PubMed Health⌕ Search

Biomedical subjects

S R Jefferts

Publications and source records attributed to S R Jefferts.

4 recordsLinked to original sources

Single-atom optical clock with high accuracy.

For the past 50 years, atomic standards based on the frequency of the cesium ground-state hyperfine transition have been the most accurate time pieces in the world. We now report a comparison between the cesium fountain standard NIST-F1, which has been evaluated with an inaccuracy of about 4 x 10(-16), and an optical frequency standard based on an ultraviolet transition in a single, laser-cooled mercury ion for which the fractional systematic frequency uncertainty was below 7.2 x 10(-17). The absolute frequency of the transition was measured versus cesium to be 1,064,721,609,899,144.94 (97) Hz, with a statistically limited total fractional uncertainty of 9.1 x 10(-16) the most accurate absolute measurement of an optical frequency to date.

Journal Article↗

Standards of time and frequency at the outset of the 21st century.

After 50 years of development, microwave atomic clocks based on cesium have achieved fractional uncertainties below 1 part in 10(15), a level unequaled in all of metrology. The past 5 years have seen the accelerated development of optical atomic clocks, which may enable even greater improvements in timekeeping. Time and frequency standards with various levels of performance are ubiquitous in our society, with applications in many technological fields as well as in the continued exploration of the frontiers of basic science. We review state-of-the-art atomic time and frequency standards and discuss some of their uses in science and technology.

Journal Article↗

Measurement of dynamic end-to-end cavity phase shifts in cesium-fountain frequency standards.

We have measured a previously unobserved systematic frequency shift in our cesium-fountain frequency standard, NIST-F1. This shift, predicted theoretically previously, mimics the well-known end-to-end phase shift in atomic beam standards when synchronous thermal transients are present. Detuning the microwave cavity several megahertz from resonance reduces this effect to the deltaf/f = 1o(-16) level.

Letter↗

Testing the stability of fundamental constants with the 199Hg+ single-ion optical clock.

Over a two-year duration, we have compared the frequency of the 199Hg+ 5d(10)6s (2)S(1/2)(F=0)<-->5d(9)6s(2) (2)D(5/2)(F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These measurements show that any fractional time variation of the ratio nu(Cs)/nu(Hg) between the two frequencies is smaller than +/-7 x 10(-15) yr(-1) (1sigma uncertainty). According to recent atomic structure calculations, this sets an upper limit to a possible fractional time variation of g(Cs)(m(e)/m(p))alpha(6.0) at the same level.

Journal Article↗