PubMed HealthSearch

Biomedical subjects

S S Mehta

Publications and source records attributed to S S Mehta.

13 recordsLinked to original sources

Intracoronary stent implantation via the brachial approach: a technique to reduce vascular bleeding complications.

To reduce the incidence of vascular complications of intracoronary stent implantation, we used the brachial approach. We attempted implantation of the Palmaz-Schatz stent via the brachial artery approach at 10 lesions in 9 patients. Stent delivery was successful at 8 lesions. Balloon angioplasty was successfully performed in the 2 failed cases, 1 of whom required surgical repair of the brachial artery. Intravenous anticoagulation was uninterrupted from the time of stent placement until therapeutic prothrombin times from oral warfarin therapy were obtained. Neither acute nor long-term major bleeding occurred in the 9 patients. There were no embolic events, myocardial infarctions, or deaths. One subacute thrombosis occurred, and the patient underwent bypass surgery. To evaluate the risks and benefits of the brachial approach, we compared these 9 patients with 41 who had stent placement by the femoral approach during the same period. Lesion characteristics were similar in these 2 groups. There were no significant differences in the success rate or angiographic outcome between the 2 groups. Seven (17%) patients in the femoral group had vascular access complications requiring surgery, compared with 1 (11%) in the brachial group. No patient in the brachial group required transfusion, compared with all 7 of the patients who had femoral vascular complications. The potential reduction in bleeding complications makes the brachial approach to stent implantation attractive in selected patients.

Aged

Palmaz-Schatz stent implantation in stenosed saphenous vein grafts: clinical and angiographic follow-up.

Balloon-expandable stents may reduce the restenosis rate following coronary angioplasty. To evaluate this potential in saphenous vein grafts, 26 patients with 30 discrete stenoses underwent conventional balloon dilation and successful Palmaz-Schatz stent implantation as part of a multicenter trial. All patients had resolution of their angina following the procedure. In a mean 5-month follow-up period, 14 patients (54%, 16 lesions) had repeat arteriography; two patients (14%) developed recurrent ischemia ascribed to their venous grafts from in-stent restenosis (2 of 16 lesions, 13%). Two asymptomatic patients (8%) died: one from cardiac arrest (stent patent) and one from stroke (no autopsy). The clinical recurrence rate (cardiac death, myocardial infarction, bypass surgery, repeat angioplasty, or symptom recurrence) was 15%. These preliminary results show trends toward an improved primary success rate with combined vein graft angioplasty/stenting and a lower restenosis rate in stented saphenous vein grafts, but continuing follow-up will be needed to verify these observations.

Aged

Holmium laser angioplasty after failed coronary balloon dilation: use of a new solid-state, infrared laser system.

A new solid-state laser system was used in a case of saphenous vein graft occlusion untreatable by standard very low-profile balloon angioplasty. The 2100 nm infrared pulsed thulium/holmium: YAG laser successfully recanalized an obtuse marginal bypass graft without complications. The holmium laser has several advantages over excimer systems and may prove an effective adjunct or alternative to coronary balloon angioplasty.

Aged

Giant left atrium.

Explore the source record for details and available documents.

Cardiomegaly