Effects of aprotinin on hemorrhagic complications in ARDS patients during prolonged extracorporeal CO2 removal.

The effects of aprotinin, a broad-based proteinase inhibitor, in the management of hemorrhagic complications during prolonged venovenous extracorporeal CO2 removal in patients with adult respiratory distress syndrome are not evaluated. In two patients, aprotinin infusion was added to heparin to treat bleeding, occurring after few days of bypass and responsible for respiratory and hemodynamic deterioration. After aprotinin infusion (loading dose of 2 x 10(6) kIU followed by a continuous infusion of 5 x 10(5) kIU/h) combined with heparin, bleeding vanished until the end of bypass.

Adult

[Etomidate modifies hemodynamic response to fentanyl in patients with impaired left ventricular function].

The haemodynamic effects and the side-effects of anaesthesia using high doses of fentanyl were compared in two groups of 12 patients each. All the patients had poor left ventricular function and were scheduled for elective coronary artery bypass graft surgery or valvular replacement. Patients were randomly assigned to either group. In group EF, patients were given 5 micrograms.kg-1 of fentanyl, followed by 0.3 mg.kg-1 of etomidate. Once they had lost consciousness, they were given 15 mg of pancuronium and 25 micrograms.kg-1 of fentanyl over a 5 min period. Patients in group F received the full 30 micrograms.kg-1 dose of fentanyl over a 5 min period, followed by 15 mg of pancuronium. The patients were intubated 2 min after the end of the fentanyl infusion. They were mechanically ventilated with 100% oxygen. Anaesthesia was maintained with a continuous infusion of fentanyl (total dose 100 micrograms.kg-1). The usual haemodynamic parameters were monitored and calculated, as well as pain during injection of the drugs, myoclonia, chest wall rigidity and the time to loss of consciousness. The two groups were comparable with respect to age, weight, height and surgery. One third of the patients in group EF complained of pain during etomidate injection. The time required to loose consciousness was shorter in group EF (55 +/- 16 sec) than in group F (177 +/- 56 sec) (p < 0.001). The cardiac index decrease in group EF (2.0 +/- 0.4 l.min-1.m-2 vs. 1.9 +/- 0.4 l.min-1.m-2) (p < 0.05), respectively between the time just before tracheal intubation (T1), and 10 min after tracheal intubation (T3).(ABSTRACT TRUNCATED AT 250 WORDS)

Anesthesia, Intravenous

High-dose alfentanil for myocardial revascularization: a hemodynamic and pharmacokinetic study.

It has been suggested that high plasma levels of alfentanil are required in order to control hemodynamic responses to noxious stimuli in patients undergoing myocardial revascularization. The present study was designed to determine the hemodynamic profile in 10 patients and the time course of alfentanil plasma concentrations and pharmacokinetics (7 patients) during and following coronary artery surgery using alfentanil administration based on an overdosage principle. Premedication consisted of lorazepam, 0.07 mg/kg, given 2 hours before surgery. Ten milligrams of alfentanil was given over 5 minutes for anesthesia induction, followed by an infusion of 60 mg/h until sternotomy and 30 mg/h up to skin closure. Additional 5-mg boluses were given prior to noxious intraoperative events. Hemodynamic measurements were performed prior to cardiopulmonary bypass. Blood was sampled simultaneously prebypass and then during the postbypass period for determination of alfentanil plasma levels. The very high alfentanil plasma concentrations achieved provided satisfactory intraoperative conditions in most, but not all, patients. Recovery time was short, despite the large amounts of narcotic used. It is concluded that very high doses of alfentanil associated with lorazepam premedication resulted in hemodynamic stability and markedly elevated narcotic plasma concentrations in most patients. Such plasma levels seem to provide satisfactory anesthetic conditions.

Alfentanil

[Autotransfusion].

Explore the source record for details and available documents.

Blood Transfusion, Autologous

[Clinical experience with the Saint Jude prosthesis. Results over a period of 7 years].

Between January, 1979 and December, 1985, 193 Saint Jude medical valves (SJM) were implanted in 165 patients (74 male, 91 female) aged from 14 to 78 years (mean age: 49 years). 101 patients underwent aortic valve replacement, 36 had mitral valve replacement and 21 had multiple valve replacement. Fitting with an SJM prosthesis was a primary emergency operation for 15 patients (9%) and a reoperation for 49 patients (31%). A concomitant surgical procedure was carried out in 39 patients (24%). The overall peri-operative mortality rate was 9% (15 patients), this figure falling to 5% (6/112 patients) when emergency surgery and reoperations are excluded. No patient was lost sight of. Mean follow-up was 37 +/- 3 months (range: 4 to 84 months), for a total duration of 413 years/patient. Five patients died of heart disease during the follow-up period, representing a mortality rate of 1.2% per year/patient. The actual survival rate was calculated as 90% at 1 year and 83% at 7 years. During that period 7 thromboembolic accidents occurred among 5 patients (actual rate: 1.7 accident per 100 years/patient). Two mechanical valve desinsertions requiring reoperation were recorded. Altogether, the actuarial rate of patients without any post-operative complication was 88% at 1 year and 65% at 7 years. Functional improvement was dramatic since 94% of survivors are now in class I or II, whilst 67% of patients were in class III or IV prior to surgery. It may be concluded that the mid-term

Actuarial Analysis

[Aneurysm of the aortic arch. Surgical therapy. 60 cases].

Sixty patients with aortic arch aneurysm have been operated upon at the Foch Medico-Surgical Centre between 1964 and 1984. This period can be subdivided into: January, 1964 to December, 1975 (24 cases) and January, 1976 to April, 1984 (36 cases). The technique used (closure by patch or segmental replacement prosthesis) depended on the type of lesion encountered. In most cases, the cardiopulmonary bypass was between the femoral artery and the right atrium. After experimenting with different methods, we now protect the brain by selective cold blood carotid perfusion, using independent circuit and heat-exchanger. Operative mortality was 12% in series I (1964-1975) and 0% in series II (1975-1984) patients. Hospital mortality was 25% in series I and 13% in series II patients. The improvements obtained during the last few years, using cold blood carotid perfusion and circulatory arrest in the lower half of the body, have made it possible to perform open distal anastomoses. This method ensures excellent brain protection and short cardiopulmonary bypass period.

Adult

Circulatory responses to thiopentone and tracheal intubation in patients with coronary artery disease. Effects of pretreatment with labetalol.

The haemodynamic responses to induction and tracheal intubation have been studied in patients with coronary artery disease randomly assigned to a labetalol pretreatment group (n = 14) or to a placebo group (n = 16). Twelve hour before operation, treated patients received a bolus dose of labetalol 0.5 mg kg-1 followed by a constant infusion of 0.1 mg kg-1 h-1 i.v. Anaesthesia was induced with thiopentone and phenoperidine, and intubation performed following the administration of suxamethonium. At intubation, the changes in heart rate (P less than 0.01), mean arterial pressure (P less than 0.05) and rate-pressure product (P less than 0.01) were significantly smaller in the labetalol group compared with the placebo group. Labetalol pretreatment appears satisfactory and may be useful in patients with coronary artery disease who have a normal left ventricular ejection fraction.

Anesthesia, General

[Repeated valvular replacements].

After more than two decades of cardiac valve replacement surgery, the number of reoperations has increased and third or even fourth replacements are no longer rare occurrences. Of the 2072 valves prostheses implanted at the Hôpital Foch between 1970 and December 1984, 134 (6.4%) have been changed at least once and 27 prostheses (1.3%) have been replaced three or more times in 23 patients. Eighteen patients were operated on three times and 5 patients 4 times, a total of 73 operations. Ten patients had aortic valve prostheses, 7 had mitral valve prostheses and 6 had double aortic and mitral valve prostheses. The technical difficulties due to previous cardiac surgery were not great or easily surmounted as every procedure was performed by a median sternotomy and only 2 out of 50 required cannulation of the femoral vessels for cardiopulmonary bypass. The repair itself consisted of simple valve replacement in 3 out of 4 cases (30 single and 3 double valve replacements, 3 valve reinsertions). The other operations required more complex techniques such as remodelling of the ring of insertion or the use of a valved tube. None of the patients died in the operating theatre. However, 3 patients died during the hospital period (13%) and there were 2 late deaths (10%) and 1 patient (5%) was lost to follow-up. The 17 survivors were followed up for 3 to 148 months (average 42 months). Half the patients are now in functional Classes I or II of the NYHA classification. These results show that repeated valve replacement has an acceptable operative risk.(ABSTRACT TRUNCATED AT 250 WORDS)

Aortic Valve

[Dissection of the ascending aorta after aortic valve replacement].

From October, 1969 to December, 1982, 1117 aortic valve replacements were performed at the Foch Medico-Surgical Centre. Five of these operations (0.4%) were followed, within 6 months to 6 years (mean 37 months), by acute dissection of the whole ascending aorta with a varying degree of extension further down. Such accidents raise problems of aetiology, diagnosis, treatment and possibly prevention. All 5 patients had an emergency operation with prosthetic replacement of the ascending aorta; in some cases the 2 cylinders were glued to the distal and proximal aortic stumps. The other forms of treatment were related to the lesions encountered. All patients survived and underwent follow-up angiography after 6 months to 5 1/2 years. Lesions of cystic necrosis of the media were regularly found at histology. In every case during the first operation the surgeon reported that the aorta was dilated or particularly fragile. The question therefore arises as to whether ascending aortas that are fragile and of more than 5 cm in diameter should be systematically replaced.

Adult

[Destruction of the bundle of His with the neodymium-YAG laser. Preliminary experimental study].

Experiments with a new technique for His bundle interruption were performed on 10 dogs. The atrioventricular node-His bundle track was destroyed by means of a neodymium-yttrium-aluminium-garnet laser (Nd-YAG laser) used in continuous emission at 35 watts. The operation was conducted under simple clamping of the vena cava for a mean period of 1 minute 30 seconds, and 30 seconds were required for destruction of the His bundle. An atrio-ventricular block was obtained immediately in all dogs and persisted for more than 3 weeks. No accident was recorded. The Nd-YAG laser therefore appears to be a reliable technique and could be used for surgical treatment of arrhythmias.

Aluminum