PubMed Health⌕ Search

Biomedical subjects

S Shrader

Publications and source records attributed to S Shrader.

4 recordsLinked to original sources

The organic aerosols of Titan.

A dark reddish organic solid, called tholin, is synthesized from simulated Titanian atmospheres by irradiation with high energy electrons in a plasma discharge. The visible reflection spectrum of this tholin is found to be similar to that of high altitude aerosols responsible for the albedo and reddish color of Titan. The real (n) and imaginary (k) parts of the complex refractive index of thin films of Titan tholin prepared by continuous D.C. discharge through a 0.9 N2/0.1 CH4 gas mixture at 0.2 mb is determined from x-ray to microwave frequencies. Values of n (approximately equal to 1.65) and k (approximately equal to 0.004 to 0.08) in the visible are consistent with deductions made by ground-based and spaceborne observations of Titan. Many infrared absorption features are present in k (lambda), including the 4.6 micrometers nitrile band. Molecular analysis of the volatile component of this tholin was performed by sequential and non-sequential pyrolytic gas chromatography/mass spectrometry. More than one hundred organic compounds are released; tentative identifications include saturated and unsaturated aliphatic hydrocarbons, substituted polycyclic aromatics, nitriles, amines, pyrroles, pyrazines, pyridines, pyrimidines, and the purine, adenine. In addition, acid hydrolysis produces a racemic mixture of biological and non-biological amino acids. Many of these molecules are implicated in the origin of life on Earth, suggesting Titan as a contemporary laboratory environment for prebiological organic chemistry on a planetary scale.

Aerosols↗

Experimental study on rotator cuff repair.

It was the purpose of the experimental study to use laboratory experience to verify the effectiveness of different methods used to repair the rotator cuff. The sheep was used as an animal model because its infraspinous tendon is the most similar to that in the human. Three static trials were conducted using Instron machines, comparing the repair systems used most by the same authors in their clinical work, the hold of the suturing wires with two different threading procedures in the bone tunnels and two types of knotting, and the breakage loading of the suturing wires in the two different miniplate systems. The authors conclude that tendinous anchoring must be entrusted to reinforced suturing systems (modified SCOI and Mason Allen), the threading of wires in pairs in a single bone tunnel makes surgery easier and shortens the amount of time required, with threading of wires similar to or better than threading with a single wire. There are no differences in breakage loading of the wire at the level of the holes in the two miniplates considered in this study.

Animals↗