PubMed Health⌕ Search

Biomedical subjects

S Pennaforte

Publications and source records attributed to S Pennaforte.

6 recordsLinked to original sources

Trimetazidine: a new concept in the treatment of angina. Comparison with propranolol in patients with stable angina. Trimetazidine European Multicenter Study Group.

1. Trimetazidine has a direct anti-ischaemic effect on the myocardium without altering the rate x pressure product or coronary blood flow. 2. The effects of trimetazidine (20 mg three times daily) were compared with those of propranolol (40 mg three times daily) in a double-blind parallel group multicentre study in 149 men with stable angina. 3. Reproducibility of exercise performance was verified during a 3 week run-in placebo washout period. All patients had > 1 mm ST-depression on exercise test. 4. After 3 months, similar anti-anginal efficacy was observed between the trimetazidine (n = 71) and propranolol (n = 78) groups. No significant differences were observed between trimetazidine and propranolol as regards anginal attack rate per week (mean difference P-TMZ: 2; 95% CI: -4.4, 0.5) and exercise duration (mean difference P-TMZ: 0 s; 95% CI: -33, 34) or time to 1 mm ST segment depression (mean difference P-TMZ: 13 s; 95% CI: -24, 51). Heart rate and rate x pressure product at rest and at peak exercise remained unchanged in the trimetazidine group but significantly decreased with propranolol (P < 0.001 in all cases). With both drugs there was a trend to decreased ischaemic episodes in the 46% patients who experienced ambulatory ischaemia on Holter monitoring. Six patients stopped trimetazidine and 12 propranolol. Of these, five in each group were withdrawn because of deterioration in cardiovascular status. 5. The results suggest that trimetazidine and propranolol at the doses studied have similar efficacy in patients with stable angina pectoris.(ABSTRACT TRUNCATED AT 250 WORDS)

Angina Pectoris↗

Myocardial cytoprotection during percutaneous transluminal coronary angioplasty.

Transluminal coronary angioplasty (PTCA) is a well defined controlled model inducing regional myocardial ischaemia in man. Direct cardiac anti-ischaemic effects of anti-anginal drugs can be assessed by intracoronary injection of small doses which do not affect systemic parameters. Trimetazidine (TMZ) has recently been shown to improve anginal symptoms without modifying haemodynamic variables. A randomized, double-blind, placebo-controlled trial was conducted in 20 patients to study the effects of TMZ on the severity of myocardial ischaemia during PTCA of the left anterior descending coronary artery. Five minutes after a first successful dilation (D0), a control balloon inflation (D1) was performed until onset of ischaemic signs on both the intracoronary (i.c.) and precordial ECG. Two minutes later, patients received either trimetazidine 6 mg or placebo i.c. Another inflation (D2) was performed 5 min after D1. No differences were found between the two groups regarding responses in heart rate, systemic and i.c. pressures during the study. TMZ decreased maximum ST segment shift at D2 as compared to D1 (0.8 +/- 0.1 vs 1.4 +/- 0.3 mV, P = 0.023) and delayed its onset (46 +/- 4 vs 36 +/- 5 s, P = 0.024). TMZ also decreased maximum T wave changes (1.06 +/- 0.24 vs 2.19 +/- 0.3 mV, P = 0.001), and significantly reduced the area under the curve (AUC:mV.s-1) of the i.c. ST segment and T wave changes during balloon inflation (P = 0.002 and P < 0.001 respectively). Placebo had no effect on any of these parameters.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon, Coronary↗

[Innocuousness of the limited reuse of injection materials by insulin-dependent diabetics].

A survey was conducted in 120 insulin-dependent diabetics to determine their routine daily procedure for insulin injection and the possible reuse of the material employed. Aseptic precautions were usually sufficient, half of the diabetic patients (51.6%) conforming with the overall rules for hygiene generally recommended. Spontaneous reuse of injection material was rare (10/120), and local incidents as a result of reuse infrequent: pain from the 3rd injection in 2 patients and an abdominal abscess in a third case due to total lack of asepsis rules. Insulin injections in 37 insulin-dependent diabetics admitted to hospital care were administered throughout their stay by means of plastic syringes and needles used 3 times consecutively. The mean number of needles-syringes used per diabetic was 7.3, representing a total of 813 injections. Infectious sequelae were not observed and minor local incidents (pain, pruritus) were rare and unrelated to the reuse of equipment. Limited reuse, under satisfactory conditions of asepsis, of material termed for "once only use" appears to be free from risk particularly with respect to infection. Generalization of this practice will provide substantial economy in the treatment of diabetes.

Diabetes Mellitus, Type 1↗