PubMed Health⌕ Search

Biomedical subjects

S R Quint

Publications and source records attributed to S R Quint.

11 recordsLinked to original sources

Heart period variability during vagal nerve stimulation.

Vagal nerve stimulation is an emerging therapy for epilepsy, yet little is known regarding the effects of this stimulation on heart period variability. We selected 10 patients (two female, eight male) who were receiving high-frequency, high-intensity left vagal nerve stimulation for intractable epilepsy. Electrocardiogram data were recorded for a 7 min baseline, 2.5 min of stimulation and a 7 min post-stimulation period. We found no significant changes in average heart period, instantaneous changes of successive R-to-R intervals greater than 50 ms or fractal dimension. We also found no significant changes in the total power in the 0.0-0.04 Hz, 0.04-0.12 Hz and 0.2-0.4 Hz bands with stimulation of the left vagus nerve. This study suggests that left vagal nerve stimulation has little acute effect on the cardiac rhythm or heart period variability.

Adolescent↗

Heart period variability in sleep.

Analysis of heart period variability is a dynamic noninvasive technique to quantify the autonomic control over the heart period. We recorded electroencephalographic, electro-oculographic, electromyographic and electrocardiographic data from 10 normal subjects during sleep using an ambulatory polysomnographic monitor. R-R intervals were determined for 10 min segments of electrocardiographic data from wakefulness, stage 2 sleep, slow wave sleep and REM sleep. Average heart period, instantaneous changes greater than 50 msec and fractal dimension were calculated and the time domain and phase plots were depicted. The R-R interval time domain plots were subsequently analyzed using the discrete Fourier transform. We found sleep stage specific, time domain and frequency domain changes in heart period variability, particularly using spectral analysis of heart period. Increased power in the 0.2-0.4 Hz band was associated with stage 2 sleep when compared to awake and slow wave sleep states. Power in the 0.0-0.04 and 0.04-0.12 Hz bands was increased in association with REM sleep when compared to non-REM sleep, and slow wave sleep had diminished power in all frequency bands. Our results support other investigations demonstrating stage 2 sleep is associated with increased parasympathetic influences and REM sleep is associated with increased sympathetic and neurohumoral influences. We feel that spectral analysis of heart period variability is an effective noninvasive method to quantify changes in the autonomic influences over the heart during sleep.

Adult↗

A comparison of the noise sensitivity of nine QRS detection algorithms.

The noise sensitivities for nine different QRS detection algorithms were measured for a normal, single-channel lead II, synthesized ECG corrupted with five different types of synthesized noise. The noise types were electromyographic interference, 60 Hz powerline interference, baseline drift due to respiration, abrupt baseline shift, and a composite noise constructed from all of the other noise types. The percentage of QRS complexes detected, the number of false positives, and the detection delay were measured. None of the algorithms were able to detect all QRS complexes without any false positives for all of the noise types at the highest noise level. Algorithms based on amplitude and slope had the highest performance for EMG-corrupted ECG. An algorithm using a digital filter had the best performance for the composite noise corrupted data.

Algorithms↗

A real-time system for the spectral analysis of the EEG.

We have developed an inexpensive and portable system for processing multiple channels of electroencephalograms (EEG) in real-time to assist the electroencephalographer in identifying subtle changes in these data, particularly in the interpretation of long records. Up to 16 channels of data are spectrally decomposed with a selection of bandwidth, windows, scaling methods, epoch averaging, and smoothing options available. The resulting power spectral estimate may be displayed or printed in a variety of formats, including color encoding of selectable spectral bands. Both the sampled EEG and its spectra may be stored for off-line reprocessing, for archiving, or for statistical analysis in the time or frequency domains.

Analog-Digital Conversion↗

Automated data acquisition and analysis of neural evoked potentials.

A software system to collect, analyze and store trains of neural evoked potentials is presented. Real-time waveform capture permits sampling of a variable-duration data window of 6 to 399.6 ms with a sample delay accurately adjustable up to 1 001 ms (20 microseconds resolution). The digitized representation of each waveform is stored for individual analysis. Off-line processing determines 17 parameters of each waveform, including an arrow-selected amplitude and time. Individual processing of waveforms preserves all degrees of freedom for statistical analysis across waveforms. Ensemble averages may optionally be formed from the individual waveforms with processing performed on the averaged responses. The software provides MENU-selectable support functions including stimulus-to-artifact timing, storage and retrieval of data and calculated parameters, digital display of waveforms, data calibration and gain modification, table referenced data editing, file management, simple statistics, hardcopy output, and optional database interfacing with output formatted for compatibility with a statistics package (SAS).

Animals↗

Stabilization of the thalamocortical motor system by cerebellar stimulation.

Epilepsy typifies instability in a complex control system. We have previously identified parameters of the thalamocortical motor system of the cat which correlate with epileptiform activity and are controlled by common anticonvulsants. This study is concerned with the control of such parameters by cerebellar stimulation, potencially promoting stability within the motor system. Under computer control, stimuli were delivered to both ventrolateral thalamus and cerebellar cortex, with multichannel recording of evoked responses obtained from sensorimotor cortex. Cortical evoked responses were plotted as an excitability curve (mean response amplitude as a function of pulse interval) or a family of threshold curves (mean response amplitude as a function of stimulus amplitude at various fixed intervals). The present study reveals that cerebellar epidural stimulation can reduce both the height and duration of the excitability curve, as well as increase the response threshold and reduce the saturation level of the threshold curve. The degree and direction of these parameter changes are dependent on the frequency, polarity, and amplitude of cerebellar stimulation, with the amount of parameter change exceeding that achieved by monotoxic doses of anticonvulsants. These data suggest that control of parameters related to excitability and threshold in the thalamocortical motor system may be the means by which cerebellar stimulation accomplishes control of clinical seizures.

Animals↗

On-line analysis of neuromuscular bioelectric potentials.

A computer system is presented which provides for on-line data capture and analysis of evoked end-plate potentials and action potentials, and on-line data capture with off-line analysis of spontaneously occurring miniature end-plate potentials at the end-plate region of the neuromuscular junction. Sampling of evoked waveforms begins after an adjustable delay following the stimulus. Spontaneously occurring waveforms are captured by 'freezing' the contents of a circular buffer. The software provides MENU selectable support functions including storage and retrieval of data and calculated parameters, analog and digital display of waveforms, data calibration and gain modification, data editing, file management, and hardcopy output. Calculated parameters of the waveform are optionally placed in a data base file by the analysis programs. The data base may be used for editing, arithmetic operations, and subsetting of variables as well as statistical analysis and plotting of any selected variables.

Action Potentials↗

Enhancement of cerebrovascular effect of CO2 by hypoxia.

Internal carotid blood flow, taken as an index of cerebral blood flow (CBF); arterial pressure; and respiratory O2 and CO2 concentrations, were measured in halothane (1%)-anesthetized, paralyzed and mechanically ventilated rabbits. CBF was determined at end-tidal CO2 of 4% (normocapnia) and 8%, as inspired O2 [O2]I) was varied stepwise over the range of 6.5 to 92%. Normocapnic CBF was constant over the range of 15 to 92% [O2]I, but it increased significantly to 240% and 380% of control when [O2]I was at 10% and 6.5%, respectively. Cerebrovascular response to CO2 was constant over the range of [O2]I tested, except for a significant elevation to 180% of control at [O2]I of 10%.

Animals↗