-phase microextraction (LPME) combined with capillary electrophoresis (CE) was evaluated for the determination of the acidic drugs ibuprofen, naproxen, and ketoprofen present in water samples and in human urine. The 2.5 mL samples containing the drugs were filled into conventional vials and subsequently acidified by 250 microL of 1-10 M HCl. Porous hollow fibers of polypropylene containing 25 microL of an aqueous solution of 0.01-0.1 M NaOH (acceptor solution) and with dihexyl ether immobilized in the pores of the wall were placed into each of the samples. The acidic drugs were extracted from the acidified sample solutions into the dihexyl ether phase, in the pores of the hollow fiber, and further into the alkaline acceptor solution forced by high partition coefficients. The drugs were extracted almost quantitatively (75-100% extraction efficiency) from the 2.5 mL samples and into the 25 microL acceptor solutions, providing 75-100 times preconcentration. The acceptor solutions were collected for automated CE analysis, which enabled the drugs to be detected down to the 1 ng/mL level.

Anti-Inflammatory Agents, Non-Steroidal↗

Capillary gas chromatography coupled with microplasma mass spectrometry for organotin speciation.

Gas chromatography was coupled with microplasma mass spectrometry for selective detection of organotin compounds. The microplasma ion source was a capacitively coupled radiofrequency helium plasma, which was located inside the high vacuum area of the mass spectrometer. Only 1-3 ml min-1 of helium carrier gas from the gas chromatograph was necessary for sustaining the plasma while 0.15-1.5 ml min-1 of hydrogen was added as reagent gas. Hydrogen was applied for prevention of carbon deposition and served to minimize the interactions between tin and the fused-silica inner surface of the microplasma ion source. Both carbon and tin were detected as positively charged atomic ions, which were expelled from the microplasma ion source and directly focused by electrostatic lenses towards the quadrupole mass analyzer. Tin exhibited high selectivity to carbon (> 10(4)) and a detection limit of 3.5 pg s-1.

Gas Chromatography-Mass Spectrometry↗

Liquid-liquid-liquid microextraction for sample preparation of biological fluids prior to capillary electrophoresis.

Methamphetamine as a model compound was extracted from 2.5-mL aqueous samples adjusted to pH 13 (donor solution) through a thin phase of 1-octanol inside the pores of a polypropylene hollow fiber and finally into a 25-microL acidic acceptor solution inside the hollow fiber. Following this liquid-liquid-liquid microextraction (LLLME), the acceptor solutions were analyzed by capillary zone electrophoresis (CE). Extractions were performed in simple disposable devices each consisting of a conventional 4-mL sample vial, two needles for introduction and collection of the acceptor solution, and a 8-cm piece of a porous polypropylene hollow fiber. From 5 to 20 different samples were extracted in parallel for 45 min, providing a high sample capacity. Methamphetamine was preconcentrated by a factor of 75 from aqueous standard solutions, human urine, and human plasma utilizing 10(-1) M HCl as the acceptor phase and 10(-1) M NaOH in the donor solution. In addition to preconcentration, LLLME also served as a technique for sample cleanup since large molecules, acidic compounds, and neutral components were not extracted into the acceptor phase. Utilizing diphenhydramine hydrochloride as internal standard, repetitive extractions varied less than 5.2% RSD (n = 6), while the calibration curve for methamphetamine was linear within the range 20 ng/microL to 10 micrograms/mL (r = 0.9983). The detection limit of methamphetamine utilizing LLLME/CE was 5 ng/mL (S/N = 3) in both human urine and plasma.

Diphenhydramine↗

Strategies for the capillary electrophoretic separation of indole alkaloids in Psilocybe semilanceata.

While the hallucinogenic mushrooms Psilocybe semilanceata have previously been analyzed for the indole alkaloids psilocybin and baeocystin by capillary zone electrophoresis (CZE) at pH 11.5, the present work focused on the development of an alternative and complementary capillary electrophoretic method for their identification. Owing to their structural similarity and zwitterionic nature, the compounds were difficult to resolve based on different interactions with cationic or anionic micelles. However, while the attempts with micellar electrokinetic chromatography (MEKC) were unsuccessful, rapid derivatization with propyl chloroformate and reanalysis by CZE at pH 11.5 was effective to support identification of the two indole alkaloids. Psilocin was difficult to analyze by CZE at pH 11.5 owing to comigration with the electroosmotic flow. For this compound, the pH of the running buffer was reduced to 7.2 to effectively enhance the electrophoretic mobility.

Alkaloids↗

Analysis of vitamin formulations by electrokinetic chromatography utilizing tetradecylammonium ions as the pseudostationary phase.

A recently proposed method for the separation of fat-soluble vitamins by electrokinetic chromatography was further developed and investigated in the present study. The separation medium consisted of acetonitrile-water (80:20 v/v) and contained 80 mM tetradecylammonium bromide (TDA+); the content of acetonitrile served to maintain the hydrophobic vitamins dissolved during electrophoresis, while the TDA+ ions served as the pseudostationary phase. With the cathode placed at the outlet of the capillary, the fat-soluble vitamins were separated based on different hydrophobic interactions to the TDA+ ions and migrated in order of decreasing hydrophobicity prior to the electroosmotic flow. Migration time stability was significantly enhanced by the addition of 4 mM borate to the separation medium. The separation system was validated for the determination of vitamin E acetate in commercial tablets; quantitative results deviated by less than 3.5% from specified values, varying by less than 2.5% relative standard deviation (RSD) for within-day experiments, and by less than 6.5% RSD during between-day experiments. The separation system was compatible with injection solvents ranging in polarity from water to tetrahydrofuran, and was even capable of separating the water-soluble vitamins B1, B2, B12, and nicotinamide.

Chromatography, Micellar Electrokinetic Capillary↗

Capillary gas chromatography combined with atomic emission detection for the analysis of DDT and metabolites.

Capillary gas chromatography with atomic emission detection (GC-AED) was evaluated for the determination of DDT and metabolites in biological samples. Utilizing chlorine-selective detection at 479 nm, DDT, DDE, and DDD were quantified down to the 20 ng/g (fat weight) level (S/N = 10) in cod liver oil, while the detection, limit was 6 ng/g (S/N = 3). With splitless injection performed in the pressure programmed mode, DDT and related compounds were quantified based on a single chlorine calibration curve (universal calibration). The quantitative data obtained by GC-AED were in excellent accordance with similar results from capillary gas chromatography with electron capture detection (GC-ECD), while the procedure for calibration was simplified with the former technique.

Chromatography, Gas↗

Determination of psilocybin in Psilocybe semilanceata by capillary zone electrophoresis.

A capillary zone electrophoretic (CZE) method was developed for the rapid determination of psilocybin in Psilocybe semilanceata. Following a simple two step extraction with 3.0+2.0 ml methanol, the hallucinogenic compound was effectively separated from matrix components by CZE utilizing a 10 mM borate-phosphate running buffer adjusted to pH 11.5. The identity of psilocybin was confirmed by migration time information and by UV spectra, while quantitation was accomplished utilizing barbital as internal standard. The calibration curve for psilocybin was linear within 0.01-1 mg/ml, while intra-day and inter-day variations of quantitative data were 0.5 and 2.5% R.S.D., respectively. In addition to psilocybin, the method was also suitable for the determination of the structurally related compound baeocystin.

Agaricales↗