Intensity-modulated tangential beam irradiation of the intact breast.

PURPOSE: To evaluate the potential benefits of intensity modulated tangential beams in the irradiation of the intact breast. METHODS AND MATERIALS: Three-dimensional treatment planning was performed on five left and five right breasts using standard wedged and intensity modulated (IM) tangential beams. Optimal beam parameters were chosen using beams-eye-view display. For the standard plans, the optimal wedge angles were chosen based on dose distributions in the central plane calculated without inhomogeneity corrections, according to our standard protocol. Intensity-modulated plans were generated using an inverse planning algorithm and a standard set of target and critical structure optimization criteria. Plans were compared using multiple dose distributions and dose volume histograms for the planning target volume (PTV), ipsilateral lung, coronary arteries, and contralateral breast. RESULTS: Significant improvements in the doses to critical structures were achieved using intensity modulation. Compared with a standard-wedged plan prescribed to 46 Gy, the dose from the IM plan encompassing 20% of the coronary artery region decreased by 25% (from 36 to 27 Gy) for patients treated to the left breast; the mean dose to the contralateral breast decreased by 42% (from 1.2 to 0.7 Gy); the ipsilateral lung volume receiving more than 46 Gy decreased by 30% (from 10% to 7%); the volume of surrounding soft tissue receiving more than 46 Gy decreased by 31% (from 48% to 33%). Dose homogeneity within the target volume improved greatest in the superior and inferior regions of the breast (approximately 8%), although some decrease in the medial and lateral high-dose regions (approximately 4%) was also observed. CONCLUSION: Intensity modulation with a standard tangential beam arrangement significantly reduces the dose to the coronary arteries, ipsilateral lung, contralateral breast, and surrounding soft tissues. Improvements in dose homogeneity throughout the target volume can also be achieved, particularly in the superior and inferior regions of the breast. It remains to be seen whether the dosimetric improvements achievable with IMRT will lead to significant clinical outcome improvements.

Breast↗

Planning, delivery, and quality assurance of intensity-modulated radiotherapy using dynamic multileaf collimator: a strategy for large-scale implementation for the treatment of carcinoma of the prostate.

PURPOSE: To improve the local control of patients with adenocarcinoma of the prostate we have implemented intensity modulated radiation therapy (IMRT) to deliver a prescribed dose of 81 Gy. This method is based on inverse planning and the use of dynamic multileaf collimators (DMLC). Because IMRT is a new modality, a major emphasis was on the quality assurance of each component of the process and on patient safety. In this article we describe in detail our procedures and quality assurance program. METHODS AND MATERIALS: Using an inverse algorithm, we have developed a treatment plan consisting five intensity-modulated (IM) photon fields that are delivered with DMLC. In the planning stage, the planner specifies the number of beams and their directions, and the desired doses for the target, the normal organs and the "overlap" regions. Then, the inverse algorithm designs intensity profiles that best meet the specified criteria. A second algorithm determines the leaf motion that would produce the designed intensity pattern and produces a DMLC file as input to the MLC control computer. Our quality assurance program for the planning and treatment delivery process includes the following components: 1) verification of the DMLC field boundary on localization port film, 2) verification that the leaf motion of the DMLC file produces the planned dose distribution (with an independent calculation), 3) comparison of dose distribution produced by DMLC in a flat phantom with that calculated by the treatment planning computer for the same experimental condition, 4) comparison of the planned leaf motions with that implemented for the treatment (as recorded on the MLC log files), 5) confirmation of the initial and final positions of the MLC for each field by a record-and-verify system, and 6) in vivo dose measurements. RESULTS: Using a five-field IMRT plan we have customized dose distribution to conform to and deliver 81 Gy to the PTV. In addition, in the overlap regions between the PTV and the rectum, and between the PTV and the bladder, the dose is kept within the tolerance of the respective organs. Our QA checks show acceptable agreement between the planned and the implemented leaf motions. Correspondingly, film and TLD dosimetry indicates that doses delivered agrees with the planned dose to within 2%. As of September 15, 1996, we have treated eight patients to 81 Gy with IMRT. CONCLUSION: For complex planning problems where the surrounding normal tissues place severe constraints on the prescription dose, IMRT provides a powerful and efficient solution. Given a comprehensive and rigorous quality-assurance program, the intensity-modulated fields can be efficaciously and accurately delivered using DMLC. IMRT treatment is now ready for routine implementation on a large scale in our clinic.

Adenocarcinoma↗

Conformal radiation treatment of prostate cancer using inversely-planned intensity-modulated photon beams produced with dynamic multileaf collimation.

PURPOSE: To implement radiotherapy with intensity-modulated beams, based on the inverse method of treatment design and using a multileaf collimation system operating in the dynamic mode. METHODS AND MATERIALS: An algorithm, based on the inverse technique, has been integrated into the radiotherapy treatment-planning computer system in our Center. This method of computer-assisted treatment design was used to derive intensity-modulated beams to optimize the boost portion of the treatment plan for a patient with a T1c cancer of the prostate. A dose of 72 Gy (in 40 fractions) was given with a six-field plan, and an additional 9 Gy (in five fractions) with six intensity-modulated beams. The intensity-modulated fields were delivered using dynamic multileaf collimation, that is, individual leaves were in motion during radiation delivery, with the treatment machine operating in the clinical mode. Exhaustive quality assurance measurement and monitoring were carried out to ensure safe and accurate implementation. RESULTS: Dose distribution and dose-volume histogram of the "inverse method" boost plan and of the composite (72 Gy primary + 9 Gy boost) plan were judged clinically acceptable. Compared to a manually designed boost plan, the inverse treatment design gave improved conformality and increased dose homogeneity in the planning target volume. Film and ion chamber dosimetry, performed prior to the first treatment, indicated that each of the six intensity-modulated fields was accurately produced. Thermoluminescent dosimeter (TLD) measurements performed on the patient confirmed that the intended dose was delivered in the treatment. In addition, computer-aided treatment-monitoring programs assured that the multileaf collimator (MLC) position file was executed to the specified precision. In terms of the overall radiation treatment process, there will likely be labor savings in the planning and the treatment phases. CONCLUSIONS: We have placed into clinical use an integrated system of conformal radiation treatment that incorporated the inverse method of treatment design and the use of dynamic multileaf collimation to deliver intensity-modulated beams. The system can provide better treatment design, which can be implemented reliably and safely. We are hopeful that improved treatment efficacy will result.

Humans↗

Dosimetric verification of intensity-modulated fields.

The optimization of intensity distributions and the delivery of intensity-modulated treatments with dynamic multi-leaf collimators (MLC) offer important improvements to three-dimensional conformal radiotherapy. In this study, a nine-beam intensity-modulated prostate plan was generated using the inverse radiotherapy technique. The resulting fluence profiles were converted into dynamic MLC leaf motions as functions of monitor units. The leaf motion pattern data were then transferred to the MLC control computer and were used to guide the motions of the leaves during irradiation. To verify that the dose distribution predicted by the optimization and planning systems was actually delivered, a homogeneous polystyrene phantom was irradiated with each of the nine intensity-modulated beams incident normally on the phantom. For each exposure, a radiographic film was placed normal to the beam in the phantom to record the deposited dose. The films were calibrated and scanned to generate 2-D isodose distributions. The dose was also calculated by convolving the incident fluence pattern with pencil beams. The measured and calculated dose distributions were compared and found to have discrepancies in excess of 5% of the central axis dose. The source of discrepancies was suspected to be the rounded edges of the leaves and the scattered radiation from the various components of the collimation system. After approximate corrections were made for these effects, the agreement between the two dose distributions was within 2%. We also studied the impact of the "tongue-and-groove" effect on dynamic MLC treatments and showed that it is possible to render this effect inconsequential by appropriately synchronizing leaf motions. This study also demonstrated that accurate and rapid delivery of realistic intensity-modulated plans is feasible using a dynamic multi-leaf collimator.

Biophysical Phenomena↗

Testing of dynamic multileaf collimation.

It has been shown that intensity-modulated fields have the potential to deliver optimum dose distributions, i.e., high dose uniformity in the target and lower doses in the surrounding critical organs. One way to deliver such fields is by using dynamic multileaf collimation (DMLC). This capability is already available in research mode on some treatment machines. While much effort has been devoted to developing algorithms for DMLC, the mechanical reliability of this new treatment delivery mode has not been fully studied. In this work, we report a series of tests designed to investigate the mechanical aspects of DMLC and their implications on dosimetry. Specifically, these tests were designed to examine (1) the stability of leaf speed, (2) the effect of lateral disequilibrium on dose profiles between adjacent leaves, (3) the significance of acceleration and deceleration of leaf motion, (4) the effect of positional accuracy and rounded-end of the leaves, and (5) create a simple test pattern that may serve as a basis for routine quality assurance checks. Results of these tests are presented. The implications on dosimetry and consideration for the design of leaf motion are discussed.

Humans↗

Dose calculation for photon beams with intensity modulation generated by dynamic jaw or multileaf collimations.

A dose calculation algorithm has been developed for photon beams with intensity modulation generated by dynamic jaw or multileaf collimations. First, an in-air fluence distribution is constructed based on the dynamic motion of the jaws or leaves, taking into account the variation of output with field size defined by the jaws. The fluence distribution is then convolved with the appropriate pencil beam kernel to give correction factors which are used to calculate the dose distribution for an intensity-modulated photon field. The proposed algorithm is strictly valid in homogeneous media only, patient heterogeneity correction is accounted for in an approximate manner. Dose distributions at several depths and for several field sizes were calculated for 6- and 15-MV x-ray beams for a set of standard wedges produced by dynamic jaws. Measurements were made with film and an ion chamber. Comparisons between calculated and measured data show good agreement (within 2%) for both dose profiles and wedge factors. Similar calculations and measurements were also made for a 25-MV intensity-modulated photon field produced by dynamic motion of a multileaf collimator. Agreement between calculations and measurements is also good (within 3%). The "tongue-and-groove" effect associated with a multileaf collimator design is also examined using a ring-shaped field produced by matching two component fields. The computation time for a dynamic-collimated field is the same as that for an irregular field shaped by conventional blocks. The algorithm is applicable to any pattern of jaw or multileaf motions. The strengths and remaining problems of the algorithm are discussed.

Algorithms↗