Basic design and construction of the Vienna FES implants: existing solutions and prospects for new generations of implants.

We can distinguish 3 generations of FES implants for activation of neural structures: 1. RF-powered implants with antenna displacement dependent stimulation amplitude; 2. RF-powered implants with stabilised stimulation amplitude; and 3. battery powered implants. In Vienna an 8-channel version of the second generation type has been applied clinically to mobilisation of paraplegics and phrenic pacing. A 20-channel implant of the second generation type for mobilisation of paraplegics and an 8-channel implant of the third generation type for cardiac assist have been tested in animal studies. A device of completely new design for direct stimulation of denervated muscles is being tested in animal studies. There is a limited choice of technologically suitable biocompatible and bioresistant materials for implants. The physical design has to be anatomically shaped without corners or edges. Electrical conductors carrying direct current (D.C.) have to be placed inside a hermetic metal case. The established sealing materials, silicone rubber and epoxy resin, do not provide hermeticity and should only embed DC-free components. For electrical connections outside the hermetic metal case welding is preferable to soldering; conductive adhesives should be avoided. It is advisable to use a hydrophobic oxide ceramic core for telemetry antenna coils embedded in sealing polymer. Cleaning of all components before sealing in resin is of the utmost importance as well as avoidance of rapid temperature changes during the curing process.

Animals↗

Preparation of a skeletal muscle ventricle in sheep: severe damage to the Latissimus dorsi muscle due to mobilization before preconditioning.

As part of a study examining the use of a skeletal muscle ventricle for cardiac assistance in sheep, a new concept of muscle preconditioning was put into practice. We aimed to produce a latissimus dorsi muscle (LDM) capable of performing chronic work immediately after the construction of a skeletal muscle ventricle. The left LDM was detached from the thoracic wall, divided longitudinally and reattached in situ to achieve vascular delay. The right LDM was left unaffected. Thereafter, preconditioning of both LDM was started according to the clinically approved stimulation protocol for cardiomyoplasty. Preconditioning of the unaffected right LDM in situ resulted in a complete muscle fiber transformation with no signs of degeneration or necrosis. Mobilization of the left LDM before preconditioning led to a distinct damage of the muscle. During conditioning, the increase in burst duration from 2 to 3 impulses in sheep A and from 3 to 5 impulses in sheep B resulted in a homogenous degeneration of the muscle fibers of the left LDM. Histomorphological analysis showed a dramatic increase in the percent perimysial and endomysial connective tissue. The applied concept of muscle prefabrication proved to be a failure. Muscle splitting and mobilization followed by vascular delay and in situ conditioning as a concept of muscle prefabrication should be strictly avoided.

Animals↗

Irregularity of the ventricular rhythm during atrial fibrillation: effect of slow atrioventricular nodal pathway ablation.

BACKGROUND: The contribution of dual atrioventricular (AV) nodal pathway physiology to the irregularity of the ventricular rhythm during atrial fibrillation has not been clarified. HYPOTHESIS: This study was performed to assess the effects of slow AV nodal pathway ablation on the irregularity of the ventricular rhythm during atrial fibrillation. METHODS: Irregularity of the ventricular rhythm was quantified using analysis of heart rate variability. In 20 patients with AV nodal reentrant tachycardia, absolute heart rate variability during atrial fibrillation was quantified before and after slow AV nodal pathway ablation by the standard deviation of all NN intervals (SDNN). Relative heart rate variability was determined by computing the coefficient of variation, SDNN normalized for the standard deviation of the mean ventricular cycle length (MVCL-AF). RESULTS: The slope of the regression between MVCL-AF and SDNN was significantly more gradual after slow pathway ablation (slope 0.39 vs. 0.23, p < 0.001). Coefficient of variation increased in 12 patients with heart rates > 120 beats/min at baseline (18.6 +/- 3.9 vs. 22.1 +/- 2.7% MVCL-AF, p < 0.05), but decreased in 8 patients with heart rates < 120 beats/min at baseline (25.6 +/- 3.1 vs. 22.2 +/- 2.2% MVCL-AF, p = 0.05). Furthermore, coefficient of variation correlated with MVCL-AF only at baseline (slope 0.034, r = 0.66), but no relation was found after slow pathway ablation (slope 0, r = 0). CONCLUSIONS: Slow AV nodal pathway ablation alters the relation between absolute heart rate variability and mean ventricular rate during atrial fibrillation and eliminates cycle length dependency of relative heart rate variability. These data indicate that dual AV nodal pathway physiology contributes to the irregularity of the ventricular rhythm during atrial fibrillation.

Adult↗

Multifunctional implantable nerve stimulator for cardiac assistance by skeletal muscle.

Different methods are used, clinically and experimentally, to assist severely impaired heart function by means of skeletal muscle. The efficiency of these methods is restricted by skeletal muscle losing strength after transpositioning and during conditioning and not being sufficiently resistant to fatigue. This is mainly due to the nonphysiological activation of the nerves by electrical stimulation. We have developed a battery operated, ECG triggered multichannel implant that is capable of implementing various advanced stimulation techniques. The stimulator can activate 2 skeletal muscles via the motor nerves. It allows for application of multichannel stimulation methods, i.e., carousel stimulation and sequential stimulation, as well as the programming of optimized pulse trains. Synchronization delay and burst duration can be automatically and dynamically adapted to the heart rate. The multichannel stimulator is hermetically sealed in a titanium case. Its calculated life span on the basis of the integrated battery is 3-5 years, depending on the programmed stimulation parameters. The implant dimensions are 65 x 17 mm (diameter x height), and it weighs 93 g. The implant has been tested in vitro as well as in vivo.

Animals↗

Long-term electromyogram recording from the posterior cricoarytenoid muscle as a potential biological trigger for phrenic pacing: results of an animal study.

Diaphragm pacing has been used to restore respiration in approximately 1,000 patients worldwide suffering from high quadriplegia or from central alveolar hypoventilation syndrome. Compared with conventional mechanical ventilation, electrophrenic respiration (EPR) reduces the risk of pulmonary infections and increases the mobility of patients. Voluntary activation of the pacemaker during speech would improve patients' quality of life and allow application of EPR in a more physiological way. An animal study was performed to investigate the electromyogram (EMG) of the posterior cricoarytenoid (PCA) muscle and the movement of the glottis via impedance measurement (electroglottography) with the aim to examine reproducibility and stability of the recordings from the PCA muscle as a potential biological trigger for a phrenic pacemaker. The EMG of the PCA muscle was recorded via implanted electrodes for a 200 day period. The EMG signal proved stable for that period, artifacts caused by movements can be suppressed, and swallowing can be detected. In contrast, impedance measurement to detect movement of the glottis proved not useful. Based on the results of this study, the use of the PCA EMG as a biological trigger for a phrenic pacemaker has to be considered a realistic option.

Animals↗

Battery-powered implantable nerve stimulator for chronic activation of two skeletal muscles using multichannel techniques.

Chronic activation of skeletal muscle is used clinically in representative numbers for diaphragm pacing to restore breathing and for dynamic graciloplasty to achieve fecal continence. The 3 different stimulation techniques currently used for electrophrenic respiration (EPR) all apply high frequency powered implants. It was our goal to make these stimulation methods applicable for EPR by a battery-powered nerve stimulator that would maximize the patient's freedom of movement. Additionally, the system should allow the implementation of multichannel techniques and alternating stimulation of 2 skeletal muscles as a further improvement in graciloplasty. Generally, the developed implantable nerve stimulator can be used for simultaneous and alternating activation of 2 skeletal muscles. Stimulation of the motor nerve is achieved by either single channel or multichannel methods. Carousel stimulation and sequential stimulation can be used for graciloplasty as well as for EPR. For EPR we calculated an operating time of the implant battery of 4.1 years based on the clinically used stimulation parameters with carousel stimulation. The multichannel pulse generator is hermetically sealed in a titanium case sized 65 x 17 mm (diameter x height) and weighs 88 g.

Diaphragm↗

Personal computer supported eight channel surface stimulator for paraplegic walking: first results.

Today functional electrical stimulation (FES) is used among other treatments to restore hand and arm function, to restore mobility of the lower extremities, for phrenic pacing, and in cardiomyoplasty. Common to all FES applications is that they require careful setup of stimulation parameters. To improve these tasks, personal computer (PC) based software for stimulation parameter evaluation and data acquisition was written. First, the described software was used to mobilize paraplegic patients in conjunction with an 12C bus controlled 8 channel surface stimulator. Electrodes were placed on each leg on the m. quadriceps and m. gluteus for hip and knee extension and the peroneal nerve to elicit flexion reflex. The fourth channel was used to correspond to subjects' individual needs. The stimulation patterns for standing up, walking, and sitting down easily could be set up and optimized by adjusting up to 128 stimulation parameters in a task-specific way.

Electric Stimulation Therapy↗

MYOSTIM-FES to prevent muscle atrophy in microgravity and bed rest: preliminary report.

Long-term flights in microgravity cause atrophy and morphological changes of skeletal muscles. Training with mechanical devices is insufficient regarding the required time to exercise and space for devices. The objective of this project is to develop a passive training method based on functional electrostimulation (FES) to preserve muscle mass and fiber composition with minimal impairment to the cosmonaut. For a pilot experiment on the MIR space station, a suitable 8 channel FES device was developed. It consists of electrode trousers that carry surface electrodes and cables, 2 interconnected 4 channel stimulators, and a laptop personal computer (PC) for stimulator programming and processing compliance data. An automatic extensive training of 4 muscle groups of the lower extremities is performed for 6 h/day, with 1 s on and 2 s off tetanic contractions at 20-30% of maximum tetanic muscle force. The synchronous activation of antagonists of the thigh and lower leg prevents uncoordinated movements.

Bed Rest↗

[Modular PC-based data acquisition and processing system for biological signals].

The data acquisition system described here is designed for biomedical research and permits the recording of up to eight biological signals simultaneously. A personal computer using the Windows 95 operating system is employed for data monitoring, data processing and analysis during experiments. The system has been designed for reliability, economy, flexibility and ease of handling, with the aim of achieving universal application. To avoid interface incompatibility, problems with transfer protocols and the data formats of commercially available products, analog signals are used for further processing. The individual input channels are electrically isolated from one another and the PC to avoid ground loops, and for reasons of safety. An isolated voltage supply is available for pre-amplifiers and bridges. A bandwidth of 0-5 kHz and the maximum sampling rate of 12.5 kHz suffice to pick up higher frequency signals such as EMG and ENG. The modular software and hardware concepts permit the use of almost any desktop or laptop PC as a central processing unit. The PC handless documentation, data acquisition, data analysis and the preparation of publications. If needed, further analytical functions can be added in modular form. Finally, the option of saving data in the ASCII format permits processing of results with such standard software packages as Excel, Access, Matlab and Origin.

Signal Processing, Computer-Assisted↗

Battery-powered miniature implant for electrical nerve stimulation.

The range of application of implantable stimulators in functional electrical stimulation (FES) for therapeutic purposes and for the restoration of lost or damaged functions has steadily grown within the last 20 years. Each time a clinically used method is improved, a new field of FES application explored or basic research conducted, animal experiments are needed to check and evaluate the findings and results. It is precisely for this use that the stimulation system described in this paper was developed. The battery-powered single-channel stimulator can be used for the excitation of motor and sensory nerves with monophasic or biphasic impulses. All parameters and functions are programmable via the bidirectional telemetry circuit. Implant programming is achieved by a laptop computer, supported by a graphical user interface, instead of by a specially designed programmer. The maximum settings of the stimulation parameters are: frequency 100 Hz, monophasic pulse duration 0.8 ms, biphasic pulse duration 1.6 ms, stimulation current 3 mA. The implant volume was reduced to 2 cm3 (length 23 mm, width 13 mm, height 7.5 mm), lowering the weight to 3.6 g. Due to this small volume the implant can be used in small animals. The power supply via battery obviates the need for transcutaneous tunneling or permanent external high-frequency senders and facilitates the keeping of the animals.

Animals↗

Useful applications and limits of battery powered implants in functional electrical stimulations.

Battery powered stimulation implants have been well-known for a long time as heart pacemakers. In the last few years, fully implantable stimulators have been used in the field of functional electrical stimulation (FES) for applications like dynamic cardiomyoplasty and electro-stimulated graciloplasty for fecal incontinence. The error rate of battery powered implants is significantly smaller than that for conventional stimulator systems, and the quality of life for the patients is increased because the need for an external power and control unit is eliminated. The use of battery powered implants is limited by the complexity of the stimulation control strategies and the battery capacity. Therefore, applications like the stimulation of lower extremities for walking, cochlea stimulation, or direct muscle stimulation cannot be supported. The improvement of implantable batteries, microcontrollers, and ultralow power products is ongoing. In the future, battery powered implants will also meet the requirements of complex applications. Systems for restoration of hand and breathing functions after spinal cord injury can be the next field of use for battery powered implants. For these purposes, we developed a battery powered multichannel implant with a sufficient life span for phrenic pacing. The problems during development and the limits of this system are described in this paper.

Cardiomyoplasty↗

Computer aided adjustment of the phrenic pacemaker: automatic functions, documentation, and quality control.

Electrical stimulation of the phrenic nerves of patients with complete ventilatory insufficiency with the Vienna respiratory pacemaker has been in clinical use since 1983. During the adjustment of stimulation parameters with this device, the following problems have occurred: for some measurements like the recruitment curve, series of complete inspiration cycles have to be stimulated, which causes the danger of muscle fatigue for unconditioned patients. The documentation is completed predominantly by hand, taking time and increasing the possibility of error. As a first step to solve these problems, we developed a new stimulation and measurement system. It consists of a PC with data acquisition hardware, the necessary sensors, and amplifier circuitry. The implanted stimulator is controlled via the parallel interface. The new system offers some advantages: computer control shortens the time for measurement and documentation, and the stress on the patient and the risk of error is reduced; synchronized measurement makes it possible to use single stimulation pulses instead of bursts and ramps to reduce diaphragm fatigue; digital signal processing improves measurement results and reproducibility; and help functions and self tests are provided, together with a graphical user interface. We used sensors for air flow, diaphragm EMG, and acceleration, on up to 8 channels simultaneously. Combined sample rates of up to 100 kS/s were possible. The system could be adapted for other uses involving functional electrical stimulation with our implantable nerve stimulators. Using this equipment saves a lot of effort, and the adjustment process can be focused on improved stimulation results and better performance for the patient. Current research is studying implementation of automatic functions like acquisition of stimulation thresholds. This could result in a predominantly automated adjustment of the phrenic pacemaker and even in a closed-loop controlled system in the future.