PubMed Health⌕ Search

Biomedical subjects

S Spinner

Publications and source records attributed to S Spinner.

7 recordsLinked to original sources

Documented home apnea monitoring: effect on compliance, duration of monitoring, and validation of alarm reporting.

The objectives of this study were to: (1) measure patient compliance with monitoring, (2) validate parental reports of alarms at home, (3) examine monitoring duration, and (4) compare documented monitor records with the traditional pneumogram to evaluate patients for monitor discontinuation. During the 1-year period from January through December, 1992, 114 infants were followed up with documented monitoring. Simultaneously, 113 infants were followed up with conventional monitors. Infants were premature, or victims of apparent life-threatening episodes (ALTE), or siblings of SIDS victims. Monitors recorded all episodes of apnea greater than 15 seconds and bradycardia less than 80 beats per minute. All families were contacted biweekly by telephone. Downloads were performed at regular intervals. Monitor downloads were compared with simultaneous pneumograms to assess the accuracy of a long-term, intermittent event-recording system versus short-term (6- to 12-hour) continuous recording. All families were highly compliant with the use of home monitoring. Although Caucasian families used the monitors more often than non-Caucasian families, all groups used the monitor > 75% of the time. True episodes were verified in 38% of patients by monitor downloads. Only 7.4% of all recorded events were true events. Of the real events, 51.2% were apneas of 16-20 seconds. No significant differences were found in overall duration of monitoring between documented and nondocumented monitors. In the premature infants, the duration of monitoring was significantly reduced in those infants found to have no true episodes over those with real events at home. Readmission for ALTE was reduced in infants with documented monitors. Premature infants without events were monitored an average of 24 fewer days (P = 0.03). Computerized monitor downloads were found to be equally, if not more, sensitive than pneumograms in evaluating infants for monitor discontinuation. Documented monitoring offers a viable alternative to traditional monitoring and pneumograms in assisting clinicians and families in evaluating their infant's progress. By accurately assessing compliance, distinguishing true from false alarms, and decreasing the need for pneumograms, these devices provide valuable information to clinicians and families.

Apnea↗

Infant sleep position following new AAP guidelines. American Academy of Pediatrics.

OBJECTIVE: This report examines the response of families to the American Academy of Pediatrics June 1992 recommendation that healthy term infants be put to sleep on their back or side to decrease the risk of sudden infant death syndrome. Parents at two clinics and private practices were interviewed to ascertain sleep position practices. METHODS: Parents of infants from 1 to 6 months of age who were in the waiting room for a well-child visit were eligible for study. A total of 760 interviews were conducted using a closed-ended questionnaire. Parents were asked about sleep position, positional changes during sleep, and factors that influenced their decision to position their infant prone, side, or supine. Interviews were conducted from September 1993 through April 1994. This interval was divided into two equal, 4-month time intervals. Sleep practices were compared during the first and second time periods. Differences between practice and clinic groups were measured. Groups were compared using the chi-square test, with results considered significant at P < .05. RESULTS: The number of infants placed side or supine for sleep increased significantly since the inception of the study, from 38.1% to 59.1%. Despite this increase, parents reported that the impetus for changing position came from family or the media, rather than from health professionals. Initially, the proportion of infants in private practices placed side or supine was greater than that of clinic patients. That difference disappeared by the end of the study. Prone positioning continued to be more prevalent in the 3- to 6-month-old infants than in the 1- to 3-month-old group. The majority of infants at all ages awoke in the same position that they were put to sleep. CONCLUSIONS: Side and supine positioning for sleep increased in all socioeconomic groups. A small number of infants placed side or supine for sleep are found prone on awakening. Health professionals need to increase their role in providing sleep position guidance. As the proportion of the population positioning their infants side or supine for sleep increases, it should be possible to examine the effect on the sudden infant death syndrome rate.

Cross-Sectional Studies↗

Recent advances in home infant apnea monitoring.

Appropriate and effective nursing intervention is an essential element in determining how the family responds to the monitor in the home. Accurate assessment of the family system and dynamics provides the basis for a plan of care. The family's and infant's specific needs must be addressed. Careful implementation of the plan allows for changes and unexpected outcomes. Frequent evaluation of monitoring is necessary to determine if a change in the plan of care is needed. Recent changes in home apnea monitoring technology are rapidly altering the care of infants at risk for apnea and SIDS. The advent of the documented or recording monitor has the potential to demystify the events occurring while the infant is being monitored. Parents can get answers about their infant as quickly as a telephone call. The clinician can differentiate between a true and a false alarm and reassure the parents accordingly. Documenting false events and shallow-breathing alarms will potentially reduce the duration of monitoring, decreasing costs to the entire health care system. Documented monitoring is a valuable tool for nurses. For the staff nurse, clinical observation can be validated through trending and print out of events can be done at the bedside. For the advanced practice nurse, management of care can become more efficient through remote monitoring via modem. Patient teaching can be followed with immediate feedback. Monitors may assist in allaying anxiety in families who have lost children to SIDS or had an unexpected death in a previous sibling. Families may feel less anxious about having an "at risk" child in the home if the events are continuously being recorded. Length of hospital stay may decrease initially, with fewer rehospitalizations. Nursing research in these areas is necessary. Evaluating events occurring in the home may also help shed light on the enigma of SIDS. Several SIDS deaths have been recorded on documented monitors. If we can pinpoint exactly what takes place prior to and immediately after a SIDS episode, the enigma that has had physicians puzzled for so long may finally begin to unravel.

Apnea↗

Lisfranc's fracture-dislocation. An unusual case presentation.

The authors present a brief review of the literature with an unusual case presentation of Lisfranc's dislocation. The authors review the mechanism of injury, presentation, and treatment alternatives for both acute trauma-related injuries and neuropathic-related injuries to the Lisfranc's joint. The authors discuss the controversy surrounding the preferred treatment of neuropathic-associated injuries and suggest that possibly criteria may be established for fusion versus conservative care of these injuries.

Aged↗

A hirudin catching ELISA for quantitating the anticoagulant in biological fluids.

A catching ELISA has been developed that permits a quantitation of the anticoagulant hirudin in buffer, urine and plasma. In plasma hirudin can be determined in concentrations ranging from 0.2 to 25 ng/ml (2.4 X 10(-3) to 0.3 AT-U/ml), in urine between 0.8 and 200 ng/ml (0.01 and 2.4 AT-U/ml). The enzyme immunoassay allows a rapid, sensitive and reproducible quantitation of hirudin, and can thus be used to assess the pharmacokinetics of the anticoagulant in patients after parenteral and/or topic administration.

Animals↗

Quantitative enzyme-linked immunosorbent assay (ELISA) for hirudin.

A competitive ELISA assay has been developed that permits reproducible quantitation of the anticoagulant hirudin in buffer and urine. Coupling of peroxidase and hirudin was performed with the heterobifunctional reagent N-succinimidyl-3-(2-pyridyldithio)-propionate. In both solvents the lower limit of sensitivity was 8 ng hirudin/ml (0.08 AT-U) while the upper limit was 7.7 micrograms/ml (78.45 AT-U).

Animals↗