Development of monoclonal antibodies that inhibit platelet adhesion or aggregation as potential anti-thrombotic drugs.

Cardiovascular disease is the major cause of mortality in Western countries. Platelets play a crucial role in the development of arterial thrombosis and other pathophysiologies leading to clinical ischemic events. In the damaged vessel wall, platelets adhere to the subendothelium through an interaction with von Willebrand factor (VWF), which forms a bridge between subendothelial collagen and the platelet receptor glycoprotein (GP) Ib/IX/V. This reversible adhesion allows platelets to roll over the damaged area, decreasing their velocity and resulting in strong platelet activation. This leads to the conformational activation of the platelet GPIIb/IIIa receptor, fibrinogen binding and finally to platelet aggregation. As each interaction (collagen-VWF, VWF-GPIb and GPIIb/IIIa-fibrinogen) plays an essential role in primary haemostasis, loss of either of these interactions results in a bleeding diathesis, implying that interfering with these interactions might result in an anti-thrombotic effect. Whereas GPIIb/IIIa antagonists indeed are effective anti-thrombotics, it has been suggested that drugs which block the initial steps of thrombus formation (collagen-VWF or VWF-GPIb interaction) might have advantages over the ones that merely inhibit platelet aggregation. In this review we will discuss and compare the development of monoclonal antibodies (moAbs) that inhibit platelet adhesion or platelet aggregation. The effect of the moAbs in in vitro experiments, in in vivo models and in clinical trials will be described. Benefits, limitations, current applications and the future perspectives in the development of antibodies for each target will be discussed.

Animals↗

Compression and reconstruction of sorted PET listmode data.

BACKGROUND: In nuclear medicine data can be stored in histogram or listmode format. The most popular histogram format is the planar projection format. Due to the increase in detector blocks, the improved energy resolution and the trends towards time of flight, dynamic and gated imaging, it can be more appropriate to store the data in listmode format. The size of the storage in this format increases linearly with the number of properties (positions, energy, time info) while the histogram format increases exponentially. However, the datasize of listmode data also increases linearly with the number of coincidences. Due to the high number of counts in 3D PET this will lead to very large datasets. Therefore a good compression algorithm for listmode data is very important. METHODS: A sorting and compression method is proposed to reduce the amount of space needed to store the listmode dataset. One event is represented by one number without any information loss compared to the original listmode file. The next step is to sort all events into an array of increasing numbers. These data are compressed by the gzip routine. One of the advantages of 3D PET listmode reconstructions is that they result in a more uniform resolution across the field of view (FOV), which is not always true for other reconstruction algorithms. This improved resolution is shown for the listmode data of a gamma camera operating in PET mode. RESULTS: First the effect of positional accuracy in the listmode dataset is evaluated by comparing resolution in the reconstructions. It is shown that the highest accuracy is not necessary and a significant reduction in the size of the dataset can be obtained prior to lossless compression. A further reduction can be obtained by using the proposed sorting and compression techniques. It is shown that the storage space decreases linearly with the logarithm of the number of coincidences. The compression obtained by different acquisition matrices was compared. Finally it is shown that the 3D listmode reconstruction of sorted listmode data is faster because of improved cache behaviour. The method can be applied to any kind of listmode data. The compression factors will improve when the ratio of measured events to possible events increases.

Algorithms↗

GATE: a simulation toolkit for PET and SPECT.

Monte Carlo simulation is an essential tool in emission tomography that can assist in the design of new medical imaging devices, the optimization of acquisition protocols and the development or assessment of image reconstruction algorithms and correction techniques. GATE, the Geant4 Application for Tomographic Emission, encapsulates the Geant4 libraries to achieve a modular, versatile, scripted simulation toolkit adapted to the field of nuclear medicine. In particular, GATE allows the description of time-dependent phenomena such as source or detector movement, and source decay kinetics. This feature makes it possible to simulate time curves under realistic acquisition conditions and to test dynamic reconstruction algorithms. This paper gives a detailed description of the design and development of GATE by the OpenGATE collaboration, whose continuing objective is to improve, document and validate GATE by simulating commercially available imaging systems for PET and SPECT. Large effort is also invested in the ability and the flexibility to model novel detection systems or systems still under design. A public release of GATE licensed under the GNU Lesser General Public License can be downloaded at http:/www-lphe.epfl.ch/GATE/. Two benchmarks developed for PET and SPECT to test the installation of GATE and to serve as a tutorial for the users are presented. Extensive validation of the GATE simulation platform has been started, comparing simulations and measurements on commercially available acquisition systems. References to those results are listed. The future prospects towards the gridification of GATE and its extension to other domains such as dosimetry are also discussed.

Computer Simulation↗

Validation of the GATE Monte Carlo simulation platform for modelling a CsI(Tl) scintillation camera dedicated to small-animal imaging.

Monte Carlo simulations are increasingly used in scintigraphic imaging to model imaging systems and to develop and assess tomographic reconstruction algorithms and correction methods for improved image quantitation. GATE (GEANT4 application for tomographic emission) is a new Monte Carlo simulation platform based on GEANT4 dedicated to nuclear imaging applications. This paper describes the GATE simulation of a prototype of scintillation camera dedicated to small-animal imaging and consisting of a CsI(Tl) crystal array coupled to a position-sensitive photomultiplier tube. The relevance of GATE to model the camera prototype was assessed by comparing simulated 99mTc point spread functions, energy spectra, sensitivities, scatter fractions and image of a capillary phantom with the corresponding experimental measurements. Results showed an excellent agreement between simulated and experimental data: experimental spatial resolutions were predicted with an error less than 100 microns. The difference between experimental and simulated system sensitivities for different source-to-collimator distances was within 2%. Simulated and experimental scatter fractions in a [98-182 keV] energy window differed by less than 2% for sources located in water. Simulated and experimental energy spectra agreed very well between 40 and 180 keV. These results demonstrate the ability and flexibility of GATE for simulating original detector designs. The main weakness of GATE concerns the long computation time it requires: this issue is currently under investigation by the GEANT4 and the GATE collaborations.

Animals↗

New approaches for antithrombotic antiplatelet therapies.

Cardiovascular diseases are one of the major causes of mortality in the western world. As platelet dependent thrombosis is of central importance in their pathophysiology, several successful strategies, targeting a specific platelet function or interaction, have been developed to prevent or treat these disorders. However, as the current antiplatelet strategies are limited in efficacy and safety, and often influence normal haemostatic functions, new compounds are being developed with improved characteristics. This review deals with the development of novel antiplatelet compounds for which evidence is available on their antithrombotic action in vivo. In a first part, these compounds, their targets and their potential applicability are discussed. The second part of this review focuses on BT tests and bleeding models and their usefulness for determination and/or prediction of the safety of novel antiplatelet compounds.