PubMed Health⌕ Search

Biomedical subjects

S Quan

Publications and source records attributed to S Quan.

87 records · Page 5Linked to original sources

Interferon alpha therapy in patients with chronic type C hepatitis: changes of serum ALT, anti-HCV & HCV-RNA.

BACKGROUND: After the discovery of type C hepatitis virus, the studies on this virus are extensively progressing. The treatment of this viral infection is also widely progressing. Among many agents, recombinant interferon alpha therapy is generally accepted as an effective single agent. To evaluate the efficacy of interferon and to observe the changes of serum aminotransferase (ALT), antibody to hepatitis C virus (anti-HCV) and HCV ribonucleic acid (HCV-RNA), we treated 10 patients with chronic type C hepatitis for 6 months. METHODS: Patients were randomly divided into 2 groups: 5 patients in group A received interferon and the other 5 in group B received no therapy. Interferon was administered at a dose of 3 million units (MU) daily for the first month and thrice weekly for the following 5 months, and followed up for 2 years. RESULTS: In group A, serum ALT returned to normal in 4: 3, starting at the first month and one at the 3rd month of therapy and maintained normal throughout the follow-up period. In contrast, serum ALT level persistently fluctuated in 4 patients in group B. In one patient, serum ALT returned to normal one and a half years later. Regardless of therapy, serum anti-HCV titer remained unchanged in all patients. However, HCV-RNA, using polymerized chain reaction (PCR), became undetectable in all responded patients and in one untreated patient whose serum ALT returned to normal spontaneously. CONCLUSION: This study suggested that interferon alpha therapy in patients with chronic type C hepatitis may be clinically effective. Our study also indicated that the detection of HCV-RNA by PCR is useful to predict the prognosis of chronic type C hepatitis.

Adult↗

New-generation RIBA hepatitis C strip immunoblot assays.

Second-generation hepatitis C virus (HCV) ELISAs are currently in use in Europe and have been submitted for approval in the United States. These new assays contain additional antigens from the putative nucleocapsid and NS-3 regions of the HCV genome in addition to the c100-3 antigen present in first-generation ELISAs. A supplementary test, the second-generation RIBA HCV strip immunoblot assay (2-RIBA HCV SIA) has also been developed. The strip immunoblot assay uses four recombinant HCV antigens [5-1-1 (NS-4), c100-3 (NS-4), c33c (NS-3), and c22-3 (NS-3) (nucleocapsid)] slot blotted on nitrocellulose. Screening of random volunteer blood donors with the Ortho second-generation HCV ELISA (ORTHO HCV 2.0 ELISA) indicates that a substantial change in the repeat reactive donor population is observed with the new test. Two notable features of this change are: (1) A large number of samples reactive in the 2-RIBA HCV SIA for the second-generation antigens, c33c and c22-3, are detected by the ORTHO HCV 2.0 ELISA; (2) the percentage of ORTHO HCV 2.0 ELISA reactive specimens found indeterminate (reactive for only one HCV antigen) by the 2-RIBA HCV SIA is higher than in first-generation HCV ELISAs (approximately 25 vs. 5%). In addition, ORTHO HCV 2.0 ELISA repeat reactive, 2-RIBA HCV SIA indeterminate samples are dominated by reactivity to c22-3 instead of c100-3, which is the case for first-generation HCV ELISA repeat reactive samples. Resolution of 2-RIBA HCV SIA indeterminate samples as either containing anti-HCV antibodies or not, is important in both diagnostic and blood screening environments, especially where donor notification is required. Our approach to resolution of these troublesome samples evolved from initial work with HCV peptides. Early studies with an experimental strip immunoblot assay containing 5 peptides from the nucleocapsid, E2 (NS-1), NS-4, and NS-5 regions of the viral genome indicated that peptides from the nucleocapsid and NS-4 regions of the genome could provide additional evidence for the presence of anti-HCV antibodies with good specificity, but other peptides suffered from poor specificity. In addition, no immunoreactive peptide from the NS-3 (c33c) region of the virus is available, presumably because the major epitope(s) of this key second-generation antigen is a conformational determinant.(ABSTRACT TRUNCATED AT 400 WORDS)

Blood Transfusion↗

New generation RIBA hepatitis C strip immunoblot assays.

Second generation hepatitis C virus (HCV) Elisas are currently in use in Europe and have been submitted for approval in the United States. These new assays contain additional antigens from the putative nucleocapsid and NS-3 regions of the HCV genome in addition to the c100-3 antigen present in first generation Elisas. A supplementary test, the second generation RIBA (Chiron Co trademark) HCV strip immunoblot assay (2-RIBA HCV SIA) has also been developed. The strip immuno-blot assay uses four recombinant HCV antigens (5-1-1 [NS-4], c100-3 [NS-4], c33c [NS-3], and c22-3 [NS-3 [nucleocapsid]) slot blotted on nitrocellulose. Screening of random volunteer blood donors with the Ortho (Ortho Diagnostic Systems trademark) second generation HCV Elisa (2-Ortho HCV Elisa) indicates that a substantial change in the repeat reactive donor population is observed with the new test. Two notable features of this change are: i) a large number of samples reactive in the 2-RIBA HCV SIA for the second generation antigens, c33c and c22-3, are detected by the 2-Ortho HCV Elisa; ii) the percentage of 2-Ortho HCV Elisa reactive specimens found indeterminate (reactive for only one HCV antigen) by the 2-RIBA HCV SIA is higher than in first generation HCV Elisas (approximately 25 versus 5%). In addition, 2-ortho HCV Elisa repeat reactive, 2-RIBA HCV SIA indeterminate samples are dominated by reactivity to c22-3 instead of c100-3 which is the case for first generation HCV Elisa repeat reactive samples.(ABSTRACT TRUNCATED AT 250 WORDS)

Enzyme-Linked Immunosorbent Assay↗

Heterosexual co-transmission of hepatitis C virus (HCV) and human immunodeficiency virus (HIV).

OBJECTIVES: To determine the prevalence of antibodies to hepatitis C virus (HCV) in female sexual partners of multitransfused men with hemophilia and to compare the frequency of transmission of HCV and human immunodeficiency virus (HIV). STUDY DESIGN: Cross-sectional measurement of HCV and HIV antibodies. SETTING: Ten hemophilia treatment centers. PATIENTS: A total of 234 female sexual partners of 231 multitransfused men with hemophilia. MEASUREMENTS AND MAIN RESULTS: The prevalence of antibodies to HCV (anti-HCV) among female sexual partners of HCV-positive men was 5 of 194 (2.6%). Anti-HIV prevalence among female sexual partners of HIV-positive men was 25 of 196 (12.8%). Five (3%) of the 164 female sexual partners of HIV-positive/HCV-positive men were infected with HCV compared with none of the 30 female sexual partners of HIV-negative/HCV-positive men. Twenty-one (13%) of the 164 female sexual partners of HIV-positive/HCV-positive men were infected with HIV compared with 4 (13%) of 32 female sexual partners of HIV-positive/HCV-indeterminate men. The co-infected men were five times more likely to transmit both viruses than would be expected by chance (P = 0.01). When a single virus was transmitted to a female sexual partner, it was more often HIV than HCV (18 of 164 compared with 2 of 164, P = 0.001; odds ratio, 8.5; 95% Cl, 2.2 to 33.1). CONCLUSIONS: The higher prevalence of HCV in female sexual partners of men with hemophilia than in blood donor and other low-risk groups suggests that there is a low level of sexual transmission. Male to female sexual transmission of HCV is less efficient than that of HIV. The frequency of HCV transmission to sexual partners is five times higher when HIV is also transmitted, suggesting that HIV may be a cofactor for the sexual transmission of HCV.

Adult↗

Confirmation of hepatitis C virus infection by new four-antigen recombinant immunoblot assay.

A new four-antigen recombinant immunoblot assay (4-RIBA) for confirmation of hepatitis C virus (HCV) C-100 enzyme-linked immunosorbent assay (ELISA) reactivity was tested in stored serum samples (1984-86) of blood donors and recipients and compared with results from polymerase chain reaction (PCR) analysis of fresh (1990) plasma samples in donors and recipients from the original study. Of 37 HCV C-100 ELISA-positive blood products, 8 were 4-RIBA positive, of which 7 were implicated in post-transfusion non-A, non-B hepatitis (PT-NANBH) and/or PCR confirmed recipient HCV infection. Of 9 recipients with PT-NANBH, 8 were reactive in 4-RIBA (6 positive and 2 indeterminate). With fresh plasma samples, 3 donors and 6 recipients who were 4-RIBA positive were also PCR positive. 4 4-RIBA indeterminate and 78 4-RIBA negative samples of donors and recipients were PCR negative. Of 6 4-RIBA positive recipients, 5 were PCR positive four to six years later. 1.6% of the 383 recipients became chronically infected with HCV. The new 4-RIBA represents a candidate confirmation test to discriminate between infective and non-infective HCV C-100 ELISA-positive blood donors.

Base Sequence↗

The use of a recombinant immunoblot assay in the interpretation of anti-hepatitis C virus reactivity among prospectively followed patients, implicated donors, and random donors.

Samples from prospectively followed recipients, their respective donors, and a cohort of random donors were used to evaluate the specificity and efficacy of a recombinant immunoblot assay (RIBA) as an adjunct to anti-hepatitis C virus (HCV) testing by enzyme immunoassay (EIA). RIBA reacted (RIBA+) in 100 percent of patients who developed hepatitis associated with anti-HCV seroconversion documented by EIA and in 100 percent of the EIA-positive (EIA+) donors implicated in these cases. In contrast, RIBA reacted in none of 10 recipients who were EIA+ but did not develop hepatitis, in none of 7 EIA+ patients with hepatitis B or cytomegalovirus infection, in 33 percent of EIA+ donors who were not implicated in hepatitis transmission, and in 37 percent of EIA+ random donors. Hence, the vast majority of EIA+ individuals who have ancillary evidence of HCV infection react on RIBA, whereas the majority of EIA+ individuals in low-risk settings do not react (RIBA-negative, or RIBA-). There was a strong association between RIBA reactivity and the presence of a surrogate marker (elevated alanine aminotransferase [ALT] and/or antibody to hepatitis B core antigen); 43 percent of RIBA+ implicated donors had a surrogate marker as compared to none of 14 EIA+, RIBA- donors. Among EIA+ random donors, 77 percent of those with a surrogate marker were RIBA+, as compared with 29 percent of those without a surrogate marker. In addition, in EIA+ donors, RIBA reactivity correlated with the extent of ALT elevation; 86 percent of those with an ALT greater than 135 IU per L were RIBA+ compared with 18 percent of those with an ALT less than 30 IU per L.(ABSTRACT TRUNCATED AT 250 WORDS)

Blood↗

Risk factors in hepatitis C virus-infected blood donors.

Risk factors of parenteral and nonparenteral exposure to hepatitis C virus (HCV) infection were studied in 125 blood donors in The Netherlands who were positive for anti-HCV on enzyme-linked immunosorbent assay (ELISA). Risk factors were related to confirmatory test results of four-antigen recombinant immunoblot assay (4-RIBA) and polymerase chain reaction (PCR) of the HCV 5' untranslated region. Twelve (10%) of the 125 anti-HCV C100 ELISA-positive blood donors were 4-RIBA positive. Eleven (92%) of 12 4-RIBA-positive blood donors were PCR positive, and all 113 remaining 4-RIBA-negative or -indeterminate donors were PCR negative. Eleven (92%) of 12 4-RIBA-positive blood donors had a risk factor of parenteral exposure, as compared to 17 (15%) of 113 4-RIBA-negative or -indeterminate donors. The prevalence of confirmed HCV infection among Amsterdam blood donors is calculated at 0.04 percent; parenteral exposure appears to be the major risk factor for HCV infection.

Blood Donors↗

Response of human glioblastoma cells to recombinant interleukin-2.

We investigated the ability of glioma cells to respond to T cell-derived lymphokines. The growth of astrocytoma and mixed glioblastoma cell lines, as assessed by DNA synthesis, was inhibited in the presence of supernatants derived from mitogen-stimulated human T cells, an HTLV-II-transformed human T cell line, Mo, and human interleukin-2 (IL-2). The mixed glioblastoma cell line, 138-MG-C, was subjected to limiting dilution analysis, and two cell lines (5D7, 5C5) were derived which were homogeneous with respect to staining for galactocerebroside (GalC) (100%). These two GalC+ glioblastoma cell lines proliferated in the presence of high concentrations of recombinant human interleukin-2 (RIL-2). Additionally, these cell lines bear receptors for the IL-2 molecule as determined by immunofluorescent staining with various anti-IL-2 receptor antibodies.

Brain Neoplasms↗

Local control with pre-operative radiotherapy alone versus "sandwich" radiotherapy for rectal carcinoma.

Forty-nine patients with primary adenocarcinoma of the rectum, clinically localized to the pelvis were treated with pre-op radiotherapy (RT) 1500 cGy/5 fx with AP/PA fields, followed by immediate curative resection. Patients staged as Astler-Coller B2, C1, or C2 were considered for post-op RT, 4140 cGy/23 fxs with a 4-field technique. There were 47 evaluable patients in this non-randomized study. Two groups of patients were analyzed, namely pre-op RT only (24 patients) and combined pre- and post-op ("sandwich") RT (23 patients). Two patients with pre-op RT only were considered inevaluable for recurrence because they died NED at 1 and 7 mo. All patients have been followed for greater than 1 year; 77% have been followed for greater than 2 yr. There has been only one local recurrence (LR), surprisingly in a Stage A pre-op RT patient who had no residual tumor in the final operative specimen. In the pre-op group which included 10 B2s, and 1 C2, 1500 cGy in 5 days (equivalent to 1940 cGy by the NSD formulation) was associated with no local recurrence. No distant metastases (DM) have developed in this group. In the "sandwich" RT group, which included 3 B2s, 1 C1, 17 C2s, and 1 D (localized to the pelvis, i.e. ovary), there were no LRs and 7 DMs (1 B2 and 6 C2s). Actuarial survival is 92% in the pre-op RT group at 2 and 3 yr, and 82% in the "sandwich" group at 2 and 3 yr. There have been no serious early or late complications related to RT in our pre-op group. The use of 1500 cGy in 5 days as pre-op RT with immediate surgery may prove, upon longer follow-up, to be sufficient for increasing local control, with minimum morbidity, in patients with B2 disease. Patients with C2 disease are being controlled locally with the "sandwich" regimen, but it is not clear whether pre-op RT alone may be adequate in this group as well. We are now addressing this question in a randomized study.

Adenocarcinoma↗

Malignant anal lesions.

Explore the source record for details and available documents.

Adenocarcinoma, Mucinous↗

Automated RIBA HCV strip immunoblot assay: a novel tool for the diagnosis of hepatitis C virus infection in hemodialysis patients.

Hemodialysis (HD) patients remain a high-risk group for hepatitis C virus (HCV) infection. Serological assays (enzyme-linked immunosorbent assays, ELISAs) are the only tests currently approved by the Food and Drug Administration in the United States for the diagnosis of HCV. The RIBA HCV Strip Immunoblot Assay (SIA) is an established method for supplemental testing of repeat reactive hepatitis C ELISA patients on HD. However, the current manual procedure is labor intensive, requiring subjective band scoring and result interpretation. Recently, the automated CHIRON RIBA HCV Processor System has been designed to perform RIBA supplemental testing. The CHIRON RIBA HCV Processor System consists of a bench-top instrument that provides objective evaluation of the RIBA immunoblot strips, by measuring the light differentially reflected from the developed bands and white background, creating a density of reflectance. The CHIRON RIBA HCV Processor System assesses the intensity of each of the reactive bands in relation to the intensity of the internal control bands on each RIBA HCV strip. Comparison between processor and manual protocols was performed using a large (n = 200) cohort of ELISA 3.0 HCV negative and positive patients on maintenance HD. The test characteristics of RIBA HCV 3.0 SIA were identical with manual and automated runs. The relative intensity values of antigenic bands by the CHIRON RIBA HCV 3.0 Processor System between anti-HCV positive and negative patients were significantly different; only 15 of 784 (1.9%) antigenic bands had borderline reactivities. The correlation of test results between manual and automated runs was very high (kappa value 0.989). Among positive results by RIBA HCV 3.0 SIA, there was a strong concordance between manual and automated runs with regard to the pattern of reactivity (kappa value 0.943). The discordant results between manual and automated protocols were attributable to increased variability of antigen scores close to the cutoff value for both tests. In conclusion, the CHIRON RIBA HCV 3.0 Processor System is capable of performing RIBA HCV 3.0 SIA in the HD population accurately with minimal operator involvement. The test characteristics of RIBA HCV 3.0 SIA were identical by manual and automated runs. There was a strong correlation between the results of the manual and automated runs; the few discordant results between the two procedures were mostly due to increased variability of antigen scores close to the cutoff value for both tests. The Centers for Disease Control and Prevention in the USA have recently included chronic HD patients among those persons for whom routine HCV testing is recommended; HCV-infected patients on HD often have a high rate of indeterminate results by manual RIBA technology which is operator dependent for band scoring and result interpretation. The CHIRON RIBA HCV 3.0 Processor System may be very useful for supplemental anti-HCV testing of ELISA repeat reactive specimens in clinical practice within dialysis units.

Hepatitis C, Chronic↗