PubMed Health⌕ Search

Biomedical subjects

S R Needham

Publications and source records attributed to S R Needham.

6 recordsLinked to original sources

Multidimensional single-molecule imaging in live cells using total-internal-reflection fluorescence microscopy.

We have developed a wide-field total-internal-reflection fluorescence microscope capable of imaging single molecules in live cells, resolved in both wavelength and polarization. We show fluorescence resonance energy transfer between single pairs of fluorescent molecules bound to signaling receptors in the plasma membrane of live cells and demonstrate the importance of polarization discrimination in addition to wavelength separation.

Animals↗

Performance of a pentafluorophenylpropyl stationary phase for the electrospray ionization high-performance liquid chromatography-mass spectrometry-mass spectrometry assay of cocaine and its metabolite ecgonine methyl ester in human urine.

A pentafluorophenylpropyl (PFPP) bonded silica column has been used for the high-performance liquid chromatography-electrospray ionization-mass spectrometry-mass spectrometry assay (HPLC-ESI-MS-MS) of cocaine (COC) and its metabolite, ecgonine methyl ester (EME) in human urine. COC and EME were used as model basic solutes to demonstrate that a PFPP phase yields excellent results for the assay and validation of drugs in biological fluids. The assay was linear over three orders of magnitude (1.0-1000 ng/ml) and precision and accuracy of the assay was 4 and 15%, respectively. The limit of detection (LOD) for COC and EME was 1.6 and 2.8 pg on column, respectively. In addition, only a simple 1:10 dilution of the urine was necessary for the sample preparation procedure thus saving time on a laborious extraction step. The major advantage of the PFPP phase was the enhancement of the ESI-MS signal by providing good retention and good peak shape of COC and EME with a mobile phase of 90% acetonitrile. The MS signal for COC was a factor of 12 times greater on the PFPP phase than on the C18 phase.

Calibration↗

The high performance liquid chromatography electrospray ionization mass spectrometry analysis of diverse basic pharmaceuticals on cyanopropyl and pentafluorophenylpropyl stationary phases.

Cyanopropyl (CN) and pentafluorophenylpropyl (PFPP) modified silica columns give good retention and good peak shape for the high performance liquid chromatography/electrospray ionization/mass spectrometry (HPLC/ESI/MS) analysis of several classes of basic drugs. These phases enhance the ESI-MS signal by providing good retention of basic drugs with a mobile phase containing 90% acetonitrile. With C18 columns, in order to achieve good retention of basic drugs, only a mobile phase containing less than 40% acetonitrile can be used. Higher concentrations of acetonitrile produce a larger MS signal in the ESI process; the MS signal was a factor of 9 and 12 times greater on the CN and PFPP phases when compared with the C18 phase for the analysis of codeine. The C18 phase required only 4.0-6.0% acetonitrile to obtain the same retention time for codeine. The CN and PFPP stationary phases can be used for the analysis of a range of basic drugs, including many compounds which are poorly retained on the popular C18 and C8 stationary phases. Applications of CN and PFPP columns in the HPLC/ESI/MS of basic drugs include the analysis of antimalarials, such as quinine, bronchodilators, such as salbutamol and tulobuterol, cardioactive drugs, such as procainamide and beta-blockers, tricyclic antidepressants (TCAs), such as protriptyline and trimipramine and alkaloids, such as morphine and codeine. The CN and PFPP phases are also useful for the analysis of bufuralol and its metabolite, hydroxy-bufuralol. All the above analyses were performed using the same mobile phase, 90% acetonitrile; thus the HPLC method development process was expedited. The CN and PFPP phases also gave reproducible retention times and peak shape after more than 8 h of analyses.

Chromatography, High Pressure Liquid↗

Optimized stationary phases for the high-performance liquid chromatography-electrospray ionization mass spectrometric analysis of basic pharmaceuticals.

Stationary phases were investigated for HPLC coupled with electrospray ionization mass spectrometry (ESI-MS) for the analysis of basic drugs. Tricyclic antidepressants (TCAs) and beta-blockers were used as model solutes. The functional groups, pentafluorophenyl (PFP), OH, CN or CH3 were attached to the silica via a propyl chain. The effects of these stationary phases as well as C8 and C18 phases on retention and peak shape of the basic drugs were studied. The CN and PFP phases adequately retained (tR of 2 to 6 min) the basic drugs when the mobile phase was composed of 90% acetonitrile, whereas with the C4, C8 and C18 phases, less than 40% acetonitrile had to be used to provide adequate retention of the basic drugs. Because acetonitrile provides better desolvation in ESI than an aqueous solvent, it produces an increased MS signal. As an example of the HPLC-ESI-MS analysis of the beta-blocker, pindolol, on a CN phase, the use of 90% acetonitrile in the mobile phase increased the ESI-MS signal by 790% when compared to a C18 phase which could use only 5% acetonitrile in the mobile phase for retention of the solute. In addition, the CN and PFP phases provided better peak shape than the OH phase and the hydrophobic phases (C4, C8 and C18) and ion-pairing or ion-suppressing agents were not required. The retention behavior of the TCAs and beta-blockers on each of the phases is described.

Adrenergic beta-Antagonists↗

Rapid confirmation/quantitation of cocaine and benzoylecgonine in urine utilizing high performance liquid chromatography and tandem mass spectrometry.

A rapid, but sensitive and selective method for confirmation and quantitation of benzoylecgonine (BZE) and cocaine (COC) in urine by fast-gradient liquid chromatography/tandem mass spectrometry (LC/MS/MS) is described. The chromatographic separation was performed on a reversed phase column employing fast-gradient techniques. Matrix prepared standards, blanks, and QC's were filtered then aliquots were transferred into a 96 well plate. Injection volumes of 25 microL were made onto the analytical column, with the flow diverted from the atmospheric pressure ionization source for the first 0.5 min of the analysis. Simultaneous multiple reaction monitoring (MRM) of three discrete transitions for each compound were used to identify BZE and COC. Quantitation was achieved utilizing the most prominent parent-daughter transition and internal standard calibration techniques. The coefficients of variation (CV) for the analysis of these drugs ranged from 0.6% to 6.8% at a concentration of 150 ng/mL (n = 155). This method suggests that fast-gradient LC/MS/MS may be suitable for routine confirmation of immunoassay cocaine-positive samples.

Adult↗

Direct plasma injection for high-performance liquid chromatographic-mass spectrometric quantitation of the anxiolytic agent CP-93 393.

A direct plasma injection method has been developed for the rapid analysis of drugs in biological fluids. A new generation restricted access media column specifically designed to accommodate direct injection of plasma and other fluids is utilized for on-line HPLC-ESI-MS analysis. For rapid analysis the on-line extraction column is linked to a HPLC-ESI-MS system. Good results are obtained for the quantitation of CP-93 393 and deuterated internal standard over the range of 10-1000 ng/ml. The lower limit of detection for the assay was 58 pg injected on column. Accuracy and precision values are 9.0% or better over the entire range of the assay. In addition, more than 200 injections (100 microl) were performed per column with unattended, automated analysis.

Anti-Anxiety Agents↗